PTE100-40-06-PS60-G1/4, TECHNOLINE, PT100 sensor
PTE100-40-06-PS60-G1/4, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
TECHNOLINE PTE100 temperature probes with Pt100 sensor in various mechanical designs. Choose by probe length and diameter, wiring and cable length.
PTE100-40-06-PS60-G1/4, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.
PTE100-40-4.6-WP, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.
PTE100-30-4.6-WP, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.
Ceny zawierają opłatę recyklingową.
The Pt100 cable probe is part of a measuring chain that continues with the lead, the device input and its settings. Selection therefore does not end with a matching temperature range. You need the correct mechanical design, a suitable measuring point and electrical compatibility. When replacing, prepare the complete code, the dimensions of the original probe and the diagram of the input to which it will be connected.
The range contains PTE100-40-06-PS60-G1/4 and cylindrical PTE100-30-4.6-WP and PTE100-40-4.6-WP. Product sheet PTE100-30-4.6-WP confirms the resistance element Pt100, body length 30 mm and diameter 4.6 mm. PTE100-40-06-PS60-G1/4 uses connection G1/4. Threaded and smooth versions require a different fixing design; they cannot be interchanged just by the name Pt100.
Pt100 denotes a platinum resistance element with a nominal resistance of 100 ohms at 0 °C. The basics are explained by the manufacturer's overview of resistance measurement. However, the designation alone does not determine the accuracy of the entire cable probe, the number of lead wires or the response speed after mounting. These properties must be obtained for the specific version and linked to the capabilities of the input.
Resistance is evaluated using a measuring current. The WIKA handbook describes self-heating of the measuring element by this current. For assessment, request data on the excitation current of the device used and the permitted conditions of the sensor. A lower current alone does not solve all errors; input resolution, cable routing and the actual heat dissipation from the measuring point remain part of the design.
WIKA distinguishes two-, three- and four-wire Pt100 connections. Two-wire measurement includes the lead resistance. Verify the wiring of a specific probe from the documentation, not by estimating from a photograph.
For an educational resistance of 100 ohms and a current of 1 mA, the electrical power is P = I²R = 0.001² × 100 = 0,0001 W, i.e. 0.1 mW. When the current is increased to 2 mA, the power is 0.4 mW. Double the current therefore means four times the contribution of electrical heating.
These are not recommended currents nor data on the temperature error of the PTE100. probes. To convert power into a temperature rise, the thermal resistance of the specific mounting would need to be known. The example serves to understand why the sensor should be connected to the specified measuring input and not to an arbitrary voltage source.
Check the seating of the probe, the position of the measuring end and cable strain relief. For the threaded version, verify the sealing geometry and permitted process conditions; G1/4 alone is not data on pressure resistance. During acceptance, compare the steady value with a reference and monitor the response to a change. Document the test including wiring, ambient temperature and fixing method so that it can be repeated after replacement.
To compare designs, visit Enda temperature sensors and the common overview Temperature sensors.
No. The accuracy class and its conditions must be confirmed by the documentation of the specific probe.
First verify the wiring, permitted lead resistance and input conditions. After extension, check the entire measuring chain again.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.