Phone +420 774 723 123 Cart · 0 · empty

Siemens Contactors

Siemens SIRIUS 3RT contactors and 3RH contactor relays for switching motors and control circuits. Choose by AC-3 current, coil voltage (AC/DC) and auxiliary contacts.

Filters
Found 38 products
IN STOCK

3RT2916-1DG00, Siemens, SIRIUS suppressor diode 12–250VDC, contactor coil protection 3RT2.1/3RH2

Cat. no.: 3RT2916-1DG00

3RT2916-1DG00, Siemens: is a protective suppressor module with a diode designed to limit voltage peaks of the control coil. The manufacturer states an operating range of 12–250VDC and use with series…

In stock 5 or more pcs
5,32 €
excl. VAT · 6,44 € incl. VAT
−50 % IN STOCK

3RH1122-1AD00, Siemens, SIRIUS auxiliary contactor S00, 2NO+2NC, coil 42VAC/50–60Hz, screw terminals

Cat. no.: 3RH1122-1AD00

3RH1122-1AD00, Siemens: is a SIRIUS 3RH1 generation auxiliary contactor with a 2NO+2NC. configuration. The manufacturer datasheet for this exact model states a control coil 42VAC for frequency…

In stock 2 ks
8,19 € 16,37 €
excl. VAT · 9,91 € incl. VAT
−50 % IN STOCK

3RH1140-1AD00, Siemens, SIRIUS auxiliary contactor S00, 4NO, coil 42VAC/50–60Hz, screw terminals

Cat. no.: 3RH1140-1AD00

3RH1140-1AD00, Siemens: is a SIRIUS 3RH1 generation auxiliary contactor with a 4NO. configuration. The manufacturer datasheet for this exact model states a control coil 42VAC for frequency 50/60Hz…

In stock 1 ks
8,19 € 16,37 €
excl. VAT · 9,91 € incl. VAT
IN STOCK

3RH1131-1AD00, Siemens, SIRIUS auxiliary contactor S00, 3NO+1NC, coil 42VAC/50–60Hz, screw terminals

Cat. no.: 3RH1131-1AD00

3RH1131-1AD00, Siemens: is a SIRIUS 3RH1 generation auxiliary contactor with a 3NO+1NC. configuration. The manufacturer datasheet for this exact model states a control coil 42VAC for frequency…

In stock 1 ks
16,37 €
excl. VAT · 19,81 € incl. VAT
IN STOCK

3RT2016-1BB42, Siemens, SIRIUS power contactor, 3NO, AC-3 9A/400VAC, 4kW, coil 24VDC, 1NC

Cat. no.: 3RT2016-1BB42

3RT2016-1BB42, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 9A and the catalogue motor power is 4kW at 400VAC. Integrated…

In stock 5 or more pcs
21,50 €
excl. VAT · 26,02 € incl. VAT
IN STOCK

3RT2017-1BB42, Siemens, SIRIUS power contactor, 3NO, AC-3 12A/400VAC, 5.5kW, coil 24VDC, 1NC

Cat. no.: 3RT2017-1BB42

3RT2017-1BB42, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 12A and the catalogue motor power is 5.5kW at 400VAC. Integrated…

In stock 5 or more pcs
26,09 €
excl. VAT · 31,57 € incl. VAT
−5 % IN STOCK

3RN2000-2AA30, Siemens, SIRIUS thermistor motor protection relay 3RN2, 24V AC/DC, changeover contact, spring-type terminals

Cat. no.: 3RN2000-2AA30

3RN2000-2AA30, Siemens: The thermistor protection relay evaluates the thermal protection of the motor. It has a 24V AC/DC supply, one changeover output, automatic RESET and spring-type terminals. The…

In stock 5 or more pcs
29,91 € 31,48 €
excl. VAT · 36,19 € incl. VAT
IN STOCK

3RT2017-1BB41, Siemens, SIRIUS power contactor S00, 3NO, 12A AC-3/400VAC, 5.5kW, coil 24VDC, 1NO

