Pneumatic Boosters

SMC VBA series pneumatic boosters increase air pressure up to double without electrical energy. They help where the supply is not sufficient for the required cylinder force. Choose by required pressure, flow and tank size.

Filters
Found 2 products
OUR TIP

VBA11A-F02, SMC, air pressure booster up to 4×, thread G1/4

Cat. no.: VBA11A-F02

VBA11A-F02, SMC – pneumatic pressure booster; Pressure increase ratio: up to 4×; Connection thread: G1/4; Principle: pneumatic, without electrical power supply.

On request
370,77 €
excl. VAT · 448,64 € incl. VAT
OUR TIP

VBA40A-F04GN, SMC, pressure booster 2×, G1/2, 2 pressure gauges, silencer

Cat. no.: VBA40A-F04GN

VBA40A-F04GN, SMC – pneumatic pressure booster; Pressure increase ratio: 2×; Connection: G1/2; GN accessories: 2 pressure gauges and silencer.

On request
1 158,49 €
excl. VAT · 1 401,78 € incl. VAT

Prices include the recycling fee.

Pneumatic Boosters

A pneumatic booster increases the compressed air pressure for a selected branch of the machine. It is worth considering where a local task needs a higher pressure than the other consumers. Before selecting, however, separate the required pressure, the instantaneous flow and the frequency of working cycles. A higher reading on the pressure gauge without consumption does not by itself prove that the device can handle the production cycle.

What to check with the SMC VBA series

This category includes VBA11A-F02 and VBA40A-F04GN. According to the SMC VBA catalogue VBA11A works with a pressure increase ratio of 2 to 4, while VBA40A works with a ratio of 2. For VBA11A, the inlet pressure range is 0.1–1 MPa and the outlet setting 0.2–2 MPa; these values are not interchangeable. The manufacturer specifies flow characteristics according to which the achievable outlet pressure drops as consumption increases. The standard version requires horizontal installation. When designing, follow the documentation of the exact order code.

The booster does not create energy for free: part of the supplied air is used for its drive. Therefore, make the operating comparison for the whole station and its actual working mode. Record the production time, idle time and the number of consumers working simultaneously. An occasional short stroke is a different requirement from a continuous consumption of the same peak flow.

Procedure for specifying the working task

  • Measure the pressure upstream of the booster also when other branches are loaded, not only at rest.
  • Determine the lowest acceptable pressure directly at the working element and include the loss in the supply line.
  • Describe the consumption over time: volume per cycle, duration of consumption and time to the next cycle.
  • Compare this operating point with the characteristic of the selected version, not just with the maximum in the heading.
  • Determine the limit pressure of all downstream components and a suitable overpressure protection solution.

Author's model example: the significance of the working cycle

Consider a consumer that, in the model, consumes 3 normal litres of air per cycle. Ten cycles per minute means an average consumption of 30 Nl/min. However, if the actual consumption lasts only half a second, it corresponds to a flow of 360 Nl/min during this part of the cycle. Both values are correct, but describe a different time level.

A tank can bridge a short peak, but it must have time to refill. Its volume cannot be determined from the difference of these flows alone: the calculation includes the permitted pressure drop, the actual inflow and the time sequence of consumption. The example is not a sizing of a specific VBA or a recommendation for a specific pressure vessel. It shows which data the process engineer should provide to the designer.

Commissioning and diagnostics

Prepare the measurement of the inlet and outlet pressure in the same time record. If the inlet drops at the same time, first look for a restriction upstream of the booster. If the inlet is stable and the outlet drops only during repeated working cycles, compare the load profile with the design. Supplement the result with the regulator setting, line lengths and the state of the air preparation.

Before opening the system, safely disconnect the supply and verify that all separated volumes are depressurised. Air may remain trapped behind a fitting or in the tank. For the downstream distribution, use air preparation and suitable pneumatic hoses, always within the limits of their specific version.

FAQ

Is it enough to know the boost ratio when selecting?

No. You also need the operating point under consumption and the consumption profile over time. Reaching the pressure with no load is not a test of performance in production.

Will a larger tank solve a permanently insufficient air supply?

No. It increases the available short-term reserve, but if consumption is higher than replenishment over a long period, the pressure will gradually drop.