SUPU miniature modular terminals up to 1.5mm
The category contains SUPU miniature two-conductor terminals 240303 and 240304, version 240307 and related accessories. The selection should start with a plan of the entire assembly: the terminal itself, the end of the row, fastening and any bridging are different parts.
A small terminal needs its own mounting concept
The SUPU data sheet for series 240 describes single-level feed-through terminals with side connection and spring contact. It lists the end plate 240621, adapter 241019 and adjacent jumper 240601. The colour variants also include order codes 240303, 240304 and 240307.
Side entry of the conductors affects the space actually required. In addition to the body dimensions, allow for the bend of the core, access to the contact actuator and space to read the marking. Terminals squeezed between the box wall and the cable bundle may be accessible during the first wiring, but difficult to service when replacing a single conductor.
Adapter 241019 is intended in the range for types 240303, 240304 and 240307; TECHNOLINE recommends two adapters for an assembly of ten to twenty terminals. End plate 240621 has a different role than the mechanical adapter.
A feed-through connection is not automatically a protective connection to the rail
The two conductors of a feed-through point create electrical continuity in the relevant node. Adjacent terminals have their own function until you deliberately connect them with a jumper. When designing, therefore separate the mechanical row from the electrical groups: being adjacent on the rail does not mean a common potential.
A green-yellow version is not in itself proof of a conductive connection to the DIN rail. Determine the protective path according to the design purpose of the specific part and the wiring; plastic accessories may only hold the assembly. The documentation should make it clear where the protective connection actually runs and which connections are opened during disassembly.
Model of the reserve for a small connection box
Our own design model counts on fourteen separate feed-through positions and a twenty-percent reserve. The reserve comes to 14 × 0.20 = 2.8 positions; rounding up gives three, so seventeen positions in total. This is not a calculation of the length of the finished assembly: it must be supplemented by the actual dimensions of the fastening and end pieces. Mark the free positions as spare and keep access to them, otherwise their future use becomes complicated.
Choice of conductor and completion of the assembly
The nominal cross-section in the category name is not a universal figure for all termination methods. Before mounting, distinguish between a bare strand and a strand with a ferrule, check the stripping length and the dimension of the crimped end. In a miniature body, it is also important whether the insulating collar prevents full insertion. Do not insert two conductors into one contact just because they seem thin enough.
When using adjacent jumpers, draw the beginning and end of each group. The common supply must handle the sum of the loads, not just the current of one branch. In addition to the terminals, the load capacity of the assembly is also limited by the jumper, the conductors, their installation and protection. Miniaturisation does not change these electrical requirements.
FAQ
Will an adapter replace an end plate?
No. Fastening and closing the side are different functions. When ordering, list the parts according to the assembly drawing, not just according to the number of connected conductors.
Is this series a direct replacement for standard DIN terminals?
Compare the mounting parts, connection direction, tool access and accessories. In the overview terminals and terminal blocks choose the design according to the entire space, not just the cross-section. The same brand does not guarantee the same fastening or jumper pitch.