Phone +420 774 723 123 Cart · 0 · empty

Crane Pendant Control Spare Parts

Spare parts for EMAS crane pendant controls: PVB contact blocks and PVTH and PVCH push button heads. Check the series, number of speed steps and contact type.

Filters
Found 6 products
−10 % OUR TIP IN STOCK

PVB1, EMAS, crane pendant control spare part, contact block START

Cat. no.: PVB1

PVB1 EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
1,84 € 2,05 €
excl. VAT · 2,23 € incl. VAT
−10 % OUR TIP IN STOCK

PVB2, EMAS, crane pendant control spare part, contact block STOP

Cat. no.: PVB2

PVB2 EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
1,84 € 2,05 €
excl. VAT · 2,23 € incl. VAT
−10 % OUR TIP IN STOCK

PVTHBD, EMAS, crane pendant control spare part, push-button head, single-speed

Cat. no.: PVTHBD

PVTHBD EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
2,84 € 3,15 €
excl. VAT · 3,43 € incl. VAT
−10 % OUR TIP IN STOCK

PVTHSD, EMAS, crane pendant control spare part, push-button head, single-speed

Cat. no.: PVTHSD

PVTHSD EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
2,84 € 3,15 €
excl. VAT · 3,43 € incl. VAT
−10 % OUR TIP IN STOCK

PVCHBD, EMAS, crane pendant control spare part, push-button head, two-speed

Cat. no.: PVCHBD

PVCHBD EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,24 € 3,60 €
excl. VAT · 3,92 € incl. VAT
−10 % OUR TIP IN STOCK

PVCHSD, EMAS, crane pendant control spare part, push-button head, two-speed

Cat. no.: PVCHSD

PVCHSD EMAS – crane pendant control spare part, PV. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,24 € 3,60 €
excl. VAT · 3,92 € incl. VAT

Prices include the recycling fee.

Spare parts for EMAS crane pendant controls

The head and the contact are different parts

The head converts the operator's press into mechanical movement, the contact block changes the electrical state of the circuit. Damage to the rubber or plastic actuator therefore does not necessarily mean a contact fault, and vice versa. The range includes blocks PVB1 and PVB2 and single- or two-speed heads PVTH and PVCH. When selecting, identify the exact component and the type of the original station.

Selection data – Spare parts for crane pendant controls

Step What to document
Identification type of the original station and the required part
Operating requirements contact function and press travel
Acceptance return, sequence of steps and core map

Keep the correct number of steps

Single-speed and two-speed control have different requirements on press travel. A similar front shape does not prove the same internal mechanism. Write down which contacts should change in the first and second step. The replacement must match the mechanical seating as well as the approved contact logic; a different part may change the sensitivity or the order of commands.

Identification before disassembly

Photograph the station's rating plate, the original part, its position and the terminal markings. Add the original circuit diagram. Do not order only by colour or arrow symbol, as these do not describe the design variant. If the marking is illegible, compare the mounting points, dimensions and number of steps, but have the final compatibility confirmed against the documentation.

Diagnosing the cause

If the head works intermittently, distinguish between mechanical sticking, a contact fault and a broken cable. If the symptom changes with a certain position of the station, the problem may be in the supply cable rather than in the button. Measurement and service procedures must respect safely isolated equipment. Replacing one block without identifying the cause may only hide the fault temporarily.

Acceptance of a repaired station

After replacement, check the return of the head, the contact sequence, the individual steps and the prescribed command interlocking. Check the seating of the wires, the strain relief of the supply cable and the closing of the enclosure. Compare the result with the original function map and record the identity of the new part. The intervention must not inadvertently change the meaning of the controls or the safety functions of the machine.

FAQ

Can I replace a contact block with another one with the same number of terminals?

The number of terminals is not enough. Check the contact function, the mechanical interface and the suitability for the specific station.

Does the name START or STOP mean a specific machine wiring?

It is a trade designation of the part. Confirm the actual function using the circuit diagram and documentation.

Related selection: Complete crane pendant controls.

Cookies on this website