Phone +420 774 723 123 Cart · 0 · empty

Push Buttons, 30 mm Mounting

EMAS H200 series emergency stop buttons for 30 mm holes. Choose by head diameter, release method, number of contacts and space behind the panel.

Filters
Found 2 products
OUR TIP IN STOCK

H200E, EMAS, emergency stop button, 1 NC, turn-to-release, 30 mm

Cat. no.: H200E

H200E EMAS – emergency stop button, 1 NC, 30 mm. Technical parameters, application and variant selection.

In stock 5 or more pcs
4,46 €
excl. VAT · 5,40 € incl. VAT
OUR TIP IN STOCK

H200EE, EMAS, emergency stop button, 30 mm

Cat. no.: H200EE

H200EE EMAS – emergency stop button, 30 mm. Technical parameters, application and variant selection.

In stock 5 or more pcs
4,46 €
excl. VAT · 5,40 € incl. VAT

Prices include the recycling fee.

Emergency stop buttons for 30 mm mounting

Mounting hole and actuator contour

This branch separates components for the 30 mm mounting dimension from the common 22 mm group. It is not a general rule that a larger head means a larger mounting hole. Compare the drawing of the selected version, the panel thickness and the anti-rotation method. Subsequently modifying the hole during replacement constitutes a change of the mounting solution; first check whether it is permissible and the surrounding space.

Selection data – Push Buttons, 30 mm Mounting

Step What to document
Identification hole drawing and assembly H200
Operating requirements contacts and release of the specific variant
Acceptance seating and functional behaviour of the equipment

What you will find in the range

The public listing includes EMAS H200E and H200EE. Sheet H200E states a normally closed contact and turn-to-release; do not automatically transfer these data to the other variant. Confirm the complete code, composition of the delivery and the contact block diagram. For a service replacement, also record the type of the original holder, terminal markings and wire positions.

Electrical and mechanical match

The replacement must satisfy both interfaces at the same time. A mechanical match allows installation, an electrical match ensures the prescribed signal function. Distinguish between NC and NO contacts and the required opening properties according to the documentation of the specific assembly. A change in the number of contacts may affect diagnostics and auxiliary signalling; it is not solved simply by replacing the head.

Acceptance after replacement

Before connection, secure the equipment according to its service procedure. After mounting, check secure seating, free movement, latching and the release method. The functional test must include the equipment's response on pressing and the restart procedure. Releasing the button is not in itself a command to start. Record the result together with the types of parts used.

How to prepare an enquiry

Add the hole size, the available depth behind the panel, the contact diagram and the complete designation to the photo of the front. If any information is uncertain, mark it explicitly. The supplier can then assess a suitable assembly without guessing from a photo. The design and verification of the safety function are dealt with by the machine documentation and a competent expert.

FAQ

Can I insert a common 22 mm assembly into a 30 mm hole?

Only with a confirmed mounting solution intended for the given assembly. Free play or an improvised washer is not a verified replacement.

Is H200EE automatically the same version as H200E?

Compare the documentation of the complete codes; a suffix can change the properties and the scope of delivery.