Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110
Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Process sensors measure pressure, temperature, flow and level in pipes and tanks. Here you will find pressure sensors in relative and absolute versions with G1/4 and G1/2, thread, Pt100 and Pt1000 temperature sensors including thermowells and compression fittings, flow meters for water, air and aggressive media, and float, capacitive and ultrasonic level sensors. Most models offer an analogue 4–20 mA or 0–10 V output for direct connection to a PLC; on switching versions the limit can be set on the device display. You can choose by measuring range, accuracy, material of the wetted parts, permissible media temperature and degree of protection up to IP69K. We supply sensors from TECHNOLINE, SICK, IFM and other brands. If needed, contact us and we will gladly help you choose the type for your application.
Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110
Pressure sensor, thread G1/4", for pressure 400 bar, output 0-10V, PB1116
Pressure sensor, thread G1/4", for pressure 5 bar, output 4-20mA, PB1103
Pressure sensor, thread G1/4", for pressure 20 bar, output 4-20mA, PB1107
Pressure sensor, thread G1/4", for pressure 50 bar, output 4-20mA, PB1109
Pressure sensor, thread G1/2", for pressure 2 bar, output 4-20mA, 2PB1101
Pressure sensor, thread G1/2", for pressure 2 bar, output 0-10V, 2PB1102
Pressure sensor, thread G1/2", for pressure 5 bar, output 0-10V, 2PB1104
Pressure sensor, thread G1/2", for pressure 10 bar, output 0-10V, 2PB1106
Pressure sensor, thread G1/2", for pressure 20 bar, output 0-10V, 2PB1108
Pressure sensor, thread G1/2", for pressure 50 bar, output 0-10V, 2PB1110
Pressure sensor, thread G1/2", for pressure 5 bar, output 4-20mA, 2PB1103
pressure sensor; thread: G1/2"; for pressure 20 bar; output: 4-20mA; Ema Elecronic
Pressure sensor, thread G1/2", for pressure 50 bar, output 4-20mA, 2PB1109
ISE20B-T-01 SMC – digital pressure sensor, 0.1 to 1 MPa, PNP open collector 2 outputs + Analogue voltage output. Industrial product for automation, measurement and control.
ISE20B-R-M-M5 SMC – digital pressure and vacuum sensor, -0.1 to 1 MPa, NPN open collector 2 outputs + Analogue voltage output. Industrial product for automation.
ISE20B-T-M-M5 SMC – digital pressure sensor, 0.1 to 1 MPa, PNP open collector 2 outputs + Analogue voltage output. Industrial product for automation, measurement and control.
Pressure sensor, thread G1/4", for pressure 100 bar, output 0-10V, PB1112
Pressure sensor, thread G1/4", for pressure 200 bar, output 0-10V, PB1114
Pressure sensor, thread G1/4", for pressure 250 bar, output 0-10V, PB1120
Pressure sensor, thread G1/4", for pressure 100 bar, output 4-20mA, PB1111
Pressure sensor, thread G1/4", for pressure 200 bar, output 4-20mA, PB1113
Pressure sensor, thread G1/4", for pressure 250 bar, output 4-20mA, PB1120
Pressure sensor, thread G1/4", for pressure 400 bar, output 4-20mA, PB1115
Pressure sensor, thread G1/2", for pressure 100 bar, output 0-10V, 2PB1112
Ceny zawierają opłatę recyklingową.
Process measurement should provide information on which a specific process can be controlled: topping up a tank, verifying cooling, regulating pressure or monitoring the composition of a medium. The first question is therefore not the sensor brand but the decision its signal is to support. To stop filling, detecting that a level has been reached may be enough; to record consumption, you need continuous measurement and correctly configured logging. Confusing these tasks leads to a device that responds but does not provide the data needed.
Siemens gas analysers include the OXYMAT, ULTRAMAT and CALOMAT series. When choosing, ask not only about the monitored component but also about the rest of the gas mixture. The same oxygen content in different accompanying gases is not automatically the same measuring task.
Level sensors and probes include float switches, submersible pressure probes and radar devices. Decide whether you need a limit state, level height or volume. Height and volume are directly proportional only in a tank with a constant horizontal cross-section.
