Pressure sensor, thread G1/4", for pressure 100 bar, output 4-20mA, PB1111
Pressure sensor, thread G1/4", for pressure 100 bar, output 4-20mA, PB1111
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
EMA pressure sensors with analogue output for liquids and gases. Choose by pressure range, medium, process connection and output.
Pressure sensor, thread G1/4", for pressure 100 bar, output 4-20mA, PB1111
Pressure sensor, thread G1/4", for pressure 200 bar, output 4-20mA, PB1113
Pressure sensor, thread G1/4", for pressure 250 bar, output 4-20mA, PB1120
Pressure sensor, thread G1/4", for pressure 400 bar, output 4-20mA, PB1115
Pressure sensor, thread G1/2", for pressure 100 bar, output 0-10V, 2PB1112
Pressure sensor, thread G1/2", for pressure 200 bar, output 0-10V, 2PB1114
Pressure sensor, thread G1/2", for pressure 250 bar, output 0-10V, 2PB1120
Pressure sensor, thread G1/2", for pressure 400 bar, output 0-10V, 2PB1116
Pressure sensor, thread G1/2", for pressure 100 bar, output 4-20mA, 2PB1111
Pressure sensor, thread G1/2", for pressure 200 bar, output 4-20mA, 2PB1113
Pressure sensor, thread G1/2", for pressure 250 bar, output 4-20mA, 2PB1120
Pressure sensor, thread G1/2", for pressure 400 bar, output 4-20mA, 2PB1115
Pressure sensor, thread G1/4", for pressure 600 bar, output 0-10V, PB1118
Pressure sensor, thread G1/4", for pressure 600 bar, output 4-20mA, PB1117
Pressure sensor, thread G1/2", for pressure 600 bar, output 0-10V, 2PB1118
Pressure sensor, thread G1/2", for pressure 600 bar, output 4-20mA, 2PB1117
Ceny zawierają opłatę recyklingową.
Choose an EMA pressure sensor as part of a specific measuring point. The normal pressure, short-term peaks, properties of the medium and the signal required by the control input are important. When replacing an older device, therefore, do not rely on an identical housing appearance. Record the complete code, connection designation and evaluation method; it is precisely this combination that determines what the new device must meet.
The range here includes PB and 2PB analogue transmitters and accessories US0004 and US0005. To select a specific transmitter, continue to Simple pressure sensors. Mechanical connections are addressed by pressure Accessories. Split the order into the measuring device, mechanical parts and electrical connection so that a verified counterpart is not missing during mounting.
WIKA distinguishes between measuring range, overload and burst pressure. The burst limit is not a permissible working pressure. In the specification, therefore, also state events during valve closure, pump start-up and depressurisation, not just the value monitored during steady operation. The specific limit for EMA must be determined by the corresponding product sheet.
An excessively wide range can be a disadvantage if the significant deviation is specified as a percentage of its full-scale value. Conversely, an excessively narrow range may not cover actual operation. Therefore base the decision on the required resolution of changes and documented load limits. The error in bar cannot be calculated from the expression "accuracy in percent" without stating the basis.
Let us compare two model devices with ranges of 0 to 10 bar and 0 to 100 bar. For the example, assign both a deviation of ±0.5 % of full scale. The first corresponds to ±0.05 bar, the second to ±0.50 bar. At a measured pressure of 2 bar, this is 2.5 % and 25 % of the value currently measured, respectively.
These deviations are not parameters of EMA products. The calculation only shows the significance of the selected range. The actual uncertainty may include other influences, and when comparing catalogues it is necessary to distinguish linearity, repeatability, temperature influence and the method of determining the resulting deviation.
Check all wetted materials, not just the visible metal of the connection. WIKA also includes seals among wetted parts; their suitability may be decisive for a specific liquid. The resistance of the housing to the environment is assessed separately from the chemical and thermal suitability of the process connection.
Before mounting, record the tapping location, device orientation and the required service space. Make the connection after depressurising and securing the process. After installation, verify tightness and compare the reading with a reference in several operating states. If short peaks appear, first determine their origin; smoothing the display alone does not prove that the mechanical stress on the measuring point has disappeared.
For maintenance, keep the set input range, units and the acceptance report. Future replacement can then be based on documented requirements, not on memory of the last display value.
No. Compare the exact range, pressure reference system, output, connection and operating conditions.
A mechanical adapter alone does not convert the range. It enables a specific connection, whose suitability and limit conditions must be verified separately.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.