Greego Circuit Breakers

Gregoo 8CB series miniature circuit breakers with D characteristic for circuits with high inrush currents – motors, transformers and power supplies. Choose by rated current and number of poles; an auxiliary contact is available.

Filters
Found 5 products
OUR TIP IN STOCK

8CB11010D, Gregoo, miniature circuit breaker, 1P, 10A, characteristic D, 10kA

Cat. no.: 8CB11010D

8CB11010D, Gregoo: miniature circuit breaker 1P/10A with tripping characteristic D and declared breaking capacity 10kA.

In stock 3 ks
1,93 €
excl. VAT · 2,33 € incl. VAT
OUR TIP IN STOCK

8CBMCB-L7, Gregoo, auxiliary contact for Gregoo circuit breakers, NO and NC contact, 4 A

Cat. no.: 8CBMCB-L7

8CBMCB-L7 Gregoo – auxiliary contact for Gregoo circuit breakers, NO and NC contact, 4 A. Exact technical data for selecting the miniature circuit breaker type.

In stock 5 or more pcs
3,73 €
excl. VAT · 4,51 € incl. VAT
OUR TIP IN STOCK

8CB30610D, Gregoo, miniature circuit breaker 3P, 6A, characteristic D, 10kA

Cat. no.: 8CB30610D

8CB30610D, Gregoo, miniature circuit breaker 3P, 6A, characteristic D, 10kA. The three-pole miniature circuit breaker GREGOO 8CB30610D with rated current 6A and characteristic D is designed to…

In stock 5 or more pcs
4,60 €
excl. VAT · 5,56 € incl. VAT
OUR TIP IN STOCK

8CB31610D, Gregoo, miniature circuit breaker, 3P, 16A, characteristic D, 10kA

Cat. no.: 8CB31610D

8CB31610D, Gregoo: miniature circuit breaker 3P/16A with tripping characteristic D and declared breaking capacity 10kA.

In stock 5 or more pcs
4,60 €
excl. VAT · 5,56 € incl. VAT
OUR TIP IN STOCK

8CB32010D, Gregoo, miniature circuit breaker, 3P, 20A, characteristic D, 10kA

Cat. no.: 8CB32010D

8CB32010D, Gregoo: miniature circuit breaker 3P/20A with tripping characteristic D and declared breaking capacity 10kA.

In stock 5 or more pcs
4,60 €
excl. VAT · 5,56 € incl. VAT

Prices include the recycling fee.

Greego circuit breakers

The category groups circuit breakers 8CB11010D, 8CB30610D, 8CB31610D and 8CB32010D and auxiliary contact 8CBMCB-L7. When ordering, use the full code of the specific item. For a service replacement, compare the rating plate of the original device, the number of poles and the required accessory function. The similarity of the designation alone may not mean an identical version.

D characteristic and actual circuit conditions

Greegoo manufacturer documentation for 8CB states overload and short-circuit protection, a breaking capacity of 10 kA and, for the D characteristic, a magnetic release band of 10 to 20 times the rated current. This multiple refers to the fast response to overcurrent, not to the permissible continuous consumption.

Choose the characteristic according to the operating currents, the load start-up and the tripping conditions. The increased current at start-up must be assessed together with its duration. At the same time, it is necessary to verify whether the fault current at the end of the cable is sufficient for the required disconnection. The D designation alone does not guarantee suitability for any motor or transformer.

A circuit breaker protects the circuit within a specific design. It does not automatically replace separate motor overload protection or an RCD. Address the required protective functions and their coordination in the context of the whole installation; a guide is offered by the categories Circuit breakers and RCDs.

Model example: the current multiple is not enough

For the author's example, let us choose a hypothetical circuit breaker D10 and use the stated band. Its conversion gives 10 × 10 = 100 A to 20 × 10 = 200 A. A model inrush current of 80 A corresponds to eight times the rated current; a model fault current of 150 A corresponds to fifteen times.

The first value lies below the stated band, the second within it. Neither result determines the disconnection time without the time profile and the complete tripping characteristic. The example is not a product recommendation or proof of safe protection. The design requires the actual current conditions, cable conditions and documentation corresponding to the supplied device.

Choice of poles and assembly check

In the details of 8CB11010D you will find a single-pole version; 8CB31610D is listed as three-pole. For a multi-phase feeder, verify common operation of the required poles and the function of the individual conductors. The number of poles does not say how the neutral conductor of the whole installation is to be handled.

When replacing, also compare the connection points, dimensions and the possibility of fitting accessories. A similar cover or the same current does not confirm interchangeability. Do not transfer parameters of another series to 8CB and always relate the general series catalogue to the specific order code and version.

Auxiliary contact and commissioning

8CBMCB-L7 is a separate accessory item. For the design of the signalling branch, obtain the diagram, permissible voltage, load for the given type of current and confirmation of mechanical compatibility. The contact current rating alone does not describe all switching conditions.

Mounting is carried out by a qualified person in a secured de-energised state. They check the fixing, conductors and their terminations, terminals according to the manufacturer's instructions and the space in the control cabinet. The functional check should also include signalling and the agreement of the actual state with the labels. An auxiliary signal cannot be used as proof of absence of voltage.

In the event of an unexpected trip, record the time, the active loads and the relationship to equipment start-up. Professional diagnostics should distinguish an operating overload from a fault and check the connections. Replacement with a higher current value can only be considered after recalculating the circuit, not as a means of eliminating nuisance tripping.

FAQ

Does the 10 kA figure mean the permissible operating current?

No. The breaking capacity and rated current are different quantities; each is verified against a different requirement of the circuit.

Does the auxiliary contact prove the cause of tripping?

Only if its specific function explicitly allows it. Position information cannot automatically be presented as separate signalling of a fault trip.