This branch separates components for the 30 mm mounting dimension from the common 22 mm group. It is not a general rule that a larger head means a larger mounting hole. Compare the drawing of the selected version, the panel thickness and the anti-rotation method. Subsequently modifying the hole during replacement constitutes a change of the mounting solution; first check whether it is permissible and the surrounding space.
| Step | What to document |
|---|---|
| Identification | hole drawing and assembly H200 |
| Operating requirements | contacts and release of the specific variant |
| Acceptance | seating and functional behaviour of the equipment |
The public listing includes EMAS H200E and H200EE. Sheet H200E states a normally closed contact and turn-to-release; do not automatically transfer these data to the other variant. Confirm the complete code, composition of the delivery and the contact block diagram. For a service replacement, also record the type of the original holder, terminal markings and wire positions.
The replacement must satisfy both interfaces at the same time. A mechanical match allows installation, an electrical match ensures the prescribed signal function. Distinguish between NC and NO contacts and the required opening properties according to the documentation of the specific assembly. A change in the number of contacts may affect diagnostics and auxiliary signalling; it is not solved simply by replacing the head.
Before connection, secure the equipment according to its service procedure. After mounting, check secure seating, free movement, latching and the release method. The functional test must include the equipment's response on pressing and the restart procedure. Releasing the button is not in itself a command to start. Record the result together with the types of parts used.
Add the hole size, the available depth behind the panel, the contact diagram and the complete designation to the photo of the front. If any information is uncertain, mark it explicitly. The supplier can then assess a suitable assembly without guessing from a photo. The design and verification of the safety function are dealt with by the machine documentation and a competent expert.
Only with a confirmed mounting solution intended for the given assembly. Free play or an improvised washer is not a verified replacement.
Compare the documentation of the complete codes; a suffix can change the properties and the scope of delivery.
Related selection: Push Buttons, 22 mm Mounting · Box + Push Button · Accessories.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.