CYA-0,5 ZE, TECHNOLINE, CYA wire 0.5 mm², package - 200m, green, H05V-K, 200 m
CYA-0,5 ZE TECHNOLINE – CYA wire 0.5 mm², package - 200m, green, H05V-K, 200 m. Exact technical data for selecting the type single-core CYA wire.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Flexible single-core wires H07V-K (CYA) for fixed wiring in control cabinets and machines. Choose by cross-section, colour and length; terminate the ends with wire ferrules.
CYA-0,5 ZE TECHNOLINE – CYA wire 0.5 mm², package - 200m, green, H05V-K, 200 m. Exact technical data for selecting the type single-core CYA wire.
CYA-0,5 TM TECHNOLINE – CYA wire 0.5 mm², package - 200m, dark blue, H05V-K, 200 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-0,5 CE TECHNOLINE – single-core wire, 0.5 mm², black, 200 m. Exact technical data for selecting the type single-core CYA wire.
CYA-0,5 SM TECHNOLINE – CYA wire 0.5 mm², package - 200m, light blue, H05V-K, 200 m. Exact technical data for selecting the type single-core CYA wire.
CYA-0,5 RU TECHNOLINE – CYA wire 0.5 mm², package - 200m, red, H05V-K, 200 m. Exact technical data for selecting the type single-core CYA wire.
CYA-0,5 ZZ TECHNOLINE – CYA wire 0.5 mm², package -200m, green-yellow, , H05V-K, 200 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-0,75 TM TECHNOLINE – CYA wire 0.75 mm², package - 100m, dark blue, , H05V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K), 0.75mm. Exact technical data for selecting the…
CYA-1,0 CE TECHNOLINE – wire, package - 100m, 1.0 mm², black, 100 m. Exact technical data for selecting the type single-core CYA wire.
CYA-1,0 SM TECHNOLINE – CYA wire 1.0 mm², package - 100m, light blue, H05V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-1,0 RU TECHNOLINE – CYA wire 1.0 mm², package - 100m, red, H05V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type single-core…
CYA-1,0 TM TECHNOLINE – CYA wire 1.0 mm², package - 100m, dark blue, H05V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-1,0 ZZ TECHNOLINE – CYA wire 1.0 mm², package - 100m, green-yellow, H05V-K, 100 m. Exact technical data for selecting the type single-core CYA wire.
CYA-1,5 CE TECHNOLINE – CYA wire 1.5 mm², package - 100m, black, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-1,5 SM TECHNOLINE – CYA wire 1.5 mm², package - 100m, light blue, H07V-K, 100 m. Exact technical data for selecting the type single-core CYA wire.
CYA-1,5 RU TECHNOLINE – wire, package - 100m, 1.5 mm², red, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type single-core CYA wire.
CYA-1,5 TM TECHNOLINE – CYA wire 1.5 mm², package - 100m, dark blue, , H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-1,5 ZZ TECHNOLINE – CYA wire 1.5 mm², package - 100m, green-yellow, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-2,5 CE TECHNOLINE – CYA wire 2.5 mm², package - 100m, black, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-2,5 ZZ TECHNOLINE – CYA wire 2.5 mm², package - 100m, green-yellow, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-2,5 SM TECHNOLINE – CYA wire 2.5 mm², package - 100m, light blue, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-2,5 RU TECHNOLINE – CYA wire 2.5 mm², package - 100m, red, , H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type…
CYA-4 CE TECHNOLINE – CYA wire 4 mm², package - 100m, black, H07V-K, 100 m. Key data: -15°C to 70°C, 350/500 V (H05V-K), 450/750 V (H07V-K). Exact technical data for selecting the type single-core…
Prices include the recycling fee.
The stranded single-core construction makes it easier to route and terminate individual electrical connections. However, choose the cross-section together with the installation method, protection, route length and permitted voltage drop. The same wire can have a different current-carrying capacity under different conditions. A decision based on a single “cross-section versus amperes” table is therefore not a complete circuit design.
The category includes cross-sections 0.5; 0.75; 1; 1.5; 2.5 and 4 mm². Smaller cross-sections are H05V-K, larger ones H07V-K. The items come in various colours; the 0.5 mm² packaging is stated per 200 m, the other packages found per 100 m.
Before ordering, make a list of lengths for each colour and cross-section. Add the actual service loops and terminations, not an automatic reserve used without knowing the route. The nominal cross-section in mm² does not mean the outer diameter in millimetres. That is important, for example, when passing through a cable gland or assessing duct fill.
The Schneider Electric methodology distinguishes installation methods and corrections for ambient temperature or grouping of circuits. The permitted current is determined for specific conditions, material and insulation; it cannot be assigned to the cross-section alone without these data.
When designing a control cabinet, describe the least favourable section of the route. A short passage through a warm spot or a tight bundle can decide the choice of the entire wiring. Find out how many cores will be loaded at the same time and which loads may operate together. Separately check the maximum temperature permitted by the connected terminal or device.
Choose protection together with the wiring; see the related category Circuit breakers and RCDs. A higher rated current of the circuit breaker cannot compensate for unsuitable installation of the wires. When the load changes, therefore recalculate the circuit as a whole, including the supply and connection points.
Voltage drop calculation works with the current and impedance of the line; for a simple DC circuit, use the resistance of the entire current loop.
Own model: a 24 V DC load draws 3 A and is located 20 m from the power supply. Two copper cores form a total of 40 m of wiring. For a simplified calculation at approximately 20 °C, let us choose a resistivity of 0,0175 Ω·mm²/m. With a cross-section of 1.5 mm², the loop resistance is R = 0,0175 × 40 / 1.5 ≈ 0.467 Ω and the drop ΔU = 3 × 0.467 ≈ 1.40 V, i.e. about 5.8 % of 24 V.
Under the same model conditions and 2.5 mm², the drop falls to 0.84 V, i.e. 3.5 %. The result does not prove the permissible current load or the correctness of the protection. The model neglects contact resistances and heating; use the actual resistance according to the wire documentation and operating temperature. Compare the acceptability of the drop with the requirement of the connected equipment, including its start-up.
According to verification of thermal withstand during a short circuit within the validity range of the adiabatic model, at most up to five seconds, the let-through I²t is compared with k²S². The factor k depends on the material, insulation and temperature limits. In addition to thermal withstand, also check sufficiently fast disconnection at the lowest expected fault current.
In practice, you need data on the protective device and fault conditions at the installation site. The normal load current alone is not enough. A long line may have an acceptable operating current, but during a fault it may limit the current so much that the selected protection does not respond as required.
In the category Terminals, terminal blocks compare the permitted cross-section and conductor design for the specific terminal. The need for a ferrule is determined by the connection system; its size, length and crimping must match the conductor. Do not insert several cores into one ferrule or terminal unless the given solution is explicitly suitable.
During installation, do not damage individual strands when stripping, and make sure the insulation does not enter the contact area. Protect the wiring against sharp edges and tension. The necessary grommets, ferrules and cable routing are covered by Electrical consumables.
No. For the CYA-0,5 CE assessed here, fixed installation is stated. For repeated bending, for example in a moving supply cable, choose a wire explicitly intended for that purpose.
First check the contact, stripping, crimping and tightening according to the terminal manufacturer. A faulty connection can remain a thermal problem even with a larger core.
The colour coding must correspond to the function of the circuit and the rules for the electrical equipment used. A change must preserve clear identification during installation and service.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.