NOARK Motor Protection (Motor Starters)

NOARK Ex9SN motor starters for protecting motors against overload and short circuit, with auxiliary contacts. Choose by current setting range.

Filters
Found 6 products
OUR TIP IN STOCK

ASNA11, NOARK, side-mounted auxiliary contact 1NO+1NC for motor starters Ex9SN

Cat. no.: ASNA11

ASNA11, NOARK: side-mounted auxiliary contact for starters Ex9SN, 1NO+1NC, rated switching current 6A and voltage 240V. Separate accessory.

In stock 1 ks
6,56 €
excl. VAT · 7,94 € incl. VAT
OUR TIP IN STOCK

Ex9SN25B1.6A, NOARK, motor starter Ex9SN25B, thermal protection 1–1.6A, 3P, IP20

Cat. no.: Ex9SN25B1.6A

Ex9SN25B1.6A, NOARK Ex9SN25B: adjustable motor protection 1–1.6A, magnetic release 22.5A, 3 poles, IP20. For motors up to 0.37kW at 400VAC (AC-3).

In stock 5 or more pcs
22,20 €
excl. VAT · 26,86 € incl. VAT
OUR TIP IN STOCK

Ex9SN25B6.3A, NOARK, motor starter Ex9SN25B, thermal protection 4–6.3A, 3P, IP20

Cat. no.: Ex9SN25B6.3A

Ex9SN25B6.3A, NOARK Ex9SN25B: adjustable motor protection 4–6.3A, magnetic release 78A, 3 poles, IP20. For motors up to 2.2kW at 400VAC (AC-3).

In stock 1 ks
23,34 €
excl. VAT · 28,24 € incl. VAT
OUR TIP IN STOCK

Ex9SN25B10A, NOARK, motor starter Ex9SN25B, thermal protection 6–10A, 3P, IP20

Cat. no.: Ex9SN25B10A

Ex9SN25B10A, NOARK Ex9SN25B: adjustable motor protection 6–10A, magnetic release 138A, 3 poles, IP20. For motors up to 4kW at 400VAC (AC-3).

In stock 1 ks
27,12 €
excl. VAT · 32,81 € incl. VAT
OUR TIP

Ex9SN25B4A, NOARK, motor starter Ex9SN25B, thermal protection 2.5–4A, 3P, IP20

Cat. no.: Ex9SN25B4A

Ex9SN25B4A, NOARK Ex9SN25B: adjustable motor protection 2.5–4A, magnetic release 51A, 3 poles, IP20. For motors up to 1.5kW at 400VAC (AC-3).

On request
22,20 €
excl. VAT · 26,86 € incl. VAT
OUR TIP

Ex9SN25B2.5A, NOARK, motor starter Ex9SN25B, thermal protection 1.6–2.5A, 3P, IP20

Cat. no.: Ex9SN25B2.5A

Ex9SN25B2.5A, NOARK Ex9SN25B: adjustable motor protection 1.6–2.5A, magnetic release 33.5A, 3 poles, IP20. For motors up to 0.75kW at 400VAC (AC-3).

On request
23,08 €
excl. VAT · 27,93 € incl. VAT

Prices include the recycling fee.

Motor protection (motor starters) NOARK

This category contains NOARK motor starters Ex9SN25B and auxiliary contact ASNA11. When selecting, separate three questions: what current the motor needs, how the feeder is to be protected and what information the machine control should receive. A correctly selected current range does not yet solve all fault conditions or the requirement for remote control.

Ex9SN25B: manual control and protective function

The series uses adjustable overload protection and a fixed instantaneous short-circuit release. The current range and other limit data change between individual versions. The family documentation contains separate tables of settings, breaking capacities and accessories; see technical sheet Ex9SN25B. Therefore do not read the frame size number as a universal setting for all variants.

For automatic operational switching, a downstream contactor is designed in, for example from the category NOARK contactors. Assess the requirement for frequent commands according to the electrical life and permissible switching frequency of the device concerned. A manual protective starter and a contactor have different roles in such an assembly; their functions cannot be interchanged merely because of similar dimensions.

Range according to the motor, not according to the margin in the name

Version Ex9SN25B6.3A, according to the NOARK product data , has a setting range of 4–6.3 A, thermal-magnetic tripping and phase-loss sensitivity. Relate these properties to the specific type. For another motor, assess its current at the intended voltage and connection, the starting profile and the load of the driven equipment.

A higher-current variant is not automatically safer. If its lower limit exceeds the required value, it cannot be justified by a mere “margin”. At the same time, it is not advisable to derive the required range from the measured current of a motor running almost without load; this state may not correspond to the designed duty.

An auxiliary contact is not always a fault signal

The manufacturer describes ASNA11 as a side-mounted auxiliary contact for Ex9SN with one make and one break contact. It is an auxiliary contact, not a separate fault contact; details are in documentation ASNA11. When designing the signalling, therefore specify exactly whether you need the device status or a separate signal that the protection has tripped.

A generic label “motor off” is not enough in the signal list. It can mean an operational command, manual switch-off, protection trip or loss of control supply. Before selecting a contact, define the required meaning of the information and how it will be evaluated. In addition, the add-on block must have space in the control cabinet and the appropriate mechanical assignment.

Breaking capacity and coordination of the whole assembly

Icu describes the rated ultimate short-circuit breaking capacity, Ics the service breaking capacity; they are not two designations of the thermal setting. When comparing data, the voltage and the specific current variant must match. Then verify the protective combination with the contactor separately, including the prospective short-circuit current and any upstream protection.

Interchangeability with another series cannot be determined just by comparing amps. An overview of the context can be found in the category Contactors and motor protection. This page is a guide for specification, not instructions for mains wiring.

Model example for an order

Consider a motor with a rated-plate current of 2.2 A and a requirement for information on the starter position. The current of 2.2 A lies within the 1.6–2.5 A range of version Ex9SN25B2.5A. The variant with the 2.5–4 A range does not cover it. The required auxiliary contact is a separate item of the specification. If the system is to report the cause of tripping instead of the position, the requirement must be re-evaluated; the sum of NO and NC alone does not prove such a function. The example does not verify short-circuit coordination or a specific protection setting.

FAQ

Is phase-loss-sensitive protection the same as a voltage monitoring relay?

No. The sensitivity of motor protection to a fault current condition is not universal monitoring of all mains parameters. Assess any required monitoring of voltage and phase sequence separately.

Do I need to re-verify the protection after replacing the motor?

Yes. The rated current, starting and duty may change even though the new motor fits the machine mechanically. Therefore do not adopt the original configuration without checking.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.