Phone +420 774 723 123 Cart · 0 · empty

Mechanically Operated Valves

Mechanically operated pneumatic valves – push buttons, selector switches, limit valves with roller or lever and foot pedals. They are operated by hand or by machine movement without an electrical signal. Choose by function (3/2, 5/2), port size and return method.

Filters
Found 5 products
IN STOCK

TE-MOV-03, TECHNOLINE, pneumatic valve with latching push button, G1/8

Cat. no.: TE-MOV-03

TE-MOV-03, TECHNOLINE, pneumatic push button valve with latching; ports G1/8, pressure 0–0.8MPa, 0 to +70°C. Tubes Ø4/6/8mm via suitable fittings.

In stock 5 or more pcs
8,56 €
excl. VAT · 10,36 € incl. VAT
IN STOCK

TE-MOV-02, TECHNOLINE, mechanical pneumatic roller valve, G1/8

Cat. no.: TE-MOV-02

TE-MOV-02, TECHNOLINE, mechanical pneumatic roller valve; ports G1/8, pressure 0–0.8MPa, 0 to +70°C. Tubes Ø4/6/8mm via suitable fittings.

In stock 2 ks
8,56 €
excl. VAT · 10,36 € incl. VAT
IN STOCK

TE-MOV-01, TECHNOLINE, mechanical pneumatic selector switch with rotary knob, G1/8

Cat. no.: TE-MOV-01

TE-MOV-01, TECHNOLINE, mechanical pneumatic valve with rotary knob; ports G1/8, pressure 0–0.8MPa, 0 to +70°C. Tubes Ø4/6/8mm via suitable fittings.

In stock 1 ks
8,58 €
excl. VAT · 10,38 € incl. VAT

Prices include the recycling fee.

Mechanically Operated Valves

A mechanically operated pneumatic valve converts the movement of the actuator into a change in the connection of the air paths. In this category you will find TECHNOLINE TE-MOV selector switches and push buttons, a pneumatic limit switch and the TE-4F210-08LG foot control. Selection starts with the required circuit function, not the colour of the button or the thread size.

Distinguish the actuation method and the valve function

A manually pressed button, a switched lever and a mechanically pressed stop can control different internal passages. The designation 2/2 means two main working ports and two positions; 3/2 three ports and two positions. In the three-way version, the output may be connected to the supply in one position and to the exhaust in the other, but the actual symbol of the specific valve is always decisive.

Another separate property is spring return or retention of the switched position. For the circuit, you need to know what happens when the actuator is released, when air is lost and after the supply is restored. The same number of ports does not answer all these questions. It is advisable to prepare a record of states before ordering.

How to compare specific versions

Product TE-MOV-04 is described in the range as a 3/2 push button with a G1/8. thread TE-4F210-08LG is a foot valve with two positions, four ports and a G1/4. thread. These examples are not substitutes for each other. If the information is ambiguous, request the diagram and identification of the supplied variant.

  • Determine whether the valve controls the working consumer directly or only a pneumatic control signal.
  • Compare flow data under the same measuring conditions; the thread alone does not guarantee the same flow.
  • Verify the permitted medium, pressure, temperature and air quality requirements for the given product.
  • Check the required actuation movement, accessibility and protection against unintended operation.
  • Reserve space for replacing hoses and for the exhaust without kinking them or putting them under mechanical load.

Author's model example: state table

Imagine a fixture in which the operator holds the button for the duration of one working movement. We divide the test record into four states: actuator released, actuator pressed, supply interrupted and supply restored. For each state, we write down in advance the required behaviour of the consumer and the method of verifying it.

If an unexpected movement occurs when pressure is restored, the solution is not to rewrite the expected result to match reality. The circuit and its protective measures must be re-evaluated. This is a methodological test example, not an approved safety circuit or instructions for bypassing guards.

Mounting and troubleshooting

The mechanical stop of the machine must not be replaced by the valve actuating pin without verifying the design. For limit actuation, check the cam position, its approach direction and repeatability. In the event of a slow response, monitor the pressure at the valve and at the consumer and the state of the exhaust path. Carry out tests in a safe mode and depressurise the equipment before disconnecting lines.

For electrically controlled circuits, continue to pneumatic valves. For the supply branch, the relevant ones are air preparation units. A change of the actuation method always requires a new assessment of the entire machine function.

FAQ

Is a red mushroom button automatically an emergency stop?

No. Shape and colour do not prove a safety function. It must result from the documented properties of the components and the verified design of the entire machine.

Can two valves with the same thread be interchanged?

Only after verifying their diagram, return, flow and operating data and mechanical design. The thread confirms only part of the connection compatibility.