IS10-01-6L, SMC, pressure switch 0.1–0.6MPa, cable 3m
IS10-01-6L, SMC – mechanical pressure switch; Adjustable switching pressure: 0.1–0.6MPa; Lead wire length: 3m; Thread type: R.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
SMC pressure switches for monitoring pressure and vacuum in air lines with contact or electronic output. Choose by range, output and connection.
IS10-01-6L, SMC – mechanical pressure switch; Adjustable switching pressure: 0.1–0.6MPa; Lead wire length: 3m; Thread type: R.
PS1100-R06L-X104, SMC, electronic pressure switch, −0.1 to +0.4MPa, Ø6mm, 12–24VDC, cable with connector.
Prices include the recycling fee.
A pressure switch converts reaching a certain pressure into an electrical state. This category includes SMC IS10-01-6L, PS1100-R06L-Q and PS1100-R06L-X104. When selecting, the connection size is not enough: the measured overpressure or vacuum, the switching direction, electrical compatibility and the pressure tapping point are decisive. The signal can confirm that the pneumatic circuit is ready, but by itself does not prove the cylinder position or safe clamping of the product.
IS10 is one of the pressure switches with a reed contact. For the specific for IS10-01-6L the manufacturer specifies adjustable range 0.1–0.6 MPa and a cable of length 3 m. This setting range is not automatically the permitted range of all operating pressures or a guarantee of switching point accuracy. Always verify the electrical load of the contact according to the documentation of the specific version.
PS1100 is an electronic two-wire switch for vacuum and residual pressure. SMC catalogue for PS1100 specifies a setting of −0.1 to 0.4 MPa, switching at a pressure lower than the set value and a R06 connection for 6 mm. For the special suffix X104, do not transfer all the properties of the standard version without confirmation. Order according to the full code, not just the designation PS1100.
The two wires of an electronic switch do not mean an ordinary mechanical contact. SMC manual for PS1000/1100/1200 warns of residual current in the off state, voltage drop when switched on and the need for a correct load. It specifies a load current of 5–40 mA, a residual current of at most 1 mA and an internal voltage drop of at most 5 V. The device must therefore not be connected directly to a power supply as a standalone two-wire load; follow the manufacturer's diagram. The switch is not waterproof and has no reverse polarity protection.
When verifying compatibility, put the output and PLC input conditions side by side. A matching rated voltage is not enough. The input must reliably detect the off state even with residual current and the on state at the available voltage. If the indicator on the sensor responds correctly but the program still shows the switch as on, check exactly this combination of parameters. Randomly adding a resistor is not a substitute for proper design.
Overpressure and vacuum describe the difference relative to a reference. A value of −0.06 MPa with atmospheric reference is a difference of −60 kPa or −0.6 bar; it is not a negative absolute pressure. When comparing devices, note whether you are working with relative or absolute pressure. For vacuum gripping, see the category Vacuum ejectors.
A sensor upstream of the regulator monitors a different part of the system than a sensor at the consumer. Local drops may occur during consumption that you cannot see on a remote pressure gauge. A long, narrow measuring branch can affect the time response. Prepare the air with a suitable pneumatic air preparation unit and test the switching during the actual cycle, including the simultaneous consumption of other equipment.
Hysteresis is the difference between the state change limits when the pressure rises and falls. It is not the same as measurement accuracy or time delay. Some devices have a fixed or design-determined hysteresis; the possibility of setting the switching point does not automatically mean that both limits can be set separately.
The following is a general model of decision logic, not a setting or specification of IS10 or PS1100. Let us assume that the process is enabled when the pressure rises above 0.50 MPa and disabled when it falls below 0.45 MPa. The difference is 0.05 MPa, i.e. 0.5 bar. From an initial off state at 0.44 MPa, a rise to 0.51 MPa activates the enable; a drop to 0.48 MPa leaves it active. After a drop to 0.44 MPa it is cancelled, and a return to only 0.48 MPa is not enough for a new enable. The same value within the band therefore corresponds to different states depending on the history.
If the process needs at least 0.42 MPa, there is a reserve of 0.03 MPa between this value and the model switch-off limit. It must cover the decision uncertainty and any further drop during the machine response. Increasing the hysteresis without assessing the process may suppress switching and at the same time reduce the operating reserve. For vacuum, verify the sign and direction of the logic separately.
The switching state indicates that a condition has been met, not the entire pressure curve. For continuous recording, look for a suitable measuring output among process sensors and compare the range and time response.
Test the rise, fall, repeated cycles and restoration of power and supply. Record both actual limits and the test conditions. Ordinary pressure signalling does not replace a separately assessed safety function. Maintenance is carried out by a qualified person after safely disconnecting energy sources and verifying depressurisation.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.