Pneumatic suction cups

SMC vacuum suction cups for gripping and handling parts. Choose by shape, diameter and material of the cup according to the surface and weight of the part.

Filtry
Znaleziono 23 produktów

ZP2-B02EUS, SMC, vacuum suction cup, Ø2mm, short flat EU, silicone

Nr kat.: ZP2-B02EUS

ZP2-B02EUS, SMC: vacuum suction cup. Ø2mm, short flat EU, silicone. Selection by profile, mounting and vacuum.

Na zapytanie
3,40 €
bez VAT · 4,12 € z VAT

ZP3-02UN, SMC, vacuum suction cup, Ø2mm, flat, NBR

Nr kat.: ZP3-02UN

ZP3-02UN, SMC: vacuum suction cup. Ø2mm, flat, NBR. Selection by profile, mounting and vacuum.

Na zapytanie
3,61 €
bez VAT · 4,37 € z VAT

ZP06US, SMC, vacuum suction cup, Ø6mm, flat version, silicone

Nr kat.: ZP06US

ZP06US, SMC: vacuum suction cup. Ø6mm, flat version, silicone. Selection by profile, mounting and vacuum.

Na zapytanie
3,90 €
bez VAT · 4,71 € z VAT

ZP3-10BS, SMC, vacuum suction cup, Ø10mm, bellows, silicone

Nr kat.: ZP3-10BS

ZP3-10BS, SMC: vacuum suction cup. Ø10mm, bellows, silicone. Selection by profile, mounting and vacuum.

Na zapytanie
7,18 €
bez VAT · 8,68 € z VAT

ZP3-16BN, SMC, vacuum suction cup, Ø16mm, bellows, NBR

Nr kat.: ZP3-16BN

ZP3-16BN, SMC: vacuum suction cup. Ø16mm, bellows, NBR. Selection by profile, mounting and vacuum.

Na zapytanie
7,79 €
bez VAT · 9,43 € z VAT

ZP10BS, SMC, vacuum suction cup, Ø10mm, bellows version, silicone

Nr kat.: ZP10BS

ZP10BS, SMC: vacuum suction cup. Ø10mm, bellows version, silicone. Selection by profile, mounting and vacuum.

Na zapytanie
8,86 €
bez VAT · 10,72 € z VAT

ZP16BS, SMC, vacuum suction cup, Ø16mm, bellows version, silicone

Nr kat.: ZP16BS

ZP16BS, SMC: vacuum suction cup. Ø16mm, bellows version, silicone. Selection by profile, mounting and vacuum.

Na zapytanie
9,43 €
bez VAT · 11,41 € z VAT

ZPT32UN-B5, SMC, vacuum suction cup with mounting assembly, Ø32mm, vacuum suction cup with mounting assembly, connection female thread M5×0.8

Nr kat.: ZPT32UN-B5

ZPT32UN-B5, SMC: vacuum suction cup with mounting assembly. Ø32mm, vacuum suction cup with mounting assembly, connection female thread M5×0.8. Selection by profile, mounting and vacuum.

Na zapytanie
10,87 €
bez VAT · 13,15 € z VAT

Ceny zawierają opłatę recyklingową.

Pneumatic suction cups

The suction cup creates contact between the part and the vacuum circuit. Evacuating the air under the sealing lip creates a difference from the ambient pressure, which presses the part against the suction cup. This principle is explained by Festo in the vacuum technology overview. Actual contact with the work surface is decisive for gripping.

The listing includes the SMC ZP, ZP2, ZP3, ZP3E and ZPT series as well as holders. Examples from the range are ZP3-02UN a holder ZPT1-A5; their mutual compatibility is not confirmed by this.

Choice of shape and material

For ZP3, SMC distinguishes flat, grooved and bellows shapes. The flat shape is used for a straight undeformed surface; the bellows version is also used for inclined surfaces. Select the material according to the part, environment and the required behaviour after gripping. Always verify special suitability for the exact order code.

For your own comparison, prepare representative samples from several production batches and record the surface condition of each. Divide the test into seating, stabilisation, movement and release. For each phase, determine the observed result in advance, for example the position of the part after transfer or its release time. Also keep unsatisfactory results; a successful first attempt does not give an overview of process variability.

Mark the samples and keep their order when repeating. For each failure, record the observed state, not just the conclusion that the assembly does not work. Photos of the contact point and a record of the test will then serve as a basis for further comparison.

Mounting and replacement

Compare the holder with the suction cup according to the mounting interface. Look up the tightening torque for the specific thread and assembly in SMC mounting table. The manufacturer also distinguishes replacement methods according to design. After replacement, check the seating and securing of the suction cup; do not transfer the procedure of one type to all series.

Our own model of ideal pressure force

Let us consider a hypothetical closed circular effective area with a diameter of 30 mm and a uniform pressure difference of 50 kPa. Area A = π × 0.030² / 4 = 0.000707 m². From the definition of pressure as force per area, stated in the primary Festo overview, we get F = Δp × A = 50 000 × 0.000707 = approximately 35.3 N. With a model drop of the pressure difference to 35 kPa, the result is approximately 24.7 N.

This is the ideal normal force without a safety reserve. The diameter is not a value of any offered suction cup, and the calculation does not determine the load capacity or the order code. The actual effective area and permissible load must be confirmed by the documentation of the specific product.

SMC points out also on lateral forces and moments. The calculation therefore does not assess shear, peeling or movement with a displaced centre of gravity. It is not proof of safe holding of a load above persons.

Diagnostics after replacing a suction cup

If the fault appears after replacement, according to SMC diagnostic tables check the change in seating height, the joint between the suction cup and the adapter and leakage of the threaded connection. Record in which phase of the cycle the gripping deteriorates.

As our own acceptance procedure, we recommend comparing the record before and after replacement on the same samples and with the same motion program. Attach the assembly designation, date and change made to each result. Such a record allows the test to be repeated at the next repair and distinguishes a change of suction cup from a change of workpiece. Determine the number of repetitions according to the requirements of the specific process.

FAQ

Does the same diameter mean a direct replacement?

For ordering, compare the full code, interface and documentation of both variants. Make the decision only after verifying the whole assembly in the same work operation.

Is one successful gripping test enough?

Include all planned phases of the cycle and representative samples in the acceptance. Record the result against pre-defined criteria; one attempt does not prove repeatability.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.