PARK4SB, EMAS, pendant control station
PARK4SB EMAS – pendant control station. Technical parameters, application and compatibility check.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Complete EMAS crane pendant controls with single- and two-speed buttons, STOP button and optional key switch. Choose by number of movements, speed steps and cable outlet.
PARK4SB EMAS – pendant control station. Technical parameters, application and compatibility check.
PV3E30B2 EMAS – crane pendant control, PV, IP65, single-speed, 2. Technical parameters, application and compatibility check.
PV9T1X2222 EMAS – crane pendant control, PV, IP65, single-speed, 8. Technical parameters, application and compatibility check.
PV9E30B2222 EMAS – crane pendant control, PV, IP65, single-speed, 8. Technical parameters, application and compatibility check.
PV5E30B22 EMAS – crane pendant control, PV, IP65, single-speed, 4. Technical parameters, application and compatibility check.
PV9T1X4444 EMAS – crane pendant control, PV, IP65, two-speed, 8. Technical parameters, application and compatibility check.
PV9E30B4444 EMAS – crane pendant control, PV, IP65, two-speed, 8. Technical parameters, application and compatibility check.
PV5E30B44 EMAS – crane pendant control, PV, IP65, two-speed, 4. Technical parameters, application and compatibility check.
PV7E30B222 EMAS – crane pendant control, PV, IP65, single-speed, 6. Technical parameters, application and compatibility check.
PV7E30B444 EMAS – crane pendant control, PV, IP65, two-speed, 6. Technical parameters, application and compatibility check.
PV3E30B4 EMAS – crane pendant control, PV, IP65, two-speed, 2. Technical parameters, application and compatibility check.
Ceny zawierają opłatę recyklingową.
A pendant control lets the operator enter directions and other functions from the working position. The number of buttons describes the available control positions, but does not by itself indicate the number of motors or the method of direct switching. First compile a list of the required commands and assign electrical contacts to them. Then select the station, the supply cable and the mechanical suspension.
| Step | What to document |
|---|---|
| Identification | station type and a map of all commands |
| Operating requirements | number of steps, cable and suspension |
| Acceptance | individual commands and approved combinations |
The range includes, for example, PV3E30B2 and PV3E30B4 as well as larger stations PV5, PV7 and PV9. In its PV series, the manufacturer EMAS distinguishes between single- and two-speed versions. A two-step press can pass different commands depending on the wiring; it does not mean that the station itself controls the motor. Define the meaning of the first and second position and verify the link to the drive control.
For each control, record the direction, the contacts and the label on the head. Also describe what the equipment should do if opposite commands are given simultaneously by mistake. Mechanical and electrical interlocking must match the specific design. Do not assess the connection of the motor circuit only by the contact current rating; the type of load and the approved wiring are decisive.
The cable must suit the number of cores, the working movement and strain relief. The weight of the station must not inadvertently load the terminals. Check the cable entry, cable diameter, suspension and environmental conditions. Assess the degree of protection stated for the item together with the completed installation. Plan in advance for the grip area, legibility of direction symbols and use with gloves.
A model station for two directional movements with two speeds needs to distinguish four direction commands and their second steps. This does not yet produce a finished circuit diagram or the number of independent cores; common supply wires and contact logic may change it. Add stop, operation enable and any other functions actually required to the list. During acceptance, verify each command individually as well as the approved combinations.
Confirm whether the item includes fitted contacts, labelling elements, supply cable and suspension. A complete station and an empty enclosure are different items. After replacement, update the core map and the functional test record. Safety functions of the whole lifting equipment are assessed according to its documentation, not just by the presence of a red button.
It passes commands. The method of speed change is determined by the drive control and wiring.
Some positions may be reserved for a STOP function, a selector switch or a blanking plug. Check the specific configuration.
Related selection: Spare parts for crane pendant controls.
Documents for further verification: manufacturer's documentation.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.