EPRFR2K, EMAS, socket; supply: 230 V AC; for DIN rail; colour: red
EPRFR2K EMAS – socket; supply: 230 V AC; for DIN rail; colour: red. Exact technical data for selecting the industrial socket / plug type.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS DIN rail sockets and industrial sockets and plugs 230 V and 400 V. Choose by number of poles, current, voltage and mounting.
EPRFR2K EMAS – socket; supply: 230 V AC; for DIN rail; colour: red. Exact technical data for selecting the industrial socket / plug type.
PC-104-0B, PC Electric, panel-mounted socket 16A for 230VAC. Version and basic data confirmed by TECHNOLINE according to the product export.
ECE416V5PU, EMAS, 4-pole (3P+PE) CEE cable socket with a current of 16A, voltage class 380–415VAC, screw terminals and protection rating IP44.
ECE416V5FU, EMAS, 4-pole (3P+PE) CEE cable plug with pin contacts, 16A, 380–415VAC, with screw terminals and IP44.
ECE532V6PU, EMAS, 5-pole (3P+N+PE) CEE cable socket, 32A, rated range 200/346–240/415VAC, screw terminals and IP44.
ECE532V6FU, EMAS, 5-pole (3P+N+PE) CEE cable plug with pin contacts, 32A, rated range 200/346–240/415VAC, IP44.
Prices include the recycling fee.
A panel socket and an industrial cable connector are different connection methods. When selecting, not only the 230 or 400 V rating matters, but also the current, number and function of the contacts, the design and the matching counterpart. The design of mains equipment connections belongs to a qualified person; the following overview is for selecting material, not instructions for wiring conductors.
The range includes, for example, the red EMAS socket EPRFR2K for DIN rail and industrial cable versions EMAS ECE. For EPRFR2K the manufacturer states the arrangement 2P+E; see the overview of EMAS EPR sockets. Rail mounting does not mean that the socket is an universal power point for any appliance.
For its location, choose the corresponding DIN rail and related mounting material. A cable connector, on the other hand, requires assessment of the cable entry, strain relief and handling space. An appliance version is in turn selected according to the fixing interface as well. These designs cannot be interchanged just on the basis of the same voltage.
The listing also includes Festo KMEB-1-24-2.5-LED, number 151688. Its Festo manufacturer data sheet specifies a connector for a solenoid valve, type C version and a rated voltage of 24 V DC. It is not an ordinary 230/400 V mains socket. For selecting this part, the exact coil type, connection interface and voltage of the specific variant are decisive; mere joint listing in the catalogue does not prove electrical interchangeability.
For an industrial connection, distinguish between the requirement for working conductors and the protective contact. The designations 3P+PE and 3P+N+PE describe different arrangements; the neutral conductor and the protective conductor do not have the same function. Their need is determined by the equipment and the designed system, not just by the rated power of the appliance.
Mechanical coding helps distinguish connector systems. The meaning of the protective contact position and colour coding is explained in the MENNEKES technical overview. The figure in hours is not a current designation and colour alone is not enough to confirm compatibility. Compare the complete marking of both mating parts.
The rated current of a connector is not automatically the permissible consumption of an arbitrarily assembled supply. The design must include the cable, circuit protection, installation conditions and the character of the appliance. A higher figure on a new connector does not by itself justify increasing the load on the existing wiring. An ordinary connector also cannot be considered a device intended for operational switching under load without documentation.
The protection rating is verified for a specific state and version, for example for a mated pair or a closed socket. The assessment includes the cable entry and sealing. The general properties of one series must not be extended to all similarly coloured versions. Related installation material can be found in the root category of electrical consumables.
Our own brief assumes equipment requiring three phases, a working neutral conductor and a protective conductor. Its connection requirement therefore cannot be met by a four-contact arrangement 3P+PE, even if the voltage and current matched. The required number and function of contacts must be maintained throughout the verified connection system.
The example does not select a specific adapter or give instructions for modifying conductors. It shows why an order should not be shortened to “400 V socket”. The brief should also include the contact arrangement, coding and mounting version.
No. Colour is only part of the identification. Verify the current, voltage, frequency, contact arrangement and mechanical coding.
No. Space requirements are addressed together with the electrical design, not as a substitute for the required parameters.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.