On / Off Safety switches 90 °

EMAS ON/OFF 90° cam switches in safety design with red-yellow handle, lockable. Choose by current and number of poles.

Filtry
Znaleziono 36 produktów
NASZA PORADA

PSA050AK141E, EMAS, safety cam switch 0-1, 1pole, 50A, 90 °, IP54

Nr kat.: PSA050AK141E

Single-pole safety cam switch EMAS PSA050AK141E, 50A, position 0-1, turn 90 °, IP54, front frame 64 × 64mm.

Na zapytanie
25,41 €
bez VAT · 30,74 € z VAT
NASZA PORADA

PSA050AK241E, EMAS, safety cam switch 0-1, 2-pole, 50A, 90 °, IP54

Nr kat.: PSA050AK241E

Two-pole EMAS safety cam switch PSA050AK241E for two switched poles, 50A, position 0-1, 90 °, IP54, front frame 64 × 64mm.

Na zapytanie
26,09 €
bez VAT · 31,56 € z VAT
NASZA PORADA

PSA063AK141E, EMAS, safety cam switch 0-1, 1pole, 63A, 90 °, IP54

Nr kat.: PSA063AK141E

EMAS single-pole safety cam switch PSA063AK141E, 63A, position 0-1, 90 ° rotation, IP54, front frame 64 × 64mm.

Na zapytanie
26,45 €
bez VAT · 32,00 € z VAT
NASZA PORADA

PSA080AK141E, EMAS, safety cam switch 0-1, 1pole, 80A, 90 °, IP54

Nr kat.: PSA080AK141E

Single-pole safety cam switch EMAS PSA080AK141E, 80A, position 0-1, turn 90 °, IP54, front frame 85 × 85mm.

Na zapytanie
27,22 €
bez VAT · 32,94 € z VAT
NASZA PORADA

PSA063AK241E, EMAS, safety cam switch 0-1, 2pole, 63A, 90 °, IP54

Nr kat.: PSA063AK241E

Two-pole EMAS safety cam switch PSA063AK241E for two switched poles, 63A, position 0-1, 90 °, IP54, front frame 64 × 64mm.

Na zapytanie
27,98 €
bez VAT · 33,86 € z VAT
NASZA PORADA

PSA080AK241E, EMAS, safety cam switch 0-1, 2pole, 80A, 90 °, IP54

Nr kat.: PSA080AK241E

Two-pole EMAS safety cam switch PSA080AK241E for two switched poles, 80A, position 0-1, 90 °, IP54, front frame 85 × 85mm.

Na zapytanie
32,50 €
bez VAT · 39,33 € z VAT
NASZA PORADA

PSA040AK941E, EMAS, safety cam switch 0-1, 3P + N, 40A, 90 °, IP54

Nr kat.: PSA040AK941E

The safety main cam switch EMAS PSA040AK941E for three phases and neutral wire (3P + N), 40A, switch 0-1 by 90 °, IP54, forehead 64 × 64mm.

Na zapytanie
36,86 €
bez VAT · 44,60 € z VAT
NASZA PORADA

PSA050AK941E, EMAS, safety cam switch 0-1, 3P + N, 50A, 90 °, IP54

Nr kat.: PSA050AK941E

The safety main cam switch EMAS PSA050AK941E for three phases and neutral wire (3P + N), 50A, switch 0-1 by 90 °, IP54, forehead 64 × 64mm.

Na zapytanie
49,63 €
bez VAT · 60,06 € z VAT
NASZA PORADA

PSA080AK341E, EMAS, safety cam switch 0-1, 3-pole, 80A, 90 °, IP54

Nr kat.: PSA080AK341E

Three-pole safety cam switch EMAS PSA080AK341E, 80A, control 0-1, 90 °, IP54, front frame 85 × 85mm. For three separately switched poles.

Na zapytanie
50,50 €
bez VAT · 61,11 € z VAT
NASZA PORADA

PSA063AK941E, EMAS, safety cam switch 0-1, 3P + N, 63A, 90 °, IP54

Nr kat.: PSA063AK941E

EMAS safety main cam switch PSA063AK941E for three phases and neutral wire (3P + N), 63A, switch 0-1 by 90 °, IP54, forehead 64 × 64mm.

Na zapytanie
52,43 €
bez VAT · 63,44 € z VAT
NASZA PORADA

PSA080AK941E, EMAS, safety cam switch 0-1, 3P + N, 80A, 90 °, IP54

Nr kat.: PSA080AK941E

The safety main cam switch EMAS PSA080AK941E for three phases and neutral wire (3P + N), 80A, switch 0-1 by 90 °, IP54, forehead 85 × 85mm.

Na zapytanie
55,51 €
bez VAT · 67,16 € z VAT

Ceny zawierają opłatę recyklingową.

On / Off Safety switches 90 °

This branch combines devices On/Off with a 90° rotation. When selecting, separate the operating control, the maintenance disconnection function, and the functional safety control. The term 'Safety' alone does not prove PL or SIL and does not confirm the specific insulation or disconnection property of each product. Each such request must be based on documentation of the exact implementation.

What is supported by a specific product

The offer includes EMAS PSA010AK141E, PSA016AK341E and PSA016AK941E. EMAS in PSA016AK341E presents On- Off for three phases, position 0-1, angle 90 °, forehead 48 × 48 mm and Ie 16 A in AC21A. Three electric paths and two control positions are not a contradiction: they are two different properties.

The specific designation is also important for any neutral pole, mechanical implementation, and method of installation. The presence of an additional pole does not say anything about the order of its operation. From the handle, it cannot be inferred whether it is lockable, positive disengagement, or a specific function for insulation. Required properties should be determined for the selected code, not just for the related series.

Safety functions belong to the whole design

Pilz explains the functional safety assessment At the level of specific safety functions and related control parts. The required level is based on risk assessment. Using a component with a specific name or color is not a substitute for design and verification of the relevant function.

Operational shutdown can only cancel the machine request. Service disconnection addresses other issues, such as possible additional power, residual energy, or unwanted reactivation. Emergency stop is another separate request. These tasks cannot be combined with a single word 'shutdown' without specifying what the assembly actually ensures.

Model example of service workstation entry

Consider a specific example: the device has a main electrical drive, a separately powered control interface, and pneumatic movement. The customer requests that position 0 stops normal operation. This does not imply that the interface is disconnected or that the compressed air energy is removed. A three-pole implementation cannot answer questions outside the paths it actually controls.

In the specification, separate three verifiable requests: canceling the operational command, determining the method of disconnecting electrical sources, and measures against unexpected movement. For each, it must be clear which part of the device fulfills it and how the function is verified. The example is not a valid safety concept or service manual.

Load, installation and verification

When selecting electrically, do not classify AC21A as a universal motor category. Amps on the label cannot directly infer the allowed movement power. For the project, essential conditions for rotation, voltage, load, and its behavior during state change. Similarly, a plug switch does not automatically provide overcurrent or short-circuit protection.

The installation shall respect the manufacturer's design and the corresponding accessoriesThe compliance of the label, handle, and actual contact states is verified; electrical testing is not part of the appearance after installation. Network connections and safety measures should be handled by a professional.

Frequently asked questions

Does 90 ° increase safety against 60 °?

The angle itself does not allow such a conclusion. Compare documented functions and parameters, not just a mechanical path. Alternative controls represent On / Off Switches 60 °.

Where to begin when the request is unclear?

First, describe the expected state of the device and its energy source. Vacuum cleaners.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.