EMAS latching push buttons that stay in the switched position after pressing. Choose by colour, contacts and illumination.
B100FB EMAS – latching control push button, white, 1 NO. Technical parameters, application, mounting and selection of the right variant.
B100FK EMAS – latching control push button, red, 1 NO. Technical parameters, application, mounting and selection of the right variant.
B100FM EMAS – latching control push button, blue, 1 NO. Technical parameters, application, mounting and selection of the right variant.
B100FS EMAS – latching control push button, yellow, 1 NO. Technical parameters, application, mounting and selection of the right variant.
B100FY EMAS – latching control push button, green, 1 NO. Technical parameters, application, mounting and selection of the right variant.
B100FH EMAS – latching control push button, black, 1 NO. Technical parameters, application, mounting and selection of the right variant.
Ceny zawierają opłatę recyklingową.
A latching push button makes it possible to maintain the selected mechanical position without holding it permanently. When designing the panel, it is therefore advisable to first determine whether the actuator should express a lasting request or a one-time command. For the second case, a momentary push button and separate pulse processing are usually more natural. Latching is not a universal solution for equipment memory and does not by itself decide what happens after a power loss.
This branch contains EMAS B100FB, B100FK, B100FM, B100FS, B100FY and B100FH, i.e. coloured versions with one normally open contact. For the green B100FY, the manufacturer states the Stay Put type, mounting size 22 mm and contact 1NO; the electrical rating is 4 A at 250 V AC in category AC-15. See EMAS B100FY technical sheet.
One NO contact means one normally open contact path, not confirmation of the actual state of the downstream equipment. A closed contact may represent a mode request, while the control does not allow this mode due to another condition. Therefore, choose the label according to the meaning of the selection, for example, not as an unconditional statement that a certain process is currently running.
The first state is the mechanical position of the actuator and the corresponding position of the contact. The second is the electrical signal, which can only be evaluated when the circuit is appropriately supplied. The third is the state of the program or the power section. These layers may end up differently after a power failure: the mechanical selection remains, the electrical signal disappears and the program reads default or saved data after restart, according to its design.
A maintained position therefore by itself means neither automatic start nor protection against restart. For the required response, the conditions of initialization, operator confirmation and evaluation of a still active input must be determined. If you are considering electronic output retention instead of mechanical selection, compare Touch switches. Their behaviour during a power failure is a separate property of the specific model.
Consider a panel where a latching push button requests the service display. At time 0 s, the selection is active. At time 10 s, the power fails and at time 12 s it is restored. In this model, the mechanical selection has not changed, but the program starts on the main screen and requires new confirmation. An active input after power-up must therefore not be mistakenly evaluated as a new intentional press.
The designer must describe separately how the confirmation is created and how the operator learns that the old selection has not yet been accepted. The times and screen responses are the author's assumptions, not properties B100FY. The example shows the difference between maintaining a mechanical command and its renewed acceptance; it does not address safety interlocking of hazardous movement.
Check the fastening of the actuator, the match of the contact block and the method of return from the latched position according to the documentation of the specific assembly. Do not assume the same release method for all products called “latching”. After mounting, test changing the selection and power interruption in both mechanical states. For short commands without position retention, compare Non-illuminated push buttons.
No. Mechanical position retention does not prove the purpose, design properties or safety suitability of the whole circuit.
No. Compare the function, number of contacts, mounting, electrical load and compatibility of the assembly. The same appearance does not guarantee the same behaviour.
If you cannot find the item you need in the e-shop, contact us with your enquiry and the complete specification of the required version.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.