Control Cabinet Cooling, Heating and Lighting

Control cabinet cooling, heating and lighting – filter fans, heaters, thermostats and lights. Choose by the cabinet heat balance, dimensions and supply.

Filtry
Znaleziono 22 produktów
NASZA PORADA DOSTĘPNY

PFI1000FILTER, PLASTIM, replacement filter mat

Nr kat.: PFI1000FILTER

PFI1000FILTER, PLASTIM, replacement filter mat

Dostępny 1 ks
1,07 €
bez VAT · 1,29 € z VAT
NASZA PORADA DOSTĘPNY

PFI2500FILTER, PLASTIM, replacement filter mat

Nr kat.: PFI2500FILTER

PFI2500FILTER, PLASTIM, replacement filter mat

Dostępny 1 ks
1,64 €
bez VAT · 1,98 € z VAT
−3 % NASZA PORADA DOSTĘPNY

Z9/03.210/21-Fe, Lidokov, lockable control cabinet door lock with key

Nr kat.: Z9/ 03.210/21- Fe

Lidokov lockable lock for closing the door of an electrical control cabinet. It is supplied with a key and allows access to the internal electrical equipment to be restricted.

Dostępny 5 i więcej szt.
5,57 € 5,74 €
bez VAT · 6,74 € z VAT
NASZA PORADA DOSTĘPNY

PTM110, EMAS, mechanical control cabinet thermostat for heating, NC contact

Nr kat.: PTM110

PTM110, EMAS, mechanical control cabinet thermostat for heating, NC contact. Mechanical thermostat for switching control cabinet heating according to the set temperature.

Dostępny 5 i więcej szt.
5,85 €
bez VAT · 7,08 € z VAT
NASZA PORADA DOSTĘPNY

PFI1000, PLASTIM, filter grille for control cabinets, 120×120×20.5mm, IP54, RAL7035

Nr kat.: PFI1000

PFI1000, PLASTIM, filter grille for control cabinets, 120×120×20.5mm, IP54, RAL7035. PLASTIM filter grille PFI1000 for air inlet or outlet in a control cabinet; a hole of 92×92mm. is required for…

Dostępny 5 i więcej szt.
6,15 €
bez VAT · 7,44 € z VAT
NASZA PORADA DOSTĘPNY

PFI1500, PLASTIM, filter grille, 160×160mm

Nr kat.: PFI1500

PFI1500, PLASTIM, filter grille, 160×160mm

Dostępny 2 ks
7,79 €
bez VAT · 9,43 € z VAT
NASZA PORADA DOSTĘPNY

PFI2500, PLASTIM, filter grille for control cabinets, 260×260×31mm, IP54, RAL7035

Nr kat.: PFI2500

PFI2500, PLASTIM, filter grille for control cabinets, 260×260×31mm, IP54, RAL7035. PLASTIM filter grille PFI2500 for air inlet or outlet in a control cabinet; a hole of 223×223mm. is required for…

Dostępny 3 ks
19,27 €
bez VAT · 23,32 € z VAT
NASZA PORADA DOSTĘPNY

PTF1000, PLASTIM, control cabinet filter fan, 30m³/h, 230VAC, IP54, RAL7035

Nr kat.: PTF1000

PTF1000, PLASTIM: control cabinet filter fan 230VAC with an airflow of 30m³/h and a power consumption of 14W, protection rating IP54.

Dostępny 5 i więcej szt.
20,55 €
bez VAT · 24,86 € z VAT
−3 % NASZA PORADA DOSTĘPNY

EGKL24V-50, EAE, LED control cabinet lighting 24VDC, length 500mm

Nr kat.: EGKL24V-50

The EAE EGKL24V-50 luminaire provides lighting for the interior of an electrical control cabinet. The version is designed for a 24VDC supply and has a length of 500mm.

Dostępny 5 i więcej szt.
22,42 € 23,11 €
bez VAT · 27,13 € z VAT
−5 % NASZA PORADA DOSTĘPNY

PTF1500, PLASTIM, filter fan for control cabinet, 100m³/h, 230VAC, IP54

Nr kat.: PTF1500

PTF1500, PLASTIM, filter fan for control cabinet, 100m³/h, 230VAC, IP54. The PLASTIM filter fan PTF1500 supports air exchange in a control cabinet with a filtered inlet.

Dostępny 5 i więcej szt.
26,88 € 28,30 €
bez VAT · 32,53 € z VAT
−30 % NASZA PORADA DOSTĘPNY

HGL046, TECHNOLINE, fan heater for control cabinet, 230VAC, 400W, IP20

Nr kat.: HGL046

HGL046, TECHNOLINE, fan heater for heating control cabinets, supply 230VAC, power 400W, protection rating IP20.

