Surface-Mounted Distribution Boards

NOARK and EAE surface-mounted distribution boards for circuit breakers and modular devices. Choose by number of modules, rows, protection rating and door.

Filters
Found 5 products

PHS 4T, NOARK, surface-mounted plastic distribution board, 4 modules, transparent door, IP65

Cat. no.: PHS 4T

PHS 4T, NOARK, surface-mounted plastic distribution board, 4 modules, transparent door, IP65. The wall-mounted PHS 4T version protects four modular devices in a plastic box with a transparent cover.

On request
12,98 €
excl. VAT · 15,70 € incl. VAT

PNS 24T, NOARK, wall-mounted plastic distribution board, 24 modules, transparent door, IP40

Cat. no.: PNS 24T

PNS 24T, NOARK, wall-mounted plastic distribution board, 24 modules, transparent door, IP40. The surface-mounted PNS 24T distribution board contains two rows for a total of 24 modular devices.

On request
14,45 €
excl. VAT · 17,48 € incl. VAT

Prices include the recycling fee.

Surface-mounted distribution boards

This category includes NOARK PNS 12T, PNS 24T, PNS 36T and PHS 4T as well as the metal EAE EE3S06CF. version. Surface mounting on a wall determines the position of the enclosure; it does not by itself determine the suitable environment, cabling capacity or properties of the resulting electrical assembly.

Calculate capacity by modules and rows

The NOARK PNS manufacturer table confirms PNS 12T as one row of 12 modules, PNS 24T as two and PNS 36T as three such rows. PHS 4T is a separate four-module version. The number of modules does not express the number of circuits.

Create a list of devices with their actual width and requirements for adjacent free space. Include the main switch, protective devices, any controls and accessories. A multi-pole element may occupy several modules. Besides space on the rail, you need space for conductors, connections between rows and terminations on terminals. Two rows are also not one uninterrupted long rail.

Plan which devices belong together and how the supplies will reach them. The arrangement must remain legible even after the front cover is fitted. Place the reserve where you expect expansion; free space in another row may require new conductor routing. A higher number of modules alone does not confirm the possibility of a higher current load.

Environment and scope of delivery

Assess PNS and PHS as different versions. Verify the protection rating, material and mounting conditions in the data sheet of the specific type. Transparent doors allow the state of the devices to be monitored, but say nothing about resistance to water or cleaning agents. For an outdoor location, assess solar radiation, temperature and the protection of the entries separately.

For a metal distribution board, confirm the set of rails, front covers and terminal blocks in advance. The fitting drawing must correspond to the actual delivery. Neither glazing nor the size of the enclosure means that circuit breakers are installed inside. The finished assembly needs its own wiring design and verification; the properties of an individual enclosure do not replace this step.

Author's model example: space for expansion

Consider an exclusively teaching list: six single-module devices, one four-module and two two-module devices. The occupancy is 6 + 4 + 2 × 2 = 14 modules. If we add the chosen reserve of four modules, we need 18 positions. A twelve-module distribution board is not enough in terms of space; the version with 24 modules is a candidate for further assessment. None of these values represents a recommended wiring or a parameter of a specific circuit.

Then divide the devices into rows and verify the connections, clearances and thermal load. The model does not add currents or determine protection. The reserve of four modules is only the author's assumption, not a generally prescribed size.

Mounting and checking before handover

Choose a surface and anchoring appropriate to the weight of the fitted distribution board. Before fixing, draw the cable entries and the door opening path. Prepare the holes according to the instructions and seal them with suitable elements. Conductors should not press on the cover when closing. Close unused device openings with the designated blanking plates. Entrust the electrical installation and its verification to a qualified person.

If the cover does not sit properly, first check the position of the rails, protruding conductors and correct seating of the devices. In the event of repeated tripping of protection, do not infer the cause from the size of the distribution board: it is necessary to distinguish a circuit fault, overload and a thermal problem. Before an internal inspection, the installation must be safely disconnected and verified as de-energised.

FAQ

Is a larger distribution board automatically more suitable?

Only if it matches the environment and allows correct fitting. Surplus modules will not replace sufficient depth, terminals or well-thought-out cable routes.

Does the distribution board also contain circuit breakers?

Verify the scope of delivery for the selected type. Mechanical equipment for fixing devices is not the same as the delivery of a fitted and wired distribution board.

A wider selection is offered by the category Control cabinet enclosures; other material variants are represented by Stainless steel and circuit-breaker enclosures.