Profile LED Beacon

Profile LED beacons (light bars) for longitudinal status signalling on the machine. Choose by length, colours, supply and wiring (common anode or cathode).

Filtry
Znaleziono 34 produktów
NASZA PORADA

TELP424O-RGBW- SK, TECHNOLINE, four-colour profile LED signalling beacon 420 mm, color red + green + blue + white, 24 V DC, common cathode, cable 5 m

Nr kat.: TELP424O-RGBW-SK

TELP424O-RGBW-SK TECHNOLINE - four-colour profile LED signalling beacon 420 mm; colours red + green + blue + white; 24 V DC; common cathode. Precise technical specifications, use and selection of…

Na zapytanie
37,26 €
bez VAT · 45,08 € z VAT
NASZA PORADA

TELP624O-RGBW- SK, TECHNOLINE, four-colour profile LED signalling beacon 620 mm, color red + green + blue + white, 24 V DC, common cathode, cable 5 m

Nr kat.: TELP624O-RGBW-SK

TELP624O-RGBW-SK TECHNOLINE - four-colour profile LED signalling beacon 620 mm; colours red + green + blue + white; 24 V DC; common cathode. Precise technical specifications, use and selection of…

Na zapytanie
37,26 €
bez VAT · 45,08 € z VAT
NASZA PORADA

TELP824O-Y, TECHNOLINE, yellow LED signalling Beacon 820 mm, 24 V DC, 5 m cable

Nr kat.: TELP824O-Y

TELP824O-Y TECHNOLINE - yellow profile LED signalling beacon 820 mm; colour yellow; 24 V DC. Precise technical specifications, use and selection of variants.

Na zapytanie
38,12 €
bez VAT · 46,12 € z VAT
NASZA PORADA

TELP824O-W, TECHNOLINE, white profile LED signalling Beacon 820 mm, 24 V DC, cable 5 m

Nr kat.: TELP824O-W

TELP824O-W TECHNOLINE - white profile LED signalling beacon 820 mm; colours white; 24 V DC. Precise technical specifications, use and selection of variants.

Na zapytanie
38,12 €
bez VAT · 46,12 € z VAT
NASZA PORADA

TELP724O-RGB-SA, TECHNOLINE, three-colour profile LED signalling beacon 720 mm, color red + green + white, 24 V DC, common anode, cable 5 m

Nr kat.: TELP724O-RGB-SA

TELP724O-RGB-SA TECHNOLINE - three-colour profile LED signalling beacon 720 mm; colors red + green + white; 24 V DC; common anode. Precise technical specifications, use and selection of variants.

Na zapytanie
38,12 €
bez VAT · 46,12 € z VAT
NASZA PORADA

TELP924O-Y, TECHNOLINE, yellow profile LED signalling Beacon 920 mm, 24 V DC, cable 5 m

Nr kat.: TELP924O-Y

TELP924O-Y TECHNOLINE - yellow profile LED signalling beacon 920 mm; colour yellow; 24 V DC. Precise technical specifications, use and selection of variants.

Na zapytanie
40,31 €
bez VAT · 48,78 € z VAT
NASZA PORADA

TELP924O-W, TECHNOLINE, white profile LED signalling Beacon 920 mm, 24 V DC, cable 5 m

Nr kat.: TELP924O-W

TELP924O-W TECHNOLINE - white profile LED signalling beacon 920 mm; colours white; 24 V DC. Precise technical specifications, use and selection of variants.

Na zapytanie
40,31 €
bez VAT · 48,78 € z VAT
NASZA PORADA

TELP824O-RGB-SA, TECHNOLINE, three-colour profile LED signalling beacon 820 mm, color red + green + white, 24 V DC, common anode, cable 5 m

Nr kat.: TELP824O-RGB-SA

TELP824O-RGB-SA TECHNOLINE - three-colour profile LED signalling beacon 820 mm; colors red + green + white; 24 V DC; common anode. Precise technical specifications, use and selection of variants.

Na zapytanie
40,62 €
bez VAT · 49,15 € z VAT
NASZA PORADA

TELP924O-RGB-SA, TECHNOLINE, three-colour profile LED signalling beacon 920 mm, color red + green + white, 24 V DC, common anode, cable 5 m

Nr kat.: TELP924O-RGB-SA

TELP924O-RGB-SA TECHNOLINE - three-colour profile LED signalling beacon 920 mm; colours red + green + white; 24 V DC; common anode. Precision technical specifications, use and selection of variants.

Na zapytanie
43,26 €
bez VAT · 52,35 € z VAT

Ceny zawierają opłatę recyklingową.

Profile LED Beacon

A profile LED light creates a lateral lighting surface that can be placed, for example, along the edge of the workplace. The catalog name for the light does not automatically mean a rotating or omnidirectional construction. The direction from which the state should be readable must be determined before selecting the length of the profile.

In the offer, there are implementations of TECHNOLINE TELP in various lengths and colors. For multicolor items, a common anode and common cathode are also found. This is an important electrical difference that cannot be overlooked when replacing a visually similar piece. General construction selection summarizes Signalling beacons.

Common anode and common cathode

In the standard connection, the common anode shares the positive lead of the light channels and their other ends are wound towards the negative pole. For the common cathode, the common negative lead and individual channels are activated from the positive side. This is Interface principle; specific conductors, currents and connections always determine the documentation of the beacon.

The list distinguishes, for example, TELP124O-RGB-SA and TELP124O-RGBW-SK. However, without a schematic, do not determine the order of the wires from the code. For a multicolor profile, also verify whether the wires create a color mix of the entire surface or another display intended by the manufacturer. RGB does not mean automatically digitally addressable strip.

What to compare before assembly

  • Tension of specific design, polarity and type of steering. Direct connection to the PLC requires conformity of connection and load capacity of outputs.
  • The length of the illuminating surface, the total mounting dimension and the position of the supply. The length of the profile and the required space in the frame may not be the same.
  • The collection of individual channels and their allowed confluence. Dimension the source according to a really possible combination, not just one color.
  • Fixing, cable passage and availability of end profile for service. The cover, temperature and cleaning mode shall be documented for the relevant assembly.

A longer light surface does not automatically solve the cover of the machine edge or the view from behind. When receiving, check the status recognition from the workplace and the approach direction. For point information directly at the stack, point-to-point information might be more suitable. Multi-function indicators.

Model example: voltage loss on supply

Consider a single-direction, educationally mined cable 5 m long, with a cross-sectional area of 0.5 mm², a current of 0.30 A, and a resistivity of 0.0175 Ω·mm²/m. For the supply and return wires, the voltage drop is calculated as 2 × 5 × 0.30 × 0.0175 / 0.5 = 0.105 V. This is a simplified calculation without contact resistance and temperature changes, not the parameters of the TELP cable.

On multiple channels, the common cable carries the sum of their currents, while each individual branch carries only the current of its channel. The calculation should be adjusted to the actual wiring. Practically, measure the voltage at the light in the most heavily loaded operational state.

Frequently asked questions

Can I shorten the profile or drill other mounting holes?

Only if the manufacturer allows such an adjustment. The finished profile beacon cannot be automatically considered as a free LED strip. A separate guide is used for this area Signal lamps and LED strips.

Is it enough to maintain voltage and length when changing?

Compare the joint anode or cathode, currents, cable lines and mounting. The opposite interface may require different control; is not a substitution of only the colour of the product.

Can the lighting profile confirm workplace safety?

The operational indication itself is not a safety function. The meaning of the color must be derived from the machine's control and documentation; turning off or turning on does not confirm the removal of danger.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.