Control cabinet cooling, heating and lighting – filter fans, heaters, thermostats and lights. Choose by the cabinet heat balance, dimensions and supply.
PFI1000FILTER, PLASTIM, replacement filter mat
PFI2500FILTER, PLASTIM, replacement filter mat
Lidokov lockable lock for closing the door of an electrical control cabinet. It is supplied with a key and allows access to the internal electrical equipment to be restricted.
PTM110, EMAS, mechanical control cabinet thermostat for heating, NC contact. Mechanical thermostat for switching control cabinet heating according to the set temperature.
PTM111, EMAS, single thermostat for switching ventilation, 1×NO, DIN mounting
PFI1000, PLASTIM, filter grille for control cabinets, 120×120×20.5mm, IP54, RAL7035. PLASTIM filter grille PFI1000 for air inlet or outlet in a control cabinet; a hole of 92×92mm. is required for…
PTM122, EMAS, double thermostat for controlling heating and ventilation, 1×NO + 1×NC, DIN mounting
PFI1500, PLASTIM, filter grille, 160×160mm
PTVT, EAE, control cabinet thermostat for switching on ventilation 230VAC, 0-60°C, 230 V AC
PFI2500, PLASTIM, filter grille for control cabinets, 260×260×31mm, IP54, RAL7035. PLASTIM filter grille PFI2500 for air inlet or outlet in a control cabinet; a hole of 223×223mm. is required for…
PTF1000, PLASTIM: control cabinet filter fan 230VAC with an airflow of 30m³/h and a power consumption of 14W, protection rating IP54.
The EAE EGKL24V-50 luminaire provides lighting for the interior of an electrical control cabinet. The version is designed for a 24VDC supply and has a length of 500mm.
EGKL50, EAE, LED control cabinet lighting, length 50cm, 3W, 220VAC, 220 V AC, 3 W
PTF1500, PLASTIM, filter fan for control cabinet, 100m³/h, 230VAC, IP54. The PLASTIM filter fan PTF1500 supports air exchange in a control cabinet with a filtered inlet.
HGL046, TECHNOLINE, fan heater for heating control cabinets, supply 230VAC, power 400W, protection rating IP20.
PTF2500, PLASTIM, filter fan, 115m³/h, 260×260mm, 230VAC
PTF3500, PLASTIM, filter fan, 240m³/h, 260×260×103mm, 230VAC
PTF4500, PLASTIM: control cabinet filter fan 230VAC, airflow with filter 650m³/h (without filter 900m³/h), IP54, 260×260×111mm.
PFI1500FILTER, PLASTIM, replacement filter mat
SZ 2500.400, Rittal, connection cable for system LED lighting, 3m, 100–240VAC, 3-pole
PFI3500, PLASTIM: ventilation grille for air inlet or outlet in a control cabinet, dimensions 325×325mm, IP54, RAL7035.
2500210, Rittal, system LED luminaire for control cabinet, 900lm, 11W, Schuko, IP20. Rittal SZ 2500210 is a system LED light for control cabinets with an integrated Schuko socket.
Ceny zawierają opłatę recyklingową.
Choose control cabinet accessories according to three separate needs: dissipating heat losses, protection against adverse temperature and humidity conditions, and visibility during maintenance. A fan, a heater and a luminaire are not interchangeable components. Add the enclosure environment, the operating mode of the devices and the power supply available for auxiliary circuits to the brief.
The range includes Plastim PTF, PFI and separate replacement filters. Plastim catalogue 2020, page 29, distinguishes the passive PFI1000 from the fan models PTF1000 and PTF1000T; the last two versions also differ in connection method. This is period documentation for distinguishing the parts, not a guarantee of the identical revision of the current delivery.
If you are ordering replacement filter material, verify the size and suitability for the existing frame. The mat alone does not replace a complete fan. For a fan, compare the power supply, mounting cut-out, airflow direction and the conditions of the stated airflow. Do not use the figure without knowing the filtration arrangement as a certain flow through the finished control cabinet.
STEGO describes filtered ventilation as supplying cooler ambient air and removing heated air from the enclosure. This implies an important limit: ventilation alone cannot achieve a temperature below the temperature of the intake air. For the design, the highest temperature at the intake point is therefore important, not just the usual room temperature.
The arrangement of components should allow air to pass through the necessary places. A design in which the flow bypasses only part of the assembly may not solve local overheating. Take into account access to the filter for cleaning and replacement. Set the maintenance interval according to the actual contamination and operation, not as a universal number for all installations.
Consider ideal removal of 100 W of heat by an airflow of 60 m³/h. For the chosen density of 1.2 kg/m³ and specific heat capacity of 1 000 J/(kg·K), the mass flow is 0.02 kg/s. From the equation P = ṁ · c · ΔT, the temperature rise of the flowing air is approximately 5 K. A difference of 5 K corresponds to a difference of 5 °C, not to the absolute temperature inside the enclosure.
This is a simplified author's example, not the sizing of a specific PTF. It does not include pressure losses, filter contamination, local hot spots or heat exchange through the walls. The actual design must work with the data of the assembly and the manufacturer. The calculated flow does not verify the protection rating or the suitability of the ambient air supply.
For a heating element, first define the required conditions and the control method. The selected thermostat must match the switched circuit, not just the required temperature range. The category includes, among others, PTM110, PTM111, PTM122 and PTVT. Verify the contact function, power supply and load capacity for the exact model; do not merge different codes into one general characteristic.
The HGL046 on offer is labelled Winston/OEM in the e-shop. The similarity of the code to a product of another brand does not prove identical origin or parameters. When replacing, request documentation of the specific version supplied and the necessary mounting conditions.
For Rittal or EAE luminaires and their accessories, check the power supply, fixing method, switching and the required connecting cable. Position them so that the light helps read the device and terminal markings even with the doors open. The spatial arrangement is related to the choice of control cabinet enclosure.
No. You need to know the intake temperature, power loss, air path and permissible conditions of the individual components.
Not without verifying the contact function and the entire control wiring. Entrust mounting, wiring and checking of protective measures to a qualified person.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.