Filter regulator

Filter regulators remove contaminants and condensate and set the working pressure in one unit. Choose by port, flow and filtration grade.

Filtry
Znaleziono 16 produktów
DOSTĘPNY

TEAW2000-02-D, filter regulator with pressure gauge, flow rate 550Nl/min, working pressure 0-1MPA, connection G1/4 inch, TECHNOLINE

Nr kat.: TEAW2000-02-D

TEAW2000-02-D, filter regulator with pressure gauge, flow rate 550Nl/min, working pressure 0-1MPA, connection G1/4 inch, TECHNOLINE

Dostępny 5 i więcej szt.
33,59 €
bez VAT · 40,64 € z VAT
DOSTĘPNY

TEAW-3000-03-D, filter regulator, TECHNOLINE

Nr kat.: TEAW-3000-03-D

filter regulator with pressure gauge

Dostępny 5 i więcej szt.
34,45 €
bez VAT · 41,68 € z VAT

ZFC53-B-X04, SMC, in-line vacuum filter with push-in fittings

Nr kat.: ZFC53-B-X04

ZFC53-B-X04, SMC, in-line vacuum filter with push-in fittings. The vacuum filter protects the vacuum system from contaminants drawn in from the process.

Na zapytanie
14,97 €
bez VAT · 18,11 € z VAT

ZFC74-B, SMC, in-line vacuum filter with push-in fittings

Nr kat.: ZFC74-B

ZFC74-B, SMC, in-line vacuum filter with push-in fittings. The vacuum filter protects the vacuum system from contaminants drawn in from the process.

Na zapytanie
15,17 €
bez VAT · 18,36 € z VAT

ZFC7D-B-X04, vacuum filter, SMC

Nr kat.: ZFC7D-B-X04

vacuum filter; operating pressure: -100kPa - 1MPa; flow rate: 250 l/min; SMC

Na zapytanie
17,22 €
bez VAT · 20,84 € z VAT

AF40-F04-D, SMC, compressed air filter, modular version

Nr kat.: AF40-F04-D

AF40-F04-D, SMC, compressed air filter, modular version. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.

Na zapytanie
45,07 €
bez VAT · 54,53 € z VAT

AFD20-F02C-A, SMC, micro mist separator

Nr kat.: AFD20-F02C-A

AFD20-F02C-A, SMC, micro mist separator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.

Na zapytanie
50,03 €
bez VAT · 60,54 € z VAT

AW20-N02BG-D, filter regulator, SMC

Nr kat.: AW20-N02BG-D

AW20-N02BG-D, filter regulator, SMC

Na zapytanie
56,18 €
bez VAT · 67,98 € z VAT

AMF350C-F4-R, activated carbon filter, SMC

Nr kat.: AMF350C-F4-R

AMF350C-F4-R, activated carbon filter, SMC

Na zapytanie
90,22 €
bez VAT · 109,17 € z VAT

AME350C-F04B-R, micro mist separator, SMC

Nr kat.: AME350C-F04B-R

AME350C-F04B-R, micro mist separator, SMC

Na zapytanie
94,32 €
bez VAT · 114,13 € z VAT

LFR-1/4-D-MINI, Festo, pressure reducing valve with filter

Nr kat.: LFR-1/4-D-MINI

LFR-1/4-D-MINI, Festo, pressure reducing valve with filter. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Na zapytanie
104,98 €
bez VAT · 127,03 € z VAT

SFD100-C04, SMC, clean room filter

Nr kat.: SFD100-C04

SFD100-C04 SMC – clean room filter. When selecting, verify the connection, size and other parameters of the specific variant.

Na zapytanie
126,31 €
bez VAT · 152,83 € z VAT

FRC-1/4-D-MINI, Festo, compressed air preparation unit

Nr kat.: FRC-1/4-D-MINI

FRC-1/4-D-MINI, Festo, compressed air preparation unit. It is a specific industrial component or accessory intended for the given product series.

