VP542K-5YOD1-03FA, SMC, solenoid 3/2 pilot-operated poppet valve, 24 V DC, G 3/8

Cod. cat.: VP542K-5YOD1-03FA

VP542K-5YOD1-03FA, SMC, solenoid 3/2 pilot-operated poppet valve, 24 V DC, G 3/8. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
108,16 €
IVA esclusa · 130,87 € IVA inclusa

VF3133K-5YOD1-02F, SMC, solenoid pilot-operated valve

Cod. cat.: VF3133K-5YOD1-02F

VF3133K-5YOD1-02F, SMC, solenoid pilot-operated valve. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Su richiesta
109,55 €
IVA esclusa · 132,55 € IVA inclusa

VMPA1-M1H-KS-PI, Festo, solenoid valve, 556838

Cod. cat.: VMPA1-M1H-KS-PI

VMPA1-M1H-KS-PI Festo – solenoid valve, 556838. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
109,96 €
IVA esclusa · 133,05 € IVA inclusa

SY7320-5YO-02F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY7320-5YO-02F-Q

SY7320-5YO-02F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
109,96 €
IVA esclusa · 133,05 € IVA inclusa

VMPA1-M1H-K-PI, Festo, solenoid valve, 533347

Cod. cat.: VMPA1-M1H-K-PI

VMPA1-M1H-K-PI Festo – solenoid valve, 533347. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
112,20 €
IVA esclusa · 135,77 € IVA inclusa

CPE18-M1H-5L-1/4, Festo, solenoid valve, 163142

Cod. cat.: CPE18-M1H-5L-1/4

CPE18-M1H-5L-1/4, Festo, solenoid valve, 163142. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
113,63 €
IVA esclusa · 137,50 € IVA inclusa

CPE24-M1H-5L-3/8, Festo, solenoid valve, 163166

Cod. cat.: CPE24-M1H-5L-3/8

CPE24-M1H-5L-3/8 Festo – solenoid valve, 163166. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
116,49 €
IVA esclusa · 140,96 € IVA inclusa

SY5420-5DZ-C6-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY5420-5DZ-C6-Q

SY5420-5DZ-C6-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
116,49 €
IVA esclusa · 140,96 € IVA inclusa

VF3133-4YOD1-02F, SMC, solenoid pilot-operated valve

Cod. cat.: VF3133-4YOD1-02F

VF3133-4YOD1-02F SMC – solenoid pilot-operated valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
116,90 €
IVA esclusa · 141,45 € IVA inclusa

VMPA1-M1H-G-PI, Festo, solenoid valve, 533345

Cod. cat.: VMPA1-M1H-G-PI

VMPA1-M1H-G-PI Festo – solenoid valve, 533345. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
117,11 €
IVA esclusa · 141,70 € IVA inclusa

SY7320-5YO-C8F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY7320-5YO-C8F-Q

SY7320-5YO-C8F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
117,72 €
IVA esclusa · 142,44 € IVA inclusa

CPE14-M1BH-5L-1/8, Festo, 196941, solenoid valve

Cod. cat.: CPE14-M1BH-5L-1/8

CPE14-M1BH-5L-1/8 Festo – 196941, solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
118,13 €
IVA esclusa · 142,94 € IVA inclusa

MHA2-MS1H-5/2-2, 525101, solenoid valve, Festo

Cod. cat.: MHA2-MS1H-5/2-2

MHA2-MS1H-5/2-2, 525101, solenoid valve, Festo

Su richiesta
118,54 €
IVA esclusa · 143,43 € IVA inclusa
IL NOSTRO CONSIGLIO

VFS1120-5YO-01F-Q, SMC, 5/2 solenoid valve

Cod. cat.: VFS1120-5YO-01F-Q

VFS1120-5YO-01F-Q SMC – 5/2 solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
121,81 €
IVA esclusa · 147,39 € IVA inclusa

SS5Y5-20-10-00F-Q, SMC, sub-plate

Cod. cat.: SS5Y5-20-10-00F-Q

SS5Y5-20-10-00F-Q SMC – sub-plate. The exact variant is determined by the manufacturer's order code.

Su richiesta
121,78 €
IVA esclusa · 147,36 € IVA inclusa

SYJ7423-5LOU-01F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SYJ7423-5LOU-01F-Q

SYJ7423-5LOU-01F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
122,09 €
IVA esclusa · 147,73 € IVA inclusa

SY9320-5YO-02F-Q, SMC, solenoid valve

Cod. cat.: SY9320-5YO-02F-Q

SY9320-5YO-02F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
122,21 €
IVA esclusa · 147,88 € IVA inclusa

VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539

Cod. cat.: VUVS-L25-P53E-MD-G14-F8-1C1

VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
122,21 €
IVA esclusa · 147,88 € IVA inclusa

SY5420-5YO-C8F-Q, SMC, solenoid valve

Cod. cat.: SY5420-5YO-C8F-Q

SY5420-5YO-C8F-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
123,03 €
IVA esclusa · 148,87 € IVA inclusa