Dostępny 5 i więcej szt.
53,43 € 76,32 €
bez VAT · 64,66 € z VAT
NASZA PORADA DOSTĘPNY

PTF2500, PLASTIM, filter fan, 115m³/h, 260×260mm, 230VAC

Nr kat.: PTF2500

PTF2500, PLASTIM, filter fan, 115m³/h, 260×260mm, 230VAC

Dostępny 5 i więcej szt.
55,20 €
bez VAT · 66,79 € z VAT
−5 % NASZA PORADA DOSTĘPNY

PTF4500, PLASTIM, control cabinet filter fan, 650m³/h, 230VAC, IP54, 260×260×111mm

Nr kat.: PTF4500

PTF4500, PLASTIM: control cabinet filter fan 230VAC, airflow with filter 650m³/h (without filter 900m³/h), IP54, 260×260×111mm.

Dostępny 1 ks
141,11 € 148,53 €
bez VAT · 170,74 € z VAT
NASZA PORADA

PFI1500FILTER, PLASTIM, replacement filter mat

Nr kat.: PFI1500FILTER

PFI1500FILTER, PLASTIM, replacement filter mat

Na zapytanie
1,68 €
bez VAT · 2,03 € z VAT

2500210, Rittal, system LED luminaire for control cabinet, 900lm, 11W, Schuko, IP20

Nr kat.: 2500210

2500210, Rittal, system LED luminaire for control cabinet, 900lm, 11W, Schuko, IP20. Rittal SZ 2500210 is a system LED light for control cabinets with an integrated Schuko socket.

Na zapytanie
131,33 €
bez VAT · 158,91 € z VAT

Ceny zawierają opłatę recyklingową.

Cooling, heating and lighting of control cabinets

Choose control cabinet accessories according to three separate needs: dissipating heat losses, protection against adverse temperature and humidity conditions, and visibility during maintenance. A fan, a heater and a luminaire are not interchangeable components. Add the enclosure environment, the operating mode of the devices and the power supply available for auxiliary circuits to the brief.

Fan, filter and filter mat

The range includes Plastim PTF, PFI and separate replacement filters. Plastim catalogue 2020, page 29, distinguishes the passive PFI1000 from the fan models PTF1000 and PTF1000T; the last two versions also differ in connection method. This is period documentation for distinguishing the parts, not a guarantee of the identical revision of the current delivery.

If you are ordering replacement filter material, verify the size and suitability for the existing frame. The mat alone does not replace a complete fan. For a fan, compare the power supply, mounting cut-out, airflow direction and the conditions of the stated airflow. Do not use the figure without knowing the filtration arrangement as a certain flow through the finished control cabinet.

When ventilation helps

STEGO describes filtered ventilation as supplying cooler ambient air and removing heated air from the enclosure. This implies an important limit: ventilation alone cannot achieve a temperature below the temperature of the intake air. For the design, the highest temperature at the intake point is therefore important, not just the usual room temperature.

The arrangement of components should allow air to pass through the necessary places. A design in which the flow bypasses only part of the assembly may not solve local overheating. Take into account access to the filter for cleaning and replacement. Set the maintenance interval according to the actual contamination and operation, not as a universal number for all installations.

Author's example of a heat balance

Consider ideal removal of 100 W of heat by an airflow of 60 m³/h. For the chosen density of 1.2 kg/m³ and specific heat capacity of 1 000 J/(kg·K), the mass flow is 0.02 kg/s. From the equation P = ṁ · c · ΔT, the temperature rise of the flowing air is approximately 5 K. A difference of 5 K corresponds to a difference of 5 °C, not to the absolute temperature inside the enclosure.

This is a simplified author's example, not the sizing of a specific PTF. It does not include pressure losses, filter contamination, local hot spots or heat exchange through the walls. The actual design must work with the data of the assembly and the manufacturer. The calculated flow does not verify the protection rating or the suitability of the ambient air supply.

Heating and temperature control

For a heating element, first define the required conditions and the control method. The selected thermostat must match the switched circuit, not just the required temperature range. The category includes, among others, PTM110, PTM111, PTM122 and PTVT. Verify the contact function, power supply and load capacity for the exact model; do not merge different codes into one general characteristic.

The HGL046 on offer is labelled Winston/OEM in the e-shop. The similarity of the code to a product of another brand does not prove identical origin or parameters. When replacing, request documentation of the specific version supplied and the necessary mounting conditions.

Lighting for maintenance

For Rittal or EAE luminaires and their accessories, check the power supply, fixing method, switching and the required connecting cable. Position them so that the light helps read the device and terminal markings even with the doors open. The spatial arrangement is related to the choice of control cabinet enclosure.

FAQ

Will the strongest fan solve every overheating problem?

No. You need to know the intake temperature, power loss, air path and permissible conditions of the individual components.

Can I swap a heating and a cooling thermostat?

Not without verifying the contact function and the entire control wiring. Entrust mounting, wiring and checking of protective measures to a qualified person.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.