Na zapytanie
177,57 €
bez VAT · 214,86 € z VAT

AF811-N1, SMC, high-flow filter

Nr kat.: AF811-N1

AF811-N1 SMC – high-flow filter. When selecting, verify the connection, size and other parameters of the specific variant.

Na zapytanie
332,17 €
bez VAT · 401,93 € z VAT

Ceny zawierają opłatę recyklingową.

Filter regulators

A filter regulator combines the removal of specified contaminants with control of the outlet pressure. The filtration capacity and flow characteristic are assessed separately. Condensate, pressure drop and maintenance affect the function of the whole branch, not just its static pressure.

Selection data Filter regulators

Step What to document
Identification filter version and condensate drainage
Operating requirements flow rate and working pressures
Acceptance pressure drop and filter condition

Choose a filter regulator according to two separate requirements: how to prepare the air and what pressure should be available at the outlet. For the specification, we recommend also stating the installation location, usual consumption and the method of condensate drainage. If you write these points down before choosing the size, you will more easily distinguish the properties needed for the process from the mere connection size.

What the combined element actually does

The SMC manual AW-D describes the removal of solid contaminants and liquid water together with pressure regulation. For this series, it specifies a filtration rating of 5 µm. The offered AW20-N02BG-D has an NPT thread according to the order table; the letter F designates a different G thread version. Therefore, do not assess the same fraction in inches without the thread type.

The listing also includes TEAW2000-02-D, TEAW1000-M5 and TEAW-3000-03-D from TECHNOLINE. The range further consists of ZFC, AF, AFD, AMF, AME, SFD, AMH, AF811 and Festo LFR and FRC. For selection, we recommend starting with the full code and verifying the required function in a separate document. The parameters described for AW-D do not automatically apply to all these items.

Condensate, filtration and service

For AF-D, SMC prescribes checking the filter element; clogging can increase the pressure loss and limit the flow. Condensate should be drained before it reaches the element. The manual distinguishes manual drainage from the float auto drain and points out the pressure conditions for its operation. If the drain does not work, the mounting position and the passage of the drain line are also checked.

For AW-D, the manufacturer requires the equipment to be depressurised before dismantling. Regularly check the plastic bowl for damage; the manual allows a neutral cleaning agent for washing it. Leave space in the assembly for removing the bowl and access to the drain. The specific service procedure must correspond to the supplied variant, including the bowl locking method.

Our own procedure for choosing the assembly

First compare the machine requirement with the documented properties of the selected element. Then draw where the measuring points will be accessible. If you are designing a separate filter upstream of regulator, this arrangement allows both stages to be assessed separately. For a combined part, determine in advance which measurements are actually available, so that diagnostics do not promise a value that cannot be read.

Model calculation of the change in pressure loss

This is our own model of a standalone filter, not the parameters of AF or AW. At the same specified flow rate of 360 l/min and the same reference conditions, the pressure upstream of the filter was 0.70 MPa and downstream 0.68 MPa at commissioning. After some time we measure 0.70 and 0.64 MPa. The original loss was 0.02 MPa, now it is 0.06 MPa; the increase is therefore 0.04 MPa.

This model provides a reason for checking, not an automatic instruction to replace. Before drawing a conclusion, we recommend repeating the measurement and verifying the same consumption. With a combined filter regulator, the difference between inlet and outlet also includes the intentional pressure reduction, so it cannot all be attributed to a clogged element.

FAQ

Does a standard filter replace a dryer?

Such a conclusion does not follow from the filtration rating. For excessive humidity, the AF-D manual assumes an upstream dryer or aftercooler. Address the drying requirement separately.

Can flow rates be compared without further data?

For the design, we recommend requiring the same reference conditions and the corresponding pressure point. Without them, it is not clear whether the compared numbers describe the same situation.

Primary sources: SMC AW-D a SMC AF-D.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.