Ultrasonic sensor, UC2000-L2-E6-V15, 188202, PEPPERL+FUCHS
Ultrasonic sensor, UC2000-L2-E6-V15, 188202, PEPPERL+FUCHS
Rate 24,39 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
Ultrasonic sensor, UC2000-L2-E6-V15, 188202, PEPPERL+FUCHS
Ultrasonic sensor, UC4000-L2-E6-V15, 188208, PEPPERL+FUCHS
UNDK 30N1703 – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally open (NO). Cable 2m. IP67.
UNDK 30N3703 – ultrasonic proximity sensor BAUMER. Range 100–1000mm. Output NPN, normally closed (NC). Cable 2m. IP67.
Ultrasonic sensor, UC2000-F43-2KIR2-V17, 120329, PEPPERL+FUCHS
Ultrasonic sensor, UC300-F43-2KIR2-V17, 120332, PEPPERL+FUCHS
Ultrasonic sensor, retro-reflective 20x42x15,teach, DC,pnp,no,200mA,Sn:200,M8 connector4pol
UNDK 20P6914/S35A Baumer: ultrasonic sensor, 10–200 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
UNDK 20P6912/S35A Baumer: ultrasonic sensor, 40–400 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
URDK 20P6914/S35A Baumer: ultrasonic retro-reflective sensor, 0–200 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
URDK 20P6912/S35A Baumer: ultrasonic retro-reflective sensor, 0–400 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
UNDK 20P6903/S35A Baumer: ultrasonic sensor, 100–1000 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
URDK 20P6903/S35A Baumer: ultrasonic retro-reflective sensor, 0–1000 mm, PNP, normally open (NO), connector M8 – technical parameters and selection | TECHNOLINE
Ultrasonic sensor, UCC500-30GH70-IE2R2-V15, 238410, PEPPERL+FUCHS
Ultrasonic sensor, UCC2000-30GH70-IE2R2-V15, 238411, PEPPERL+FUCHS
Ultrasonic sensor, UCC500-30GH70-UE2R2-V15, 238414, PEPPERL+FUCHS
Ultrasonic sensor, UCC2000-30GH70-UE2R2-V15, 238415, PEPPERL+FUCHS
Ultrasonic sensor, UCC3500-30GH70-IE2R2-V15, 238412, PEPPERL+FUCHS
Ultrasonic sensor, UCC3500-30GH70-UE2R2-V15, 238416, PEPPERL+FUCHS
Ultrasonic sensor, UCC500-30GH70S-IE2R2-V15, 238418, PEPPERL+FUCHS
Ultrasonic sensor, UCC2000-30GH70S-IE2R2-V15, 238419, PEPPERL+FUCHS
Ultrasonic sensor, UCC500-30GH70S-UE2R2-V15, 238422, PEPPERL+FUCHS
Ultrasonic sensor, UCC2000-30GH70S-UE2R2-V15, 238423, PEPPERL+FUCHS
Ultrasonic sensor, UCC6000-30GH70-IE2R2-V15, 238413, PEPPERL+FUCHS
Ultrasonic sensor, UCC6000-30GH70-UE2R2-V15, 238417, PEPPERL+FUCHS
Prices include the recycling fee.
Rectangular and compact ultrasonic sensors offer block-shaped, flat and other non-threaded designs for mounting on a machine or bracket. When choosing, the shape and size of the housing, the direction of emission and the space required for the sound beam are decisive. The designation Q62, S40 or another series must correspond to the drawing of the specific product.
Compare the mounting holes, the position of the active surface and the cable or connector outlet. A low installation height does not mean that any obstacle can be placed in front of the face. Surrounding brackets and walls can reflect sound and affect detection. Also leave access to the setting buttons and indicators.
The design size does not indicate the measuring range. Verify the minimum and maximum working distance, blind zone and detection diagram for a suitable target. The switching version transmits a state; the analogue variant provides a continuous signal. Assess PNP/NPN, current or voltage analogue and communication separately from the NO/NC logic.
BALLUFF BUS006H,, designated BUS Q62K1-PWX-60/600-S92K,, is listed by the manufacturer as a rectangular version with two PNP NO/NC switching outputs and a five-pin M12 connector. This is an example of a design; the same parameters cannot be transferred to the entire Q62 series or to other rectangular sensors.
Carry out a test with the actual material and in all working positions. When several ultrasonic sensors operate together, verify mutual interference. Take the settings and any synchronisation from the manual of the exact order code.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Technical data BALLUFF BUS006H · Mounting ultrasonic sensors – microsonic.
A rectangular or flat housing is suitable where its mounting holes, height or direction of the active surface fit better. Decide according to the drawing and the space for the cable and sound beam.
The housing shape alone does not determine the range. For each variant, compare the working distance, blind zone, response and target size given in the detection diagram.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.