MN1YKAP, EMAS, miniature switch protective cover, MN1 a MN2
MN1YKAP EMAS – miniature switch protective cover. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS MN1 plastic miniature limit switches with changeover contact. Choose by actuating element.
MN1YKAP EMAS – miniature switch protective cover. Technical parameters, application and compatibility check.
BS1012E EMAS – snap-action push-button switch, plunger, 1 NO + 1 NC, snap action. Technical parameters, application and compatibility check.
TE-BS1012E EMAS – snap-action switch with bracket for control cabinet door sensing, plunger, 1 NO + 1 NC, snap action. Technical parameters, application and compatibility check.
MN1PUM1 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1KIM1 EMAS – miniature limit switch, MN1, lever, 1 CO. Technical parameters, application and compatibility check.
MN1KIM2 EMAS – miniature limit switch, MN1, lever, 1 CO. Technical parameters, application and compatibility check.
MN1PUM7 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN2MIM1 EMAS – miniature limit switch, MN2, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN1MIM1 EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
MN1MIM2 EMAS – miniature limit switch, MN1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN1MIM1Y EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
MN1PUM3 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1PUM9 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1MUM8 EMAS – miniature limit switch, MN1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN2MUM3 EMAS – miniature limit switch, MN2, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1PUM9U EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1MUM3 EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
Prices include the recycling fee.
The MN1 series combines miniature mechanical sensing with a choice of different actuators. In the design, separate three questions: how the cam actuates the switch, how the wires are connected and how the finished assembly will be protected in the given environment. Adding a protective part may solve part of the mounting, but does not by itself prove the suitability of the whole unit for water, dust or cleaning.
The public TECHNOLINE listing includes MN1MIM1Y. The EMAS sheet confirms a plastic miniature switch with a short metal roller lever and contact 1CO. Therefore record the body and actuator materials separately when selecting.
For the specific model, the manufacturer distinguishes IP20 and the version with a protective cover marked IP40. Do not automatically transfer this information to any combination of body, accessories and cable. Before ordering, check the exact compatible cover and mounting conditions for the required assembly.
Add the diagram of the changeover contact and its reference state to the documentation. One changeover can provide opposite information relative to the common contact, but does not replace two electrically independent paths. When replacing, mark the wires according to the actual terminals and compare the diagrams of the original and new product.
When looking for a weak or unstable signal, divide the circuit into mechanics, contact, lead and input. Assign each its own verification question: did the required movement take place, does the contact match the load, is the lead intact and does the input evaluate the correct state? This procedure helps prevent random replacements without finding the cause.
For a model control circuit, consider a copper line with a total current path length of 10 m, a cross-section of 1 mm² and a chosen resistivity of 0.0175 Ω·mm²/m. The line resistance is R = 0.0175 × 10 / 1 = 0.175 Ω. At a model current of 0.05 A, the voltage drop is 0.00875 V, i.e. 8.75 mV.
The length already includes the outgoing and return path. If it were a one-way cable length of 10 m, the current path would have to be doubled and the drop would be 17.5 mV. The figures are the author's calculation of an ideal line; they are not a parameter of MN1MIM1Y nor confirmation of the suitability of its contact for 50 mA.
The result does not include joints, the change of resistance with temperature or drops across other components. However, it shows that it is important to define the circuit length correctly and to distinguish the calculated drop on the conductor from an unverified property of the contact or input.
Plan the space for the wires before fastening the switch. The connection should not be exposed to excessive pull; protection of the leads and the mounting location is also covered by OMRON guidelines for basic switches. The specific terminal design and tightening follow the documentation of MN1.
After assembly, check the working movement of the cam and the return of the actuator, and keep a reference photo of the connection. A common mistake is to add a cover afterwards without checking the space for the wires, or to confuse terminal protection with sealing of the entire installation.
No. You also need identical or suitably adapted fastening, actuator, connection and operating range.
To compare the metal version, visit Metal Limit Switches MN3. Another plastic variant is offered by Plastic Limit Switches MK1; confirm interchangeability with specific drawings.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.