Category pH measurement contains the Orbipac CPF81D pH sensor and the Smartec CLD134. conductivity device. These are different quantities: the conductivity value alone does not determine the acidity or alkalinity of an unknown mixture.
Flow sensors offer IFM SI flow monitors, SM magnetic-inductive devices and the Prosonic Flow 91W. ultrasonic meter. To confirm flow and to totalise pumped litres, choose according to the different requirements for output and measuring function.
Temperature sensors include TECHNOLINE and ENDA Pt100 probes as well as a ring-lug thermocouple. The resistance input for Pt100 and the millivolt thermocouple input are not interchangeable. Besides the electronics, thermal contact with the measured point is decisive.
Pressure sensors include, for example, devices from IFM, SMC and Ema. Separate the pressure reference from the design of the measuring cell: absolute or relative pressure describes what the measurement is referenced to; ceramic or a metal diaphragm describes the sensor design.
Turbidity measurement are represented in the range by the Turbimax CUE21-A1S. Turbidity is an optical quantity; without a verified correlation for the specific suspension, it does not give the mass of suspended solids or direct proof of the health safety of water.
Write down the normal minimum and maximum, start-up, shutdown and cleaning. The device must handle the actual operating state, but an unnecessarily wide range can reduce the usability of the measurement in the working area. For accuracy, distinguish between percent of measured value and percent of span. The number of decimal places on the display alone says nothing about the uncertainty of the result. Also include sensor location, drift, the transmitter and the control system input in the assessment.
The principle must match the medium. For example IFM datasheet SM6000 specifies a liquid conductivity of at least 20 µS/cm. This requirement belongs to this model, not automatically to all flow meters. When the liquid changes, keeping the same thread or the same current output is therefore not enough.
For the material check, make a list of all wetted parts: diaphragm, electrodes, seals, flow chamber, cable sheath and adhesives if they come into contact with the medium. Assess concentration, temperature and exposure time, including cleaning agents. A resistant outer housing does not mean a resistant measuring path. A thread with the same designation does not yet confirm the correct sealing method. For pressure equipment, also check surges, vacuum and the combination of temperature and pressure.
Distinguish between the sensing element itself, the sensor with transmitter and the complete measuring system. Orbipac CPF81D according to the manufacturer uses Memosens; the digital connection of this sensor is not a synonym for an ordinary current loop. The input type, cable and any transmitter must form a compatible assembly.
For analogue transmission, check the supply, active or passive input, permissible load and diagnostic states. For a switching output, verify polarity, load capacity and hysteresis setting. If communication fails, the control program must distinguish an invalid value from a genuinely unchanging process. The last received number without a data-age flag can look plausible long after a measurement failure.
Plan acceptance of the assembly before ordering. Determine how you will verify several working points, the correctness of displayed units and the response to a fault. Also prepare a configuration record, sensor identification and space for service notes. This makes it possible to distinguish a real process change from a change of measurement settings during later replacement.
Consider only an illustrative linear transmitter with a range of 0–10 bar and a 4–20 mA output. For a current of 12 mA, p = (12 − 4) / (20 − 4) × 10 = 5 bar. If the control system input mistakenly used a range of 0–16 bar, it would display 8 bar. The difference of 3 bar arises from configuration, not from a sensor error. The example does not represent the parameters of any product offered.
No. Also compare the reference of the quantity, materials, dynamics, mounting position, supply and output. Replacement is complete only after verifying the entire measuring path, including correct units in the record and the meaning of alarms. Document the configuration of the original device first so that any change in the trend can be explained.
According to the criticality of the measurement, experience with drift and operating load, not by a single universal interval. Prepare access for checking, safe isolation from the process and records of interventions. Calibration compares the indication with a reference; adjusting the device is a separate step. Verifying one point does not prove the correctness of the whole range.
No. An ordinary measuring signal alone does not establish suitability for personal protection or for use in explosive atmospheres. Such an application requires an appropriate design and documentation of the exact version of the entire assembly. The general series name or the range of communication functions does not replace this check.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.