Phone +420 774 723 123 Cart · 0 · empty

Special relays

EMAS and CHANA special relays – voltage and phase monitoring relays, level relays, bistable (impulse) relays and multifunction timer relays. Choose by function, supply and contact rating.

Filters
Found 8 products
OUR TIP IN STOCK

RR3VP01, EMAS, voltage monitoring relay, 1f, 220VAC, 1CO

Cat. no.: RR3VP01

EMAS RR3VP01 is used to monitor the voltage of a single-phase system. The model is powered by 220VAC and provides one changeover contact output 1CO.

In stock 5 or more pcs
13,30 €
excl. VAT · 16,10 € incl. VAT
OUR TIP IN STOCK

RR3VP02, EMAS, voltage monitoring relay, 3f, 380VAC, 1CO

Cat. no.: RR3VP02

EMAS RR3VP02 is used to monitor the voltage of a three-phase system. The model is powered by 380VAC and provides one changeover contact output 1CO.

In stock 5 or more pcs
13,71 €
excl. VAT · 16,59 € incl. VAT
IN STOCK

Staircase relay, 230V AC, 16A, EKT8-LS-230VA, CHANA

Cat. no.: EKT8-LS-230VA

It is controlled by one or more push buttons. Intended for switching lights. After pressing the button, the output contact closes for the set time. Time setting range 0.5s - 20 minutes.

In stock 5 or more pcs
15,92 €
excl. VAT · 19,27 € incl. VAT
IN STOCK

EKT8-ST-230A, CHANA, star–delta time relay, 230VAC, 2CO/16A, DIN

Cat. no.: EKT8-ST-230A

EKT8-ST-230A is a CHANA time relay for star–delta motor starting. It operates from 230VAC and provides two changeover contacts 16A with adjustable star time and switchover delay.

In stock 5 or more pcs
15,92 €
excl. VAT · 19,27 € incl. VAT

EKM8-01-12-240VAD, CHANA, memory pulse relay, 12–240VAC/DC, 16A, 1NO, DIN

Cat. no.: EKM8-01-12-240VAD

EKM8-01-12-240VAD is a CHANA memory pulse relay for push-button control. TECHNOLINE specifies a wide control voltage of 12–240VAC/DC, contact 1NO/16A and retention of the last state during a power…

On request
15,92 €
excl. VAT · 19,27 € incl. VAT

EKLT001, CHANA, pulse relay 230VAC, 16A, 1NO, DIN 35mm

Cat. no.: EKLT001

EKLT001 is a CHANA pulse relay for controlling lighting with push buttons from several places. After each control pulse, the output contact switches to the opposite state.

On request
15,92 €
excl. VAT · 19,27 € incl. VAT

EKL8-01-24-240VAD, CHANA, level relay, 24–240VAC/DC, 1CO/10A, delay 0.1–10s

Cat. no.: EKL8-01-24-240VAD

EKL8-01-24-240VAD is a CHANA level relay for evaluating the liquid level using connected probes. It has a 24–240VAC/DC power supply and a changeover relay output.

On request
15,92 €
excl. VAT · 19,27 € incl. VAT

Prices include the recycling fee.

Special relays

Choose special relays according to the event the device is to evaluate or create: overvoltage, a change in level, the arrival of a pulse or the expiry of a time. They are not interchangeable versions of a standard switching relay. The same width on the DIN rail or a similar current rating does not guarantee the same function, power supply or response after switching on.

What tasks the range covers

The category includes EMAS voltage relays RR3VP01 and RR3VP02, starting EKT8-ST-230VA, level EKL8-01-24-240VAD, pulse EKLT001, memory and pulse EKM8-01-12-240VAD, staircase EKT8-LS-230VA and cycling EKT8-S1-12-240VAD relays from CHANA.

Voltage monitoring and contact load

A voltage relay compares the monitored quantity with the set limits and passes the result to an output contact. The user chooses how long a deviation must last before it triggers a response. A delay that is too short can cause unwanted tripping during transients; a delay that is too long leaves the equipment outside the required conditions longer than the process allows.

For RR3VP01 EMAS datasheet specifies one changeover contact and 10 A for a resistive load.

Such a value does not automatically mean suitability for directly switching a motor or LED load of the same size. Separately check the switched voltage, the nature of the load, the inrush current and the switching frequency. For three-phase monitoring, the diagram must define which voltage is actually measured; the number of phases alone does not prove that their sequence is monitored.

Level and starting control

EKL8-01-24-240VAD offers control of one or two levels, selection of pump on or off, adjustable sensitivity and output delay.

Two levels allow a working band to be created between starting and stopping. Position the probes with regard to waves and inflow; incorrect evaluation can cause repeated switching. Before choosing, verify that the measuring principle is suitable for the specific liquid and sensing conditions. The sensitivity setting cannot replace properly designed probes.

EKT8-ST-230VA has separate settings for the star time and the transition delay.

When designing a star/delta starter, assess the entire start-up: the suitability of the motor, the contactors, their interlocking and the drive load. The time relay creates the control sequence; it is not a power starter itself or a replacement for motor protection. The transition time must respect the actual drop-out and pick-up of the contactors used.

Pulse, run-on and regular cycle

Pulse control is suitable where a short command changes a lasting state. The staircase function, on the other hand, works with time-limited switching on. For cycling, you need to define the length of the active and inactive period and which period the sequence starts with. When selecting, also describe the effect of pressing the button again while the time is running; it must match the functional diagram of the selected variant.

U EKT8-S1-12-240VAD modes starting with a pulse or a pause are specified. Compare other time functions in the category Time relays and counters.

Model calculation of cycling load

Consider a model sequence with 15 seconds on and 45 seconds off. The period is 60 seconds and the on-ratio is 15 / 60 = 25 %. In one hour there are 3600 / 60 = 60 cycles, and 480 cycles during an eight-hour shift. Each contains a make and a break, i.e. 960 state changes. This is the basis for assessing the switching frequency; the contact life cannot be calculated from the stated times without knowing the load. This is our own model, not the parameters of a specific application.

The control input may evaluate a short pulse, a rising edge or a sustained level. Therefore, draw the timing diagram of the command and the required output in the design. Include the situation where the button remains pressed or the command is repeated before the set interval has expired. Two relays with the same time range may behave differently in these situations.

What to check before ordering

  • Separate the device power supply, the measuring input and the switched circuit; they may have different requirements.
  • Check the time range, triggering method, reset and behaviour after a power interruption.
  • Compare the contact arrangement with the required idle and active state.
  • Include wire marking, accessibility of the controls and the possibility of a functional test.

FAQ

Is the set time also protection against a hazardous state?

Not by itself. Process automation and safety functions have different requirements. The protective functions of the machine must be based on its own safety solution.

Can a relay be replaced based only on the current stated in its name?

No. The control voltage, functional sequence, contacts and permitted load must also match. Assess DC and inductive circuits separately.

How to verify correct function?

Prepare a test of a normal command, a repeated command during the cycle and the return of power. Record the actual output state; the indicator LED alone does not prove that the entire load is correctly connected.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.