Contactless monitoring of a protective guard makes it possible to separate the sensor on the fixed part from the counterpart on the door. However, selection does not start with the largest distance stated in the catalogue. First determine which guard positions the system must recognise, which movements the mechanics allow and how the information will be evaluated. The magnetic principle alone does not say whether a specific product meets the requirements of a particular safety function.
Sensor, counterpart and evaluation belong together
On its page about magnetic safety switches the manufacturer PILZ describes guard monitoring as a system of sensor and evaluation. This is an explanation of the principle; when purchasing, check the exact assembly of the specific product offered.
In the selection sheet, write down the order designation of both parts, the connection version, the required output logic and the relevant evaluation unit. In addition to the wiring diagram, you need the mounting conditions. Ask separately for which counterpart orientation the stated distances apply and what tolerances the manufacturer allows for lateral offset. Photographic similarity of two housings does not replace such information.
The operating gap is a spatial problem
When preparing the mounting, draw local coordinates: the distance between the faces, offset along the door and offset across it. Add the rotation of the counterpart to them. This helps describe a fault more precisely than the note "sometimes does not switch". Also record the door position during measurement, because an unloaded guard and a guard supported by a latch can create different geometry.
A preliminary check can be done on the mounting drawing, but final verification belongs on the finished assembly according to its instructions. When looking for the cause, always change one position at a time and record the result. Random shifting of both parts at the same time may hide whether the original problem was caused by the hinge, the bracket or the setting itself.
Author's example: two tolerances, two reserves
In a practice design, consider a target face gap of 3.0 mm. The model deviation of the frame is ±0.4 mm and of the bracket ±0.3 mm. The largest gap is 3.7 mm, the smallest 2.3 mm. If the designer sets an operating window of 2.0 to 4.0 mm for this calculation, a reserve of 0.3 mm remains on both sides.
All values including the operating window are the author's own; they are not a sensor parameter or a determination of a safe distance. Adding a further model play of ±0.5 mm widens the interval to 1.8 to 4.2 mm and violates the original condition. The calculation shows why it is not enough to set the correct gap only when the new door is first closed.
Mounting record and typical mistakes
Keep a reference photo, bracket dimensions and the checked door states. When repairing hinges or replacing the counterpart, return to these data and the prescribed functional test. A common mistake in selection is to leave the evaluation compatibility unfilled or to confuse magnetic door holding with documented protective guard locking.
Can a different magnet be used instead of the prescribed counterpart?
Do not regard such a replacement as a verified assembly. Ask the manufacturer for confirmation of the specific combination and then verify its function.
Does a contactless design guarantee a certain level of safety?
No. The required properties are assessed within the entire machine function. The selection context can be found in the category Safety Limit Switches; a mechanical alternative is represented by Key-Operated Safety Switches - without Electrical Locking.