UNDK 09G8914/D1, BAUMER, ultrasonic proximity sensor, 3–150mm, push-pull, PUR cable 2m, 4×0.08,, IP67
UNDK 09G8914/D1 – ultrasonic proximity sensor BAUMER. Range 3–150mm. Output push-pull. Cable PUR 2m, 4×0.08,. IP67.
Cambio 24,47 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
UNDK 09G8914/D1 – ultrasonic proximity sensor BAUMER. Range 3–150mm. Output push-pull. Cable PUR 2m, 4×0.08,. IP67.
UNDK 30N1713 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output NPN, normally open (NO). Cable 2m. IP67.
UNDK 09G8914/KS35AD1 – ultrasonic proximity sensor BAUMER. Range 3–150mm. Output push-pull. Cable outlet 200mm, connector M8. IP67.
UNCK 09G8914/KS35AD1 – ultrasonic proximity sensor BAUMER. Range 3–150mm. Output push-pull. Cable outlet 200mm, connector M8. IP67.
UNDK 30N1712/S14 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output NPN, normally open (NO). Connector M12. IP67.
UNDK 30N1713/S14 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output NPN, normally open (NO). Connector M12. IP67.
UNDK 30N3712/S14 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output NPN, normally closed (NC). Connector M12. IP67.
UNDK 30N3713/S14 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output NPN, normally closed (NC). Connector M12. IP67.
UNDK 30P1712/S14 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output PNP, normally open (NO). Connector M12. IP67.
UNDK 30P1713/S14 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output PNP, normally open (NO). Connector M12. IP67.
UNDK 30P3712/S14 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output PNP, normally closed (NC). Connector M12. IP67.
UNDK 30P3713/S14 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output PNP, normally closed (NC). Connector M12. IP67.
Ultrasonic sensor, UC500-L2-E5-V15, 188195, PEPPERL+FUCHS
Ultrasonic sensor, UC2000-L2-E4-V15, 188200, PEPPERL+FUCHS
Ultrasonic sensor, UC4000-L2-E5-V15, 188207, PEPPERL+FUCHS
UNDK 30N1712 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output NPN, normally open (NO). Cable 2m. IP67.
UNDK 30N3712 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output NPN, normally closed (NC). Cable 2m. IP67.
UNDK 30N3713 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output NPN, normally closed (NC). Cable 2m. IP67.
UNDK 30P1712 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output PNP, normally open (NO). Cable 2m. IP67.
UNDK 30P1713 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output PNP, normally open (NO). Cable 2m. IP67.
UNDK 30P3712 – ultrasonic proximity sensor BAUMER. Range 60–400mm. Output PNP, normally closed (NC). Cable 2m. IP67.
UNDK 30P3713 – ultrasonic proximity sensor BAUMER. Range 30–250mm. Output PNP, normally closed (NC). Cable 2m. IP67.
UNDK 30N1703/S14 – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally open (NO). Connector M12. IP67.
UNDK 30N3703/S14 – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally closed (NC). Connector M12. IP67.
UNDK 30P1703/S14 – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output PNP, normally open (NO). Connector M12. IP67.
I prezzi includono il contributo di riciclaggio.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
Compare the mounting holes, the position of the active surface and the cable or connector outlet. A low installation height does not mean that any obstacle can be placed in front of the face. Surrounding brackets and walls can reflect sound and affect detection. Also leave access to the setting buttons and indicators.
The design size does not indicate the measuring range. Verify the minimum and maximum working distance, blind zone and detection diagram for a suitable target. The switching version transmits a state; the analogue variant provides a continuous signal. Assess PNP/NPN, current or voltage analogue and communication separately from the NO/NC logic.
BALLUFF BUS006H,, designated BUS Q62K1-PWX-60/600-S92K,, is listed by the manufacturer as a rectangular version with two PNP NO/NC switching outputs and a five-pin M12 connector. This is an example of a design; the same parameters cannot be transferred to the entire Q62 series or to other rectangular sensors.
Carry out a test with the actual material and in all working positions. When several ultrasonic sensors operate together, verify mutual interference. Take the settings and any synchronisation from the manual of the exact order code.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Technical data BALLUFF BUS006H · Mounting ultrasonic sensors – microsonic.
A rectangular or flat housing is suitable where its mounting holes, height or direction of the active surface fit better. Decide according to the drawing and the space for the cable and sound beam.
The housing shape alone does not determine the range. For each variant, compare the working distance, blind zone, response and target size given in the detection diagram.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.