LA33LUM320, EMAS, safety actuator key, safety key, for L5 / L51 / L52 / L53
LA33LUM320 EMAS – safety actuator key. Technical parameters, application and compatibility check.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Key-operated safety switches without electrical locking for monitoring protective doors and guards. Choose by actuator, contacts and housing.
LA33LUM320 EMAS – safety actuator key. Technical parameters, application and compatibility check.
LA33LUM321 EMAS – safety actuator key. Technical parameters, application and compatibility check.
LA33LUM323 EMAS – safety actuator key. Technical parameters, application and compatibility check.
LA33LUM324 EMAS – safety actuator key. Technical parameters, application and compatibility check.
L5K23LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K27LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.
L5K25LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K25LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
Ceny zawierają opłatę recyklingową.
A key-operated switch is used for monitoring a movable guard: a counterpart connected to the door enters the actuator head. When selecting, first describe the required function. Do you need to detect that the guard is closed, or also prevent it from being opened during hazardous movement? For this category, the need for guard locking must be assessed separately. An inserted key alone does not prove that the door will remain locked until run-down has ended.
The public TECHNOLINE range includes L5K25LUM321. Its separate EMAS sheet states an angled metal key, a plastic housing and slow-action contacts 1NO + 2NC. When replacing, compare the complete order code, not just the shape of the red head.
In the enquiry, include the door opening method, switch location, cable space and the required contact diagram. For a hinged guard, draw the path of the counterpart; for a sliding one, its guidance. The door may look correct in the closed position but approach the switch at an unsuitable angle during the last part of the movement. The course of the entire insertion and withdrawal is decisive.
Use the prescribed counterpart and a separate door stop. The key must not carry the weight of the door or compensate for faulty hinges. These principles are clearly explained in OMRON mounting instructions for key-operated switches; the specific dimensions and limits are always determined by the instructions for the selected EMAS.
For practical adjustment, make a record of three states: door loosely closed, door pressed with normal force and door loaded within the limits of expected use. In each state, observe the position of the counterpart relative to the head. Such a record will help distinguish a shifted switch from a sagging guard. Repeat the check after tightening the joints.
For a practice design, assume a lateral deviation of the hinge of 0.4 mm, the bracket 0.3 mm and the counterpart fastening 0.2 mm. With an unfavourable combination we get 0.4 + 0.3 + 0.2 = 0.9 mm. Correcting the bracket to reduce its contribution to 0.1 mm reduces the sum to 0.7 mm.
The figures are our own model assumptions, not the tolerances of L5K25LUM321. Even a smaller result does not by itself confirm suitable mounting: it must be compared with the permitted misalignment of the specific assembly. The example teaches you to look for the cause of the deviation in individual parts and not to solve the whole problem by forcibly pulling the switch towards the door.
At handover, record the counterpart identification, bracket position and functional test results. Check the behaviour on opening and on subsequent closing. Information about a closed guard must not be mistaken for a start command without assessing the design; the importance of this distinction is emphasised by OMRON in its door switch application guidelines.
No. The required level is demonstrated by the design and verification of the entire safety function, including wiring, evaluation and machine response.
If the design transmits hinge rotation well, study Hinge Switches. For a broader choice of mechanism and the link to the protective function, see Safety Limit Switches. A change of principle requires a new assessment of mounting and function.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.