Energy-saving ceramic infrared emitters Elstein - HTS
With the HTS series, it pays to start with the operating cycle: how long the line produces, how many times it starts and what happens while waiting for the next batch. The term energy-saving only makes sense in relation to a specific process and the same production quality. For the decision, prepare an initial energy measurement and an unambiguous boundary of the equipment being compared.
Design and version
The HTS data sheet describes hollow ceramics with internal thermal insulation. HTS has a face of 122 × 122 mm, HTS/1 245 × 60 mm, HTS/2 122 × 60 mm and HTS/4 60 × 60 mm. T-HTS versions have a built-in type K thermocouple. The stated face dimensions do not replace the mounting drawing.
When selecting, compile an overview of the positions to be fitted. For each position, record the required size, rated power, voltage and measurement requirement. The similarity of names alone is not enough to approve a replacement. In the order, distinguish the specific body and the function it will perform in the whole control zone.
What the controller actually controls
The explanation of ELSTEIN power control places the built-in thermocouple between the heating conductor and the radiating surface. Its signal therefore describes the emitter, not the product directly. The manufacturer also describes dividing the field into separately controlled zones; control according to the product temperature requires reliable measurement of the material itself.
For your own control brief, determine which sample represents the most critical product. Base acceptance on its result and at the same time keep the trend of the controlled variable. Also record changes in speed, dwell times and fixture changes. Two identical values on the display cannot be used as the only proof of an identical process if other conditions have changed. In a multi-zone assembly, assign each record to a specific zone and its sensed position. During acceptance, also verify the situation where an adjacent zone works according to a different recipe. In the operating procedure, state which setting combinations have actually been tested.
Author's model example: how to evaluate consumption
For illustration, let us choose a fictitious heating with two zones, each with an installed power of 1.2 kW. During the ten-minute monitored part of the cycle, the first zone is switched on for a total of four minutes, the second for six minutes. Neglecting changes in instantaneous power in the model, they consume 1.2 × 4/60 = 0.08 kWh and 1.2 × 6/60 = 0.12 kWh. The sum is 0.20 kWh.
This is not an HTS measurement or a promised saving. In an actual comparison, add start-up, waiting and other loads included within the same measurement boundary. If the model batch produced twenty compliant pieces, the result is 0.010 kWh per compliant piece only for the monitored section. Rejected pieces do not belong in this denominator. The compared variants must meet the same acceptance criteria.
Mounting, signal and finding the cause of a deviation
According to the mounting instructions installation must be carried out by qualified personnel. For third-party controllers and PLCs, the manufacturer requires electrically isolated thermocouple inputs, also from each other. Verify this requirement for the specific input module.
Diagnostic sheet M 1.3 guides the check from the thermocouple type through its wiring to the controller setting. An incorrect signal therefore does not automatically mean a faulty heating element. Electrical tests belong to qualified service; this is not a guide to wiring or testing under voltage.
FAQ
Can the saving be determined from the HTS designation?
For your own line, determine it by comparing the measured energy with the same production result. Include normal starts and downtime, otherwise the conclusion will only apply to the selected section.
What should be compared when switching from FSR?
Prepare verification of the mechanical seating, electrical data, measurement and production result. The original series can be found in the category FSR; the design of the whole assembly is summarised in Ceramic infrared emitters.