Key-Operated Safety Switches - without Electrical Locking

Key-operated safety switches without electrical locking for monitoring protective doors and guards. Choose by actuator, contacts and housing.

Filtry
Znaleziono 9 produktów
DOSTĘPNY

LA33LUM321, EMAS, safety actuator key, bent key, for L5 / L51 / L52 / L53

Nr kat.: LA33LUM321

LA33LUM321 EMAS – safety actuator key. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
1,72 €
bez VAT · 2,08 € z VAT
NASZA PORADA DOSTĘPNY

LA33LUM323, EMAS, safety actuator key, flexible key, for L5 / L51 / L52 / L53

Nr kat.: LA33LUM323

LA33LUM323 EMAS – safety actuator key. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
2,62 €
bez VAT · 3,18 € z VAT
NASZA PORADA DOSTĘPNY

LA33LUM324, EMAS, safety actuator key, flexible key, for L5 / L51 / L52 / L53

Nr kat.: LA33LUM324

LA33LUM324 EMAS – safety actuator key. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
3,53 €
bez VAT · 4,27 € z VAT
NASZA PORADA DOSTĘPNY

L5K23LUM322, EMAS, L5, safety limit switch, plastic body, safety actuator - straight key, 1 NC + 1 NO, slow action, IP65

Nr kat.: L5K23LUM322

L5K23LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
9,76 €
bez VAT · 11,81 € z VAT
NASZA PORADA DOSTĘPNY

L5K23LUM321, EMAS, L5, safety limit switch, plastic body, safety actuator - bent key, 1 NC + 1 NO, slow action, IP65

Nr kat.: L5K23LUM321

L5K23LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
9,76 €
bez VAT · 11,81 € z VAT
NASZA PORADA DOSTĘPNY

L5K27LUM321, EMAS, L5, safety limit switch, plastic body, safety actuator - bent key, 1 NC + 2 NO, slow action, IP65

Nr kat.: L5K27LUM321

L5K27LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
11,94 €
bez VAT · 14,44 € z VAT
NASZA PORADA DOSTĘPNY

L5K25LUM322, EMAS, L5, safety limit switch, plastic body, safety actuator - straight key, 2 NC + 1 NO, slow action, IP65

Nr kat.: L5K25LUM322

L5K25LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

Dostępny 5 i więcej szt.
11,94 €
bez VAT · 14,44 € z VAT
NASZA PORADA

L5K25LUM321, EMAS, L5, safety limit switch, plastic body, safety actuator - bent key, 2 NC + 1 NO, slow action, IP65

Nr kat.: L5K25LUM321

L5K25LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

Na zapytanie
11,94 €
bez VAT · 14,44 € z VAT

Ceny zawierają opłatę recyklingową.

Key-Operated Safety Switches - without Electrical Locking

A key-operated switch is used for monitoring a movable guard: a counterpart connected to the door enters the actuator head. When selecting, first describe the required function. Do you need to detect that the guard is closed, or also prevent it from being opened during hazardous movement? For this category, the need for guard locking must be assessed separately. An inserted key alone does not prove that the door will remain locked until run-down has ended.

Specific version and choice of counterpart

The public TECHNOLINE range includes L5K25LUM321. Its separate EMAS sheet states an angled metal key, a plastic housing and slow-action contacts 1NO + 2NC. When replacing, compare the complete order code, not just the shape of the red head.

In the enquiry, include the door opening method, switch location, cable space and the required contact diagram. For a hinged guard, draw the path of the counterpart; for a sliding one, its guidance. The door may look correct in the closed position but approach the switch at an unsuitable angle during the last part of the movement. The course of the entire insertion and withdrawal is decisive.

Mounting starts at the door

Use the prescribed counterpart and a separate door stop. The key must not carry the weight of the door or compensate for faulty hinges. These principles are clearly explained in OMRON mounting instructions for key-operated switches; the specific dimensions and limits are always determined by the instructions for the selected EMAS.

For practical adjustment, make a record of three states: door loosely closed, door pressed with normal force and door loaded within the limits of expected use. In each state, observe the position of the counterpart relative to the head. Such a record will help distinguish a shifted switch from a sagging guard. Repeat the check after tightening the joints.

Author's example: lateral sum of tolerances

For a practice design, assume a lateral deviation of the hinge of 0.4 mm, the bracket 0.3 mm and the counterpart fastening 0.2 mm. With an unfavourable combination we get 0.4 + 0.3 + 0.2 = 0.9 mm. Correcting the bracket to reduce its contribution to 0.1 mm reduces the sum to 0.7 mm.

The figures are our own model assumptions, not the tolerances of L5K25LUM321. Even a smaller result does not by itself confirm suitable mounting: it must be compared with the permitted misalignment of the specific assembly. The example teaches you to look for the cause of the deviation in individual parts and not to solve the whole problem by forcibly pulling the switch towards the door.

Common mistakes and FAQ

At handover, record the counterpart identification, bracket position and functional test results. Check the behaviour on opening and on subsequent closing. Information about a closed guard must not be mistaken for a start command without assessing the design; the importance of this distinction is emphasised by OMRON in its door switch application guidelines.

Is a pair of normally closed contacts a guarantee of PL or SIL?

No. The required level is demonstrated by the design and verification of the entire safety function, including wiring, evaluation and machine response.

When should a different guard sensing method be compared?

If the design transmits hinge rotation well, study Hinge Switches. For a broader choice of mechanism and the link to the protective function, see Safety Limit Switches. A change of principle requires a new assessment of mounting and function.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.