IFM Flow Sensors

ifm SI series flow sensors for monitoring the flow of liquids and gases and SM flow meters for measuring flow and consumption. Choose by medium, range and output.

Filtry
Znaleziono 10 produktów
NASZA PORADA

Flow sensor SI5004 IFM, SID10ADB100G/US-100

Nr kat.: SI5004

electrical design DC PNP, supply voltage 19 – 30 VDC, output function analogue 4 - 20mA, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, protection IP67, pressure rating…

Na zapytanie
309,17 €
bez VAT · 374,09 € z VAT
NASZA PORADA

Flow sensor SI5000 IFM, SID10ABBFPKG/US-100

Nr kat.: SI5000

electrical design DC PNP, supply voltage 19 – 30 VDC, output function NO/NC, programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, measuring range for gases 200…

Na zapytanie
310,73 €
bez VAT · 375,99 € z VAT
NASZA PORADA

Flow sensor SI5007 IFM, SID10ADBFPKG/US-100

Nr kat.: SI5007

electrical design DC PNP, supply voltage 19 – 30 VDC, 2 output functions: 1x NO/NC programmable 1x temperature monitoring, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s…

Na zapytanie
322,21 €
bez VAT · 389,87 € z VAT
NASZA PORADA

Flow sensor SI5002 IFM, SID10ADBFPKG/US-100

Nr kat.: SI5002

electrical design DC PNP, supply voltage 19 – 30 VDC, output function 2x NO/NC programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s measuring range for gases 200…

Na zapytanie
327,13 €
bez VAT · 395,82 € z VAT
NASZA PORADA

Flow sensor SM6050 IFM, SMR12GGX1OKG/US-100

Nr kat.: SM6050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...25 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…

Na zapytanie
436,99 €
bez VAT · 528,76 € z VAT
NASZA PORADA

Flow sensor SM7050 IFM, SMR34GGX1OKG/US100

Nr kat.: SM7050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...50 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…

Na zapytanie
525,73 €
bez VAT · 636,14 € z VAT
NASZA PORADA

Flow sensor SM8050 IFM, SMR11GGX1OKG/US100

Nr kat.: SM8050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...100 l/min, medium temperature -10°C .. +70°C, protection IP67 - pressure rating 16bar - process…

Na zapytanie
629,16 €
bez VAT · 761,28 € z VAT
NASZA PORADA

SM6000, flow sensor, SMR12GGXFRKG/US-100, IFM

Nr kat.: SM6000

SM6000, flow sensor; voltage: 19-30VDC; output: PNP/NPN; SMR12GGXFRKG/US-100, IFM

Na zapytanie
672,16 €
bez VAT · 813,31 € z VAT
NASZA PORADA

Flow sensor SM7000 IFM, SMR34GGXFRKG/US-100

Nr kat.: SM7000

electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…

Na zapytanie
673,49 €
bez VAT · 814,92 € z VAT
NASZA PORADA

Flow sensor SM8000 IFM, SMR11GGXFRKG/US-100

Nr kat.: SM8000

electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…

Na zapytanie
777,04 €
bez VAT · 940,21 € z VAT

Ceny zawierają opłatę recyklingową.

IFM flow sensors

Should the equipment only confirm the flow of coolant, or do you need to record its flow rate and the quantity drawn? The difference affects the choice of sensor and the method of evaluation. A limit signal can serve well as an operating condition, but on its own it does not say how many litres have passed through the pipe. Therefore formulate the specification as a specific requirement for information, for example a drop in flow, instantaneous flow or dose total.

The SI and SM series address different tasks

The range here includes, for example, SI5000, SI5004, SI5007, SM6000 and SM6050. IFM, for the SI calorimetric principle explains the sensing of heat removal by the flowing medium. It is a response at the location of the measuring tip. Local velocity cannot simply be declared the mean velocity of the entire pipe without knowing the velocity profile.

Product sheet SM6000 describes magnetic-inductive measurement of conductive liquids, quantity totalising and temperature monitoring. These are different operating information whose transfer to the control system depends on the configuration. Do not transfer the properties of SM6000 to other codes of the SM series without checking.

Selection starts with the operating scenario

Describe the medium including its changes during operation, the normal and lowest flow, pressure and temperature. Decide whether the operators need local indication and whether the control system expects a contact, an analogue value or pulses. Then compare precisely these requirements with each candidate's datasheet. An identical connector does not yet mean an identical signal on the individual pins.

To check cooling, determine in advance a test that represents a real fault: for example, closing a branch or stopping the pump in a controlled test. Merely changing the sensor setting does not verify that its location will capture the problem in the required part of the circuit. With several parallel branches, it must be clear which branch the measurement actually represents.

Author's example: flow and dose

At a model constant flow of 12 l/min, a volume of 12 × 45 / 60 = 9 litres passes in 45 seconds. For a separate example, assume pulse evaluation set to 0.10 litre per pulse. Nine litres correspond to 90 pulses. When the sensor setting is changed to 0.20 litre per pulse, the same nine-litre dose produces only 45 pulses. An unchanged program with a conversion of 0.10 litre per pulse then evaluates only 4.5 litres.

The time, flow and pulse value are chosen by the author, not the default settings of the products listed. With variable flow, the volume is obtained by summing the contributions over time. Moreover, the accuracy of the entire dose cannot be derived solely from the number of decimal places on the display.

Mounting and operational check

Verify the required orientation, immersion of the tip or filling of the measuring tube and the lengths of the calming sections according to the manual of the selected model. Do not invent one common distance from a bend for all series. Ensure the possibility of checking deposits and service disconnection. After start-up, record the steady state, zero flow and the response during start-up; only adjust the limits and control timing according to the results.

A wider range is contained in Flow sensors. For separate temperature monitoring of the cooling circuit, continue to Temperature sensors.

FAQ

Does a lit flow indicator mean correct cooling?

It only confirms the evaluated state. Adequate cooling also depends on the liquid temperature and the requirements of the cooled equipment.

Can a new model be connected without changing the program?

First compare outputs, scale, units and fault states. Verify compatibility throughout the chain from the sensor to the display.