U500.PA0-GP1B.72CU, BAUMER, ultrasonic proximity sensor, 100–1000mm, push-pull, PUR cable 2m, 4×0.25,, IP67
U500.PA0-GP1B.72CU – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output push-pull. Cable PUR 2m, 4×0.25,. IP67.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
U500.PA0-GP1B.72CU – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output push-pull. Cable PUR 2m, 4×0.25,. IP67.
U500.RA0-GP1B.72CU – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output push-pull. Cable PUR 2m, 4×0.25,. IP67.
Ultrasonic sensor, through-beam 20x30x12, DC, PNP, NO, Sn:300.2m cable
Ultrasonic sensor, through-beam 24x50x12, DC, PNP, NO, Sn:1100.2m cable
BUS006J Balluff: ultrasonic sensor Q62K1, range 350–5 000 mm, 0–10V / 4–20mA. Overview of parameters, connection and suitable use at TECHNOLINE.
UNDK 20N7903/S35A – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally closed (NC). Connector M8. IP67.
UNDK 20N7912/S35A – ultrasonic proximity sensor BAUMER. Range 40–400mm. Output NPN, normally closed (NC). Connector M8. IP67.
URDK 20N6903/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output NPN, normally open (NO). Connector M8. IP67.
URDK 20N7903/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output NPN, normally closed (NC). Connector M8. IP67.
BUS006K Balluff: ultrasonic sensor Q62K1, range 600–8 000 mm, 0–10V / 4–20mA. Overview of parameters, connection and suitable use at TECHNOLINE.
URCK 09G8914 – ultrasonic retro-reflective sensor BAUMER. Range 0–200mm. Output push-pull. Cable 2m. IP67.
UNDK 20N6903/S35A – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally open (NO). Connector M8. IP67.
UNDK 20N6912/S35A – ultrasonic proximity sensor BAUMER. Range 40–400mm. Output NPN, normally open (NO). Connector M8. IP67.
UNDK 20N6914/S35A – ultrasonic proximity sensor BAUMER. Range 10–200mm. Output NPN, normally open (NO). Connector M8. IP67.
UNDK 20N7914/S35A – ultrasonic proximity sensor BAUMER. Range 10–200mm. Output NPN, normally closed (NC). Connector M8. IP67.
UNDK 20P7803/S35A – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output PNP, normally closed (NC). Connector M8. IP67.
UNDK 20P7912/S35A – ultrasonic proximity sensor BAUMER. Range 40–400mm. Output PNP, normally closed (NC). Connector M8. IP67.
UNDK 20P7914/S35A – ultrasonic proximity sensor BAUMER. Range 10–200mm. Output PNP, normally closed (NC). Connector M8. IP67.
URDK 20N6912/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–400mm. Output NPN, normally open (NO). Connector M8. IP67.
URDK 20N6914/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–200mm. Output NPN, normally open (NO). Connector M8. IP67.
URDK 20N7912/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–400mm. Output NPN, normally closed (NC). Connector M8. IP67.
URDK 20N7914/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–200mm. Output NPN, normally closed (NC). Connector M8. IP67.
URDK 20P7903/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–1000mm. Output PNP, normally closed (NC). Connector M8. IP67.
URDK 20P7912/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–400mm. Output PNP, normally closed (NC). Connector M8. IP67.
URDK 20P7914/S35A – ultrasonic retro-reflective sensor BAUMER. Range 0–200mm. Output PNP, normally closed (NC). Connector M8. IP67.
Ceny zawierają opłatę recyklingową.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
Compare the mounting holes, the position of the active surface and the cable or connector outlet. A low installation height does not mean that any obstacle can be placed in front of the face. Surrounding brackets and walls can reflect sound and affect detection. Also leave access to the setting buttons and indicators.
The design size does not indicate the measuring range. Verify the minimum and maximum working distance, blind zone and detection diagram for a suitable target. The switching version transmits a state; the analogue variant provides a continuous signal. Assess PNP/NPN, current or voltage analogue and communication separately from the NO/NC logic.
BALLUFF BUS006H,, designated BUS Q62K1-PWX-60/600-S92K,, is listed by the manufacturer as a rectangular version with two PNP NO/NC switching outputs and a five-pin M12 connector. This is an example of a design; the same parameters cannot be transferred to the entire Q62 series or to other rectangular sensors.
Carry out a test with the actual material and in all working positions. When several ultrasonic sensors operate together, verify mutual interference. Take the settings and any synchronisation from the manual of the exact order code.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Technical data BALLUFF BUS006H · Mounting ultrasonic sensors – microsonic.
A rectangular or flat housing is suitable where its mounting holes, height or direction of the active surface fit better. Decide according to the drawing and the space for the cable and sound beam.
The housing shape alone does not determine the range. For each variant, compare the working distance, blind zone, response and target size given in the detection diagram.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.