VUVS-L20-B52-D-Q8-F7-1C1, solenoid valve, 576516, Festo

Cod. cat.: VUVS-L20-B52-D-Q8-F7-1C1

solenoid valve, 576516, Festo

Su richiesta
125,48 €
IVA esclusa · 151,84 € IVA inclusa

SY9320-5YO-C10F-Q, solenoid pilot-operated valve, SMC

Cod. cat.: SY9320-5YO-C10F-Q

SY9320-5YO-C10F-Q, solenoid pilot-operated valve, SMC

Su richiesta
127,12 €
IVA esclusa · 153,81 € IVA inclusa

VNB403B-F25A, SMC, air-operated valve

Cod. cat.: VNB403B-F25A

VNB403B-F25A, SMC, air-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
129,98 €
IVA esclusa · 157,28 € IVA inclusa

MHE2-MS1H-5/2-QS-4, Festo, solenoid valve, 525117

Cod. cat.: MHE2-MS1H-5/2-QS-4

MHE2-MS1H-5/2-QS-4, Festo, solenoid valve, 525117. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
132,84 €
IVA esclusa · 160,74 € IVA inclusa

SY3220-5GU-M5-X10-Q, SMC, solenoid 5/2 valve, bistable, 24V DC

Cod. cat.: SY3220-5GU-M5-X10-Q

SY3220-5GU-M5-X10-Q, SMC, solenoid 5/2 valve, bistable, 24V DC. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
133,00 €
IVA esclusa · 160,93 € IVA inclusa

VH411-F04-L, SMC, manually operated valve

Cod. cat.: VH411-F04-L

VH411-F04-L SMC – manually operated valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
135,50 €
IVA esclusa · 163,95 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Pneumatic valves

The range includes SMC, Festo and TECHNOLINE pneumatic valves, including the TE3V/TE4V, SY, VQ, VX and VDW series. For selection, it is useful to separate the valve itself, its connection base and electrical accessories.

What the valve actually switches

The designation 5/2 expresses five main ports and two positions; 5/3 adds a third position with a defined connection of channels. The specific Festo VUVG-LK10-M52-AT-M5-1R8L-S is a monostable 5/2 with internal pilot supply. In contrast, VUVS-L25-P53E-MD-G14-F8-1C1 has the 5/3 function with an exhaust centre position. The number of coils alone does not replace reading the pneumatic symbol.

Closing a single flow path is a different requirement. Separate SMC VDW documentation describes direct-operated 2-way valves and distinguishes variants by medium. Documentation VX21/22/23 similarly distinguishes versions for water, air and other media. Inclusion in the pneumatic category therefore does not by itself confirm the suitability of each item for any liquid.

Selection starts with a description of the working sequence

For your own design, write down which branches should be pressurised and which exhausted for each command. In addition to the working cycle, describe a power failure, loss of air supply and restart. These are three separate situations; assess them according to the diagram of the specific valve and the whole machine.

Then compare the full order code, medium, required flow rate, working pressures and electrical connection. In the category Valves choose the functional version; Plates for terminals addresses the common arrangement of the assembly. For the decision, prepare a sketch of the actual line lengths, service clearances and consumer positions. Also record the measuring points for the acceptance test in the sketch.

Model calculation: volume of connecting hoses

Let us consider only a model assembly of eight hoses, each with an inner diameter of 6 mm and a length of 3 m. The geometric volume of one hose is V = π × d² × L / 4 = π × 0.006² × 3 / 4 = 0.0000848 m³, approximately 0.0848 litres. Eight hoses contain approximately 0.679 litres of internal space.

If each route is shortened to 1.5 m, the total drops to approximately 0.339 litres. The calculation compares only the geometry of two designs. It is not the free air consumption, switching time or parameters of the hoses or valves sold. For a time calculation, it would be necessary to add pressure conditions, the flow characteristic and the volume of the connected equipment.

Mounting and troubleshooting

Instructions SMC for VDW mounting require clean piping and prevention of sealing material entering the valve. When dismantling, it is necessary to disconnect the medium, release the pressure and switch off the power supply. A functional check follows assembly. Always take the specific mounting position and tightening from the documentation of the ordered version.

For the diagnostic record, compare the command, the voltage at the connected coil and the pressures upstream and downstream of the valve at the same moment. Record whether the fault occurs at the first switching, after warming up or during simultaneous operation of other branches. Such a distinction will help decide which part of the circuit to investigate further.

FAQ

Is an identical thread enough for replacement?

No. Compare the function, rest state, pilot version, medium and electrical equipment. The thread describes only one interface; also prepare the original diagram and the full order code.

Does an illuminated connector prove that the valve has switched?

Do not use the indicator light alone as acceptance proof of pneumatic function. Verify the actual response of the circuit. Select electrical parts in the category Accessories according to the exact version of the coil and connector.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.