Phone +420 774 723 123 Cart · 0 · empty

Limit Switch Spare Parts

Replacement actuator heads and contact blocks for EMAS limit switches. Check the switch series and head type.

Filters
Found 19 products
IN STOCK

LD33SOM101, EMAS, limit switch actuator head / actuator, spring lever, for L5

Cat. no.: LD33SOM101

LD33SOM101 EMAS – limit switch actuator head / actuator. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,20 €
excl. VAT · 3,87 € incl. VAT
IN STOCK

LD33SOP101, EMAS, limit switch actuator head / actuator, spring rod, for L5

Cat. no.: LD33SOP101

LD33SOP101 EMAS – limit switch actuator head / actuator. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,20 €
excl. VAT · 3,87 € incl. VAT
IN STOCK

LK20K13, EMAS, limit switch contact block, 1 NC + 1 NO, snap action

Cat. no.: LK20K13

LK20K13 EMAS – limit switch contact block, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,83 €
excl. VAT · 4,63 € incl. VAT
IN STOCK

LK20K23, EMAS, limit switch contact block, 1 NC + 1 NO, slow action

Cat. no.: LK20K23

LK20K23 EMAS – limit switch contact block, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

In stock 5 or more pcs
3,83 €
excl. VAT · 4,63 € incl. VAT
IN STOCK

LK20K25, EMAS, limit switch contact block, 2 NC + 1 NO, slow action

Cat. no.: LK20K25

LK20K25 EMAS – limit switch contact block, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

In stock 5 or more pcs
7,16 €
excl. VAT · 8,66 € incl. VAT
IN STOCK

LK20K27, EMAS, limit switch contact block, 1 NC + 2 NO, slow action

Cat. no.: LK20K27

LK20K27 EMAS – limit switch contact block, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.

In stock 5 or more pcs
7,16 €
excl. VAT · 8,66 € incl. VAT

Prices include the recycling fee.

Limit Switch Spare Parts

A spare part should restore the required function of a specific limit switch. It is not enough that it fits into the same housing or has a similarly sized roller. Before ordering, identify the complete assembly code, head version, contact block and reason for repair. If the damage was caused by an unsuitable approach, overtravel or ingress of dirt, replacing the worn part alone will not remove the cause.

A contact block is not interchangeable just by the number of contacts

The range includes, for example, EMAS LK20K13 and LK20K23. The manufacturer distinguishes snap action for the first and slow action for the second with the same arrangement 1NC + 1NO. The overview is confirmed by the EMAS replacement block catalogue. Matching designations of two contacts therefore do not mean the same signal course during movement.

For LK20K13 the manufacturer states compatibility with the series L1, L2, L3, L5, L51, L52, L53 and L54; see technical sheet LK20K13. This assignment is an initial check of the series, not a permission to change any contact function of the original switch. Also check the specific assembly, the mechanical actuation of the block and the equipment documentation.

The head changes the actuation geometry

The range also includes spring heads LD33SOM101, a roller head LD33MEM121 or the head LD51MEM123 with a longer lever. For a mechanical replacement, check the fastening, orientation, direction of action and operating range. A head intended for another family must not be considered compatible just because it has a similar shape or the same wheel diameter.

After changing the lever length, the relationship between the cam travel and the movement of the contact mechanism may change. The material and shape of the actuator tip also affect contact with the cam. When repairing, therefore, check the switching position, release and overtravel reserve again. Mechanical adaptation of a part outside the combinations supported by the manufacturer cannot be replaced by a mere electrical continuity check.

Model example: same number of contacts, different behaviour

Consider two model switching diagrams with uniform actuator movement at a speed of 20 mm/s. In the first, NC opens at 1.5 mm and NO closes at 2.5 mm. Between the events there is a travel of 1 mm, i.e. a time of 1 / 20 = 0.05 s during which both contacts are open. In the second diagram, NO closes at 1.5 mm and NC opens only at 2.5 mm: for the same 50 ms, both are closed instead.

These are the author's diagrams, not the actual switching positions of LK20. The example shows the difference between a gap and an overlap and explains why a "one NO and one NC" replacement can change the behaviour of the control. Before replacement, the specific diagram is compared, not just the number of contacts on the label.

Service procedure and FAQ

The repair is carried out by a qualified person after the equipment has been safely secured against unexpected movement and electrical hazard. They check the seal, cover closure, cable entry and mechanical damage to other parts. The functional test should cover the entire operating cycle. For safety use, it must be followed by the prescribed verification of the entire protective function.

To identify the original design, refer to Plastic Limit Switches IP65 and Metal Limit Switches IP65. The complete order code of the original component takes precedence over visual similarity.

Will a new block automatically restore the original degree of protection?

No. A contact block does not repair a damaged housing, seal or an unsuitably made cable entry.

Is replacing a head just a mechanical repair?

Not necessarily. A change in actuation geometry may affect the electrical sequence and the documented properties of the complete switch.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.