Cat. no.: 3RT2017-1BB41

3RT2017-1BB41, Siemens: The power contactor switches a three-phase motor load using three main make contacts. At 400VAC it has a rated current of 12A in category AC-3 and a power of 5.5kW. It is…

In stock 5 or more pcs
31,53 €
excl. VAT · 38,15 € incl. VAT
IN STOCK

3RT1916-2DG21, Siemens, SIRIUS electronic timing module, OFF-delay 0.5–10s, 24–66V AC/DC, S00

Cat. no.: 3RT1916-2DG21

3RT1916-2DG21, Siemens: The Siemens SIRIUS 3RT1916-2DG21 electronic timing module provides an OFF-delay with an adjustable interval of 0.5–10s. It is intended for mounting on size S00 contactors; the…

In stock 1 ks
32,75 €
excl. VAT · 39,62 € incl. VAT
−3 % IN STOCK

3RT2025-1BB40, Siemens, SIRIUS power contactor, 3NO, AC-3 17A/400VAC, 7.5kW, coil 24VDC, 1NO+1NC

Cat. no.: 3RT2025-1BB40

3RT2025-1BB40, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 17A and the catalogue motor power is 7.5kW at 400VAC. Integrated…

In stock 5 or more pcs
54,78 € 56,47 €
excl. VAT · 66,28 € incl. VAT

3RH1911-1GA22, Siemens, SIRIUS auxiliary contact block 2NO+2NC for contactors 3RH1, front-mounted, screw terminals

Cat. no.: 3RH1911-1GA22

3RH1911-1GA22, Siemens: is a front-mounted auxiliary contact block with two make and two break contacts. The designation 62E, snap-on fixing and screw terminals are stated directly in the Siemens…

On request
6,92 €
excl. VAT · 8,37 € incl. VAT

3RT2916-1LM00, Siemens, SIRIUS suppressor diode with LED for coils 24–70VDC, contactors 3RT2.1/3RH2

Cat. no.: 3RT2916-1LM00

3RT2916-1LM00, Siemens: is a suppression accessory consisting of a protective diode and a signalling LED. The manufacturer specifies it for 24–70VDC coils of contactors 3RT2.1 and auxiliary…

On request
7,16 €
excl. VAT · 8,67 € incl. VAT

3RM1920-1AA, Siemens, infeed terminal for SIRIUS three-phase busbars 3RM1

Cat. no.: 3RM1920-1AA

3RM1920-1AA, Siemens: is an infeed terminal for the three-phase supply system of motor starters 3RM1 with screw connection.

On request
12,89 €
excl. VAT · 15,60 € incl. VAT

3RM1910-1BA, Siemens, three-phase busbar for 3 SIRIUS 3RM1 starters

Cat. no.: 3RM1910-1BA

3RM1910-1BA, Siemens: is a three-phase busbar for the common supply of 3 SIRIUS 3RM1. motor starters. It is an accessory of the supply system, not a standalone starter.

On request
14,86 €
excl. VAT · 17,98 € incl. VAT

3RM1910-1DA, Siemens, three-phase busbar for 5 SIRIUS 3RM1 starters

Cat. no.: 3RM1910-1DA

3RM1910-1DA, Siemens: is a three-phase busbar for the common supply of 5 SIRIUS 3RM1. motor starters. It is an accessory of the supply system, not a standalone starter.

On request
19,57 €
excl. VAT · 23,68 € incl. VAT

3RT2023-1AL20, Siemens, SIRIUS power contactor S0, 3NO, AC-3 9A/400VAC, 4kW, coil 230VAC, 1NO+1NC

Cat. no.: 3RT2023-1AL20

3RT2023-1AL20, Siemens: is a three-pole SIRIUS power contactor for motor loads. In category AC-3 at 400VAC the rated current is 9A and the power 4kW. It is controlled by a 230VAC/50–60Hz coil; the…

On request
21,92 €
excl. VAT · 26,52 € incl. VAT

Prices include the recycling fee.

