9771 (1-30), ONKA, marking labels for terminal blocks, 1–30
9771 (1-30) (ONKA): marking labels for terminal blocks, 1–30. For building the terminal strip and identifying the correct accessories.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
ONKA triple-level spring terminals and accessories for space-saving sensor connection. Choose by cross-section and level bridging.
9771 (1-30) (ONKA): marking labels for terminal blocks, 1–30. For building the terminal strip and identifying the correct accessories.
9771 (31-60) (ONKA): marking labels for terminal blocks, 31–60. For building the terminal strip and identifying the correct accessories.
1929 (ONKA): conductive jumper for the matching terminal series. For building the terminal strip and identifying the correct accessories.
1852 (ONKA): three-level spring terminal block 2.5mm², 24A/750V. Overview of wiring, applications and accessories.
Prices include the recycling fee.
The basis of this category is ONKA 1852; the range is complemented by the bridging comb 1929 and a pack of marking labels 9771. The term “triple” expresses the spatial design, not automatically a common potential of all connected conductors.
ONKA 1852 is listed by the manufacturer as a three-level Push-in terminal 2.5 mm². The manufacturer separately distinguishes the internally bridged type 1862 and the earth type 1872; these functions cannot be attributed to 1852 just based on a similar appearance.
When designing, distinguish the body, level, connection point and electrical path. The body occupies one position in the row, the levels divide its height and the clamping points accept the conductor ends. Only the diagram determines which points are conductively connected. Three levels therefore do not by themselves prove three insulated circuits, their common connection or the presence of a protective contact.
A multi-level design can keep related cores close together and make the link to a specific cable clearer. At the same time, it increases the demands on marking and access to the lower levels. If the upper conductors cover the actuation of the lower contacts, service intervention becomes unnecessarily difficult. Plan the routing of the cores before the cable duct is finally filled.
Among the accessories for 1852 the manufacturer lists 1929 for twenty positions; the same comb 1929 is in the TECHNOLINE range. The selected comb must be used in the intended bridging point, not as a general connection of all levels.
Before mounting, draw every common node in the diagram. Bridging adjacent terminals on one level and connecting different levels are two different changes to the circuit. Even if the comb fits mechanically, the series, pitch and prescribed position must be observed. Do not shorten or modify contacts without the manufacturer's procedure.
Our own organisational model counts on eight three-level bodies, i.e. 8 × 3 = 24 level addresses. Adding two spare bodies extends the list to thirty addresses. Marking such as X1:05-A, X1:05-B and X1:05-C distinguishes three levels of the same position. The number of addresses does not indicate the number of electrically independent paths; that must be assigned according to the actual diagram. The model helps prepare labels and a checklist, not determine the current load.
For each conductor, assess the type of core and termination. The 2.5 mm² category alone is not enough to determine the range for a bare fine strand or a strand with a ferrule. The ferrule length, crimp shape and full insertion are also important. Route the supply conductors so that they do not pull on the contact and do not prevent safe operation of neighbouring points.
The current limits of individual levels do not add up on one common supply. If several branches are bridged by a comb, its permitted load, the sum of the loads and the temperature conditions are also decisive. A tighter arrangement of circuits is no reason to overlook the heating of the entire assembly.
No. The protective function must be provided by the specific design and wiring. The position, conductor colour or a green-yellow label alone do not create a protective connection to the rail.
Use marking of both position and level and the same identification in the documentation. Before measuring, check which point the instrument is actually accessing; the physically nearest opening may not belong to the monitored path.
If access is more important than density, compare SUPU single-level designs 2.5 mm² and screw variants. Choose the replacement according to electrical function and space, not just according to the number of openings.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.