6041661, SICK, ultrasonic level sensor UP56-211112, 30–250mm, PNP, 9–30VDC, Connector M12/5
UP56-211112 (6041661), SICK – ultrasonic level sensor, 30–250mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Ultrasonic level sensors measure the distance from the transducer to the surface of the medium without direct contact with the level. This group includes devices explicitly intended by the manufacturer for level measurement in tanks and silos. Always assess suitability for liquids or bulk solids according to the specific medium and version.
UP56-211112 (6041661), SICK – ultrasonic level sensor, 30–250mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211114 (6041664), SICK – ultrasonic level sensor, 30–250mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211115 (6073255), SICK – ultrasonic level sensor, 30–250mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211118 (6041658), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211128 (6048700), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211148 (6048942), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211156 (6050441), SICK – ultrasonic level sensor, 30–250mm, 4–20mA, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-211156S01 (6086572), SICK – ultrasonic level sensor, 30–250mm, 4–20mA, 9–30VDC. Parameters, wiring and manufacturer documentation.
UP56-2111A8 (6054782), SICK – ultrasonic level sensor, 30–250mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212112 (6041662), SICK – ultrasonic level sensor, 85–350mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212114 (6041665), SICK – ultrasonic level sensor, 85–350mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212115 (6073256), SICK – ultrasonic level sensor, 85–350mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212118 (6041659), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212128 (6048701), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212148 (6048943), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-212156 (6049945), SICK – ultrasonic level sensor, 85–350mm, 4–20mA, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-2121A8 (6054783), SICK – ultrasonic level sensor, 85–350mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213112 (6041663), SICK – ultrasonic level sensor, 200–1300mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213114 (6041666), SICK – ultrasonic level sensor, 200–1300mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213115 (6073257), SICK – ultrasonic level sensor, 200–1300mm, IO-Link, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213118 (6041660), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-213128 (6048702), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-2131A8 (6054784), SICK – ultrasonic level sensor, 200–1300mm, PNP, 4–20mA/0–10V, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-214112 (6041695), SICK – ultrasonic level sensor, 350–3400mm, PNP, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
UP56-214114 (6041694), SICK – ultrasonic level sensor, 350–3400mm, NPN, 9–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.
Ceny zawierają opłatę recyklingową.
Ultrasonic level sensors measure the distance from the transducer to the surface of the medium without direct contact with the level. This group includes devices explicitly intended by the manufacturer for level measurement in tanks and silos. Always assess suitability for liquids or bulk solids according to the specific medium and version.
The BUS M30E2 series is explicitly intended by the manufacturer for non-contact level measurement in tanks. Assess the G 1 process connection and the design of the active face together with the medium, pressure and required sealing method. The maximum range may not be identical to the recommended working range; the datasheet of the specific variant is decisive.
View BALLUFF BUS005U · Use of the M30E2 series for level according to the manufacturer.
A level meter evaluates the return of the ultrasonic echo. The level height is determined from the measured distance and the specified geometry. For continuous measurement, verify the corresponding analogue or digital output; a switching output signals that a set limit has been reached. Conversion to volume requires knowledge of the vessel shape.
With an empty tank, the surface must still be within range, and when full it must remain outside the blind zone. Allow a reserve for waves. Choose the sensor position with regard to walls, stiffeners, agitators and the filling stream, which can create unwanted reflections or obstruct the measuring path.
Foam can attenuate the ultrasonic signal; a changing environment affects sound propagation. Therefore also test filling, emptying and agitation. For bulk solids, take into account the uneven surface and the pouring cone. The degree of protection of the housing alone does not confirm chemical resistance or usability in a pressure vessel.
In some applications yes, if it corresponds to the documentation and operating conditions. However, the mere ability to sense a liquid surface does not make an ordinary sensor a process level meter. Assess the design and the manufacturer's explicit intended use together.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: VEGA ultrasonic level meter technical documentation · VEGA documentation on ultrasonic level measurement.
The level height is the difference between the known distance of the face from the reference bottom and the currently measured distance to the surface. Conversion to volume requires the vessel geometry; the highest level must remain outside the blind zone.
No. For example, BUS005U has two PNP switching outputs for limit states. For continuous measurement, compare the analogue variants BUS005W, BUS005Y, BUS0085 or BUS0086 and their specific range.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.