Siemens contactors

The Siemens range includes power contactors, auxiliary contactors and separate accessories. Therefore do not select the 3RT and 3RH series as interchangeable devices with the same number of contacts. For replacement, the complete order code, size, control voltage and function of the individual circuits are important; the SIRIUS designation or the appearance of the front alone is not enough.

Power 3RT and auxiliary 3RH

For the 3RT2016-1BB42 on offer, the manufacturer states 9 A in AC-3e/AC-3, a motor power of 4 kW at 400 V, three main poles, 24 V DC control and one auxiliary NC. The parameters relate to this order number; see the Siemens 3RT2016-1BB42 data sheet. A different suffix may change the control or the version.

Auxiliary contactor 3RH2131-1AB00 has a 3 NO + 1 NC combination and a 24 V AC coil. It is intended for control functions; the current ratings of its contacts are assessed in the relevant auxiliary circuit categories, not as the power AC-3 rating of a three-pole motor contactor. The source is the auxiliary contactor data sheet 3RH2131-1AB00.

What current, power and voltage actually mean

The current for AC-1 and the motor current for AC-3 are not interchangeable values. The power in kW is linked to the specified voltage and type of motor duty. If you keep only the power when replacing, you may overlook a different control voltage, number of auxiliary contacts or a more demanding switching duty.

Also assess starting, switching off during running and the frequency of short commands. Demanding jogging is not the same as occasionally switching on a fan. Formulate the requirement according to the actual machine cycle; the mechanical number of operations alone does not prove electrical life under a specific load.

Coil, suppression and compatible accessories

The designations 24 V AC and 24 V DC cannot be interchanged just because the numerical value matches. The control output must suit the coil type and its consumption in the individual states. Before adding suppression, check whether the version already includes it, which element the manufacturer permits and how it affects the contactor drop-out.

For example, 3RT2916-1DG00 is a diode suppressor for 12–250 V DC, intended for the listed series 3RT2.1 and 3RH2. It is not a universal module for every Siemens coil; the assignment is given in the suppressor diode data sheet. Similarly, select add-on contact blocks according to the exact design series and the prescribed location.

Different generations of accessories appear in the range. The same size or similar first characters of the code do not confirm mechanical interchangeability. A separate category is dedicated to another platform Contactors and auxiliary contacts; its parts cannot be transferred to Siemens without documented assignment.

Mounting and protective assembly

Check the space after adding accessories, access to the terminals and the thermal situation in the control cabinet. Assess the installation conditions according to the exact variant and its documentation. The mounting dimension of the basic body may not correspond to the envelope of the whole fitted combination.

A contactor does not replace overload and short-circuit protection. The specific feeder must have designed protective devices and verified coordination; neither the brand nor the AC-3 category constitutes such verification. The division of functions is explained in the parent category Contactors and motor protection.

Model example of checking a spare part

Consider a machine with 24 V DC control, a three-phase 400 V motor and a rated-plate current of 8 A, which is switched off after starting during normal running. In terms of these selected data, 3RT2016-1BB42 with a rating of 9 A in AC-3. can be assessed preliminarily. By contrast, 3RH2131-1AB00 is not a suitable replacement: it is an auxiliary device with a different contact function and an AC coil. The example does not verify protective coordination or the permissible operating load of the complete equipment.

FAQ

Does an auxiliary contact prove that the motor is actually disconnected?

Not automatically. For the required feedback, the properties of the specific contact and the evaluation design must be verified. The NO or NC designation alone does not guarantee a safety function.

Can I add any suppressor?

No. The type of supply, voltage range, design assignment and required timing behaviour are decisive. Verified accessories are part of the correct specification, not an optional substitute for professional design.

Cookies on this website