Phone +420 774 723 123 Cart · 0 · empty

Bells and Bell Transformers

CHANA EKEB bells and EKBT bell transformers for DIN rail. Choose by voltage and transformer power.

Filters
Found 2 products
IN STOCK

EKEB, CHANGAN, bell, 24V AC, 50 Hz, , CHANA

Cat. no.: EKEB

EKEB CHANGAN – bell, 24V AC, 50 Hz, , CHANA. Key data: 24 V AC. Exact technical data for selecting the bell device type.

In stock 4 ks
1,93 €
excl. VAT · 2,33 € incl. VAT
IN STOCK

EKBT, CHANGAN, bell transformer, 230/8, 12, 24V AC, 8VA, , CHANA

Cat. no.: EKBT

EKBT CHANGAN – bell transformer, 230/8, 12, 24V AC, 8VA, , CHANA. Key data: 230 V AC, taps 8, 12, 24V AC, 24 V AC. Exact technical data for selecting the bell device type.

In stock 2 ks
5,85 €
excl. VAT · 7,08 € incl. VAT

Prices include the recycling fee.

Doorbells and bell transformers

A bell transformer is selected according to the supply requirements of the bell or the downstream system. A matching voltage figure is not enough: the AC or DC designation, the required power and the operating mode are also important. The range includes, for example, the EKBT CHANA bell transformer with the commercial designation 230/8-12-24 V AC and 8 VA. Assess each output option according to the documentation of the specific version.

The bell and the transformer perform different functions

The range is complemented by the EKEB CHANA bell itself. The bell produces an acoustic signal, the transformer provides the appropriate supply. The same brand or a shared category does not by itself confirm that a specific pair can be connected without further assessment. Compare the voltage, type of current, consumption and permissible operating mode. For the bell, also consider the mounting location and the required audibility; the acoustic parameters must be based on the specific product, not on the power of the supply transformer.

First determine the requirements of the appliance

From the specification of the powered equipment, determine the rated voltage, its tolerance, the type of current and the power or current consumption. A traditional bell load and an electronic device may not have the same supply conditions. An AC output is not automatically a suitable substitute for a required DC supply, even if the numerical voltage value is the same.

In the transformer data sheet, check the primary voltage, secondary values and rated power separately. The data are broken down in this way, for example, in the primary documentation of ETEK bell transformers. When selecting, it is necessary to work with the data sheet of the exact product supplied; a similar type designation by itself does not determine its properties.

What power in VA means

The volt-ampere expresses the apparent power of an AC circuit. The relationship S = U × I is useful for assessing current consumption, but a simple calculation does not replace the operating data of the appliance or the permissible load of a specific output. A figure in watts may not be a full substitute for a figure in VA without further information.

Several stated secondary voltages do not mean several independent sources, each of which automatically has the full rated power available. Simultaneous use of the outputs and their current limits must be described by the documentation. Supplying several appliances is therefore not solved just by counting the available terminals.

Model example of two appliances

Consider a model appliance designed for 12 V AC with a consumption of 0.25 A. Its apparent power for this brief is 12 × 0.25 = 3 VA. Two identical appliances operating simultaneously represent 6 VA. A numerical comparison with the 8 VA designation is only a first check, not a finished approval of the assembly.

Next, the permissible load of the selected output, any higher inrush consumption, the duty cycle and the influence of the wiring are assessed. If one of the devices required 12 V DC, a favourable power balance alone would not make the transformer a suitable direct supply. The example is our own calculation brief without recommending specific wiring.

Installation space and wiring behaviour

For the location, prepare suitable mounting space and circuit arrangement; choose the related DIN rails and cable trunking according to the device dimensions and the enclosure design. The mains part must be handled by a qualified person. The name “bell transformer” alone is not proof of all the protective properties of the finished installation.

For a remote appliance, the voltage drop and the operating state at its terminals are also assessed. The device may show a different voltage without load than when the bell is activated. Diagnostics therefore need known measurement conditions; choosing a higher voltage output cannot be recommended as a universal remedy for long wiring. Other installation components can be found in the overview of electrical consumables.

FAQ

Does a higher transformer power mean louder ringing?

Not automatically. Loudness and function are determined by the specific bell at the prescribed supply. A power reserve is not an instruction to increase the voltage.

Can all the listed outputs automatically be used at the same time?

No. You need documented load and simultaneous operation conditions for the specific transformer, not just a list of voltage values in the name.