NOARK Residual Current Devices

NOARK Ex9L-N residual current devices and Ex9BL-N combined RCBOs for protecting people and installations. Choose by rated current, rated residual current, type (AC, A) and number of poles.

Filters
Found 9 products
OUR TIP IN STOCK

Ex9L-N 2P 16A 30mA, NOARK, residual current device, 16 A

Cat. no.: Ex9L-N 2P 16A 30mA

Ex9L-N 2P 16A 30mA NOARK – residual current device, 16 A. Key data: 30 mA. Exact technical data for selecting the residual current device / RCBO type.

In stock 5 or more pcs
22,28 €
excl. VAT · 26,96 € incl. VAT
IN STOCK

Ex9L-N 4P 40A 100mA, NOARK, residual current device, 4P, 40A, 100mA, type A

Cat. no.: Ex9L-N 4P 40A 100mA

Ex9L-N 4P 40A 100mA, NOARK: four-pole type A residual current device, 40A, residual sensitivity 100mA, without overcurrent protection.

In stock 1 ks
36,41 €
excl. VAT · 44,05 € incl. VAT
IN STOCK

Ex9L-N 2P 40A 30mA, NOARK, residual current device 2P, 40A, 30mA, type A

Cat. no.: Ex9L-N 2P 40A 30mA

Ex9L-N 2P 40A 30mA, NOARK, residual current device 2P, 40A, 30mA, type A. The two-pole residual current device of the Ex9L-N series is designed to monitor residual current in a single-phase…

In stock 1 ks
45,77 €
excl. VAT · 55,39 € incl. VAT

Ex9L-N 2P 25A 30mA, NOARK, residual current device type A, 2P, 25A, 30mA, 230VAC

Cat. no.: Ex9L-N 2P 25A 30mA

NOARK Ex9L-N 2P 25A A 30mA, order no. 108349: type A residual current device, 2-pole, 25A, residual current 30mA, 230VAC, DIN mounting.

On request
21,70 €
excl. VAT · 26,26 € incl. VAT

Ex9L-N 4P 16A 30mA, NOARK, residual current device, 16 A

Cat. no.: Ex9L-N 4P 16A 30mA

Ex9L-N 4P 16A 30mA NOARK – residual current device, 16 A. Key data: 30 mA. Exact technical data for selecting the residual current device / RCBO type.

On request
24,41 €
excl. VAT · 29,54 € incl. VAT

Ex9L-N 4P 25A 30mA, NOARK, residual current device, 4P, 25A, 30mA, type A

Cat. no.: Ex9L-N 4P 25A 30mA

Ex9L-N 4P 25A 30mA, NOARK: four-pole type A residual current device, 25A, residual sensitivity 30mA, without overcurrent protection.

On request
25,03 €
excl. VAT · 30,28 € incl. VAT

Ex9L-N 4P 40A 30mA, NOARK, residual current device type A, 4P, 40A, 30mA, 400VAC

Cat. no.: Ex9L-N 4P 40A 30mA

NOARK Ex9L-N 4P 40A A 30mA, order no. 108362: four-pole type A residual current device, 40A, 30mA, 400VAC, for DIN distribution boards.

On request
25,89 €
excl. VAT · 31,32 € incl. VAT
OUR TIP

Ex9BL-N 1P+N B10 30mA, NOARK, combined residual current device with circuit breaker 1P+N, B10, 10A, 30mA, type A

Cat. no.: Ex9BL-N 1P+N B10 30mA

Ex9BL-N 1P+N B10 30mA, NOARK, combined residual current device with circuit breaker 1P+N, B10, 10A, 30mA, type A. The combined device NOARK Ex9BL-N combines overcurrent protection and residual…

On request
32,72 €
excl. VAT · 39,59 € incl. VAT

Prices include the recycling fee.

NOARK residual current devices

The range combines separate residual current devices Ex9L-N and combined devices Ex9BL-N. Two-pole and four-pole RCCBs as well as combinations 1P+N are represented; the range includes 30 mA and 100 mA versions. Decide first according to the required protective function, then according to current, sensitivity and version. A similar front toggle does not mean the same protection or automatic interchangeability during repair.

Principle and difference between RCCB and RCBO

Residual current protection evaluates the imbalance between the currents entering the protected circuit and returning. Leakage can exist even with a small working load; the principle is explained by NOARK in its overview of residual current protection. A low load by itself therefore does not prove a fault-free state of the insulation.

Ex9L-N is an RCCB without built-in overcurrent protection. Ex9BL-N is an RCBO, which adds overload and short-circuit protection. The conditional short-circuit current of an RCCB is not the same as the breaking capacity of the circuit breaker part of an RCBO; for an RCCB, the prescribed protective combination must be verified.

In, IΔn and sensitivity to the current waveform

In denotes the rated current, IΔn the rated residual operating current. The amps of the first value and the milliamps of the second cannot be interchanged.

Changing In does not solve the required residual sensitivity. For an RCBO, also distinguish the tripping characteristic of the built-in circuit breaker from the type of RCD; the letter B in designation B16 does not by itself mean a type B RCD.

Type AC responds to alternating residual current, type A also to pulsating direct current. Type A cannot be presented as protection against all DC fault currents.

A shortened or incomplete designation is not enough to determine the type offered precisely; you need agreement of the full code, description and rating plate. The properties of another version of the same series are not automatically transferred. The same IΔn value does not guarantee the same response to a different current waveform.

When selecting, request the documentation of the supplied equipment, especially if it contains power electronics. In the brief, state the required residual current waveform, the timing behaviour of the protection and the number of poles. The presence of the same manufacturer's logo on two devices does not by itself confirm their coordination or selectivity.

Mounting, testing and servicing

Preparation for mounting includes space, covers and accessibility of the test button. Entrust the specific installation and measurements to a qualified person. At handover, have the prescribed operational testing and the method of recording results explained. The documentation must make it possible to unambiguously assign the device to the protected circuit even after a future change in the control cabinet fitting.

In the event of a nuisance trip, note the time, the operating state and any relationship with humidity, cleaning or switching on a load. For a combined device, distinguish possible overcurrent and residual causes. Diagnostics should be based on measurement and documentation; the toggle position alone does not determine the type of fault. Do not bypass the protection and do not consider raising the sensitivity threshold to be an automatic elimination of the cause.

Author's model calculation: current balance

For our own teaching model of a single-phase circuit, consider a current of 2.000 A towards the load and 1.982 A returning via the monitored path. The difference is 2.000 − 1.982 = 0.018 A = 18 mA. We assume the same waveform and timing of both currents. The calculation illustrates the imbalance; it does not determine the actual operating current, tripping time or safety of a specific installation. With general waveforms, it is not enough to subtract any two readings of an ordinary ammeter.

FAQ

Does a standalone RCCB also protect against overload?

No. Overcurrent protection must be provided separately and its coordination verified for the specific assembly. A higher In value alone does not add this function.

Does the TEST button prove that the whole installation is fault-free?

No. An operational test of the device is not a complete check of the protective conditions. The result does not replace the professional measurement required when verifying a specific circuit.