EX302015, EAE, stainless steel wall-mounted distribution board, 300×200×150mm (H×W×D), with mounting plate
EX302015, EAE, stainless steel wall-mounted distribution board, 300×200×150mm (H×W×D), with mounting plate
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Control cabinets and enclosures – sheet steel, stainless steel, plastic, free-standing and surface-mounted distribution boards – plus equipment for cooling, heating and lighting. Choose by size, material, protection rating and mounting equipment.
EX302015, EAE, stainless steel wall-mounted distribution board, 300×200×150mm (H×W×D), with mounting plate
EM608030, EAE, sheet steel control cabinet enclosure with mounting plate, 600×800×300mm, RAL7035, IP66. EM series wall-mounted enclosure designed for fitting electrical devices.
EO806025, EAE, sheet steel control cabinet enclosure with mounting plate, 800×600×250mm, RAL7035, IP66. EO series wall-mounted enclosure designed for fitting electrical devices.
XM404020, EAE, stainless steel control cabinet enclosure, 400×400×200mm, IP66. XM series stainless steel monobloc control cabinet enclosure with dimensions 400×400×200mm for applications requiring…
Stainless steel control cabinet enclosure EAE, EX series, with dimensions 400×300×200mm. The version is intended for wall-mounted fitting of devices and conductor routes in the control cabinet.
XM505020, EAE: stainless steel enclosure, outer dimensions 500×500×200mm (H×W×D); for fitting electrical components.
Sheet steel control cabinet enclosure EAE, EO series, with dimensions 900×600×150mm. The version is intended for space-saving wall mounting of electrical equipment. Surface colour: RAL7035.
EO906020, EAE: sheet steel control cabinet enclosure, outer dimensions 900×600×200mm (H×W×D), RAL7035, with mounting plate, protection rating IP66.
EO906030, EAE. control cabinet enclosure. 900×600×300mm (H×W×D). IP66. pallet shipping 1 000 CZK.
EO1007040, EAE: sheet steel control cabinet enclosure, outer dimensions 1000×700×400mm (H×W×D), RAL7035, with mounting plate, protection rating IP66.
EO1006020, EAE. control cabinet enclosure. 1000×600×200mm (H×W×D). IP66. pallet shipping 1 000 CZK.
EO1006025, EAE: sheet steel control cabinet enclosure, outer dimensions 1000×600×250mm (H×W×D), RAL7035, with mounting plate, protection rating IP66.
EO1006030, EAE, sheet steel control cabinet enclosure with mounting plate, 1000×600×300mm, RAL7035, IP66. EO series wall-mounted enclosure designed for fitting electrical devices.
Sheet steel control cabinet enclosure EAE, EO series, with dimensions 1200×600×300mm. The version is intended for larger wall-mounted assemblies of control, protective and installation elements…
EO1208020, EAE. control cabinet enclosure. 1200×800×200mm (H×W×D). IP66. pallet shipping 1 000 CZK.
Sheet steel control cabinet enclosure EAE, EO series, with dimensions 1000×800×400mm. The version is intended for larger wall-mounted assemblies of control, protective and installation elements…
EO1007020, EAE, sheet steel control cabinet enclosure with mounting plate, 1000×700×200mm, RAL7035, IP66. EO series wall-mounted enclosure designed for fitting electrical devices.
EO1007030, EAE: sheet steel control cabinet enclosure, outer dimensions 1000×700×300mm (H×W×D), RAL7035, with mounting plate, protection rating IP66.
Sheet steel control cabinet enclosure EAE, EO series, with dimensions 1200×800×300mm. The version is intended for larger wall-mounted assemblies of control, protective and installation elements…
EO1208040, EAE. control cabinet enclosure. 1200×800×400mm (H×W×D). IP66. pallet shipping 1 000 CZK.
Sheet steel control cabinet enclosure EAE, ED series, with dimensions 1600×600×600mm. The version is intended for free-standing control cabinet assemblies and their internal electrical equipment…
Sheet steel control cabinet enclosure EAE, ES series, with dimensions 2000×600×400mm. The version is intended for free-standing control cabinet assemblies and their internal electrical equipment…
Ceny zawierają opłatę recyklingową.
A control cabinet enclosure forms the mechanical basis for installing control and electrical devices. The selection does not start with the outer dimensions alone: you need to know the environment, the list of components, how the cables are brought in and the expected service interventions. An empty enclosure is not a finished control cabinet. The properties of the resulting assembly must be assessed after fitting the devices and making the mounting holes.
Draw the components in the drawing, including terminals, connectors and the space needed for removal. Separately allow for cable trunking, a reserve for bending conductors and the wiring to door-mounted devices. Check the depth of the assembly from the mounting surface to the closed door; the available space cannot be derived directly from the outer depth of the enclosure without a design drawing.
The manufacturer card Rittal AX 1045000 states the dimensions of the enclosure and the mounting plate separately. This is an useful model for comparing offers: require both figures, not just one number from the commercial name. An exact numerical comparison of this model can be found in the guide to sheet steel enclosures.
Divide the description of the installation site into temperature, humidity, dust, exposure to liquids, chemicals and mechanical stress. Do not reduce these influences to a single general requirement “outdoor version”. Also prepare the fixing method and accessibility once the machine is finished. The doors must be able to open in the real space, not just on the floor plan of an empty hall.
Supplement the cable list with their outer diameters and directions of approach. Only on this basis are glands, fittings and the required entry area selected. An extra hole is not a mounting reserve if it remains unsealed. The design of the entries and the seals used must meet the requirements of the enclosure and accessory manufacturers.
On a model mounting surface 400 mm wide, consider devices with a total width of 250 mm and two trunkings of 40 mm each. 70 mm remains for other needs. This result is not automatically a sufficient reserve: it does not yet address the prescribed clearances, terminals, wiring between rows or depth. The dimensions are chosen only to illustrate the procedure; they are not parameters of the enclosure offered.
Record the power losses of the components and their permitted ambient conditions. Assess the layout of the assembly and the thermal design together, especially for power supplies, power switches and drives. The number of fitted devices is not enough for selecting accessories. The documentation should capture the actual load, operating mode and the highest expected temperature at the installation site.
No. Also compare the material, mechanical layout, mounting options and specific conditions of use. The protection rating alone does not describe these properties.
For a replacement, also attach a drawing of the fitting, entries and fixing. Verify the scope of delivery of the plate, lock and other parts. The design and verification of the electrical assembly belong to a qualified person.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.