305801/XX3, SUPU, marking labels for terminal blocks, numbers 21–30
305801/XX3 (SUPU): marking labels for terminal blocks, numbers 21–30. For building the terminal strip and identifying the correct accessories.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
SUPU 2.5 mm² screw terminal blocks in single and double-level versions. Choose by cross-section and accessories.
305801/XX3 (SUPU): marking labels for terminal blocks, numbers 21–30. For building the terminal strip and identifying the correct accessories.
305801/XX2 (SUPU): marking labels for terminal blocks, numbers 11–20. For building the terminal strip and identifying the correct accessories.
305801/XX4 (SUPU): marking labels for terminal blocks, numbers 31–40. For building the terminal strip and identifying the correct accessories.
305801/XX5 (SUPU): marking labels for terminal blocks, numbers 41–50. For building the terminal strip and identifying the correct accessories.
305801/XX6 (SUPU): marking labels for terminal blocks, numbers 51–60. For building the terminal strip and identifying the correct accessories.
305801/XX7 (SUPU): marking labels for terminal blocks, numbers 61–70. For building the terminal strip and identifying the correct accessories.
305801/XX8 (SUPU): marking labels for terminal blocks, numbers 71–80. For building the terminal strip and identifying the correct accessories.
305801/XX9 (SUPU): marking labels for terminal blocks, numbers 81–90. For building the terminal strip and identifying the correct accessories.
305801/X10 (SUPU): marking labels for terminal blocks, numbers 91–99. For building the terminal strip and identifying the correct accessories.
305801 (SUPU): marking labels for terminal blocks, blank. For building the terminal strip and identifying the correct accessories.
303101 (SUPU): end plate for terminal block 303. For building the terminal strip and identifying the correct accessories.
305801/XX1 (SUPU): marking labels for terminal blocks, numbers 1–10. For building the terminal strip and identifying the correct accessories.
303121 (SUPU): end plate for two-level terminal block 303921. For building the terminal strip and identifying the correct accessories.
303302 (SUPU): conductive jumper for terminal series 303. For building the terminal strip and identifying the correct accessories.
303901 (SUPU): feed-through screw terminal block 2.5mm², grey, 24A/800V. Overview of wiring, applications and accessories.
303902 (SUPU): feed-through screw terminal block 2.5mm², blue, 24A/800V. Overview of wiring, applications and accessories.
303921 (SUPU): two-level screw terminal block 2.5mm², 2 separate circuits, 24A/500V. Overview of wiring, applications and accessories.
303903 (SUPU): protective PE screw terminal block 2.5mm², green-yellow. Overview of wiring, applications and accessories.
Prices include the recycling fee.
The range includes simple types 303901, 303902 and 303903, the two-level terminal 303921, end plates, the jumper 303302 and marking labels of the 305801. series A different number of levels means different requirements for marking and for finishing the assembly.
Turning the screw generates the clamping force needed for electrical contact. The result depends on correct seating of the conductor, the design of the pressure part and the prescribed tightening. It is not correct to add force just because the conductor has a larger cross-section. Over-tightening can damage the terminal, under-tightening can create an unreliable contact. Use the tool and torque intended for the specific type.
When preparing a strand, individual wires must not escape outside the clamping space. The ferrule must match the cross-section and the contact geometry; its collar must not prevent full insertion. The general recommendation “always with a ferrule” does not replace the manufacturer's table and cannot be used to extend the permitted range.
The primary SUPU data sheet 303921 states screw connection, two levels and four connection points. The ranges are 0.2–4 mm² for solid conductor, 0.2–2.5 mm² for stranded without ferrule and 0.25–2.5 mm² for stranded with ferrule.
V details of 303921 the upper and lower connections are described as separate paths for two different signals. The four connected conductors therefore do not represent four independent feed-through circuits or one common four-conductor node.
This is practical when grouping two conductors belonging to the same device. In the diagram and on the terminal block marking, however, the upper and lower positions must be distinguished. The body number alone is not enough if two different potentials are hidden under it. For example, choose an unambiguous suffix with the level letter and use the same system at both ends of the line.
Our own model contains twelve devices, each with two conductors that need a separate feed-through path. In total, this is 24 paths and 48 terminated ends: an input and an output on each path. Arranging two separate paths in one body requires twelve bodies instead of twenty-four single-path ones. The calculation does not compare the actual width of the products and does not attribute double current-carrying capacity to the entire assembly.
303121 is explicitly limited in the range to the terminal 303921. The detail of terminal 303921 also lists the conductive bridge 240601. as compatible. When choosing accessories, the common designation 2.5 mm² is therefore not sufficient.
For the bridge, determine which adjacent positions are to share a potential and on which level. Do not connect both height levels just because they belong to the same device. Common sections must handle the sum of the loads, and their permitted current may be lower than the value of an individual terminal. Do not assign a protective function by merely changing the colour of the label.
The maintenance procedure should be based on the manufacturer's instructions and the equipment conditions. Arbitrary repeated over-tightening can damage the connection. During intervention, work without voltage, check the condition of the termination and follow the prescribed mounting procedure.
No. The current is limited by the entire circuit, including the conductor and its installation, jumpers and protection. To compare different designs, use the overview Terminals and terminal blocks; the numerical cross-section is not a universal current recommendation.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.