MK5101, IFM, magnetic sensor, MKT3028BBPKG/G/0, 3M/ZH/AS
MK5101 IFM – magnetic sensor, M8, PNP. Industrial product for automation, detection or measurement.
Cambio 24,43 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
ifm magnetic sensors (e.g. MK5101) for sensing piston position on pneumatic cylinders with T-slot. Choose by slot, output and connection.
MK5101 IFM – magnetic sensor, M8, PNP. Industrial product for automation, detection or measurement.
I prezzi includono il contributo di riciclaggio.
This category contains MK5101 with the full designation MKT3028BBPKG/G/0.3M/ZH/AS. When choosing a replacement, keep both codes: the short order number and the full version. IFM classifies MK5101 among sensors with a GMR cell, i.e. a semiconductor magnetoresistive principle; it is not a reed contact. See the IFM cylinder sensor overview.
MK5101 is designed for the T-slot. It has a PNP/NO switching output, 10–30 V DC supply and a PUR cable 0.3 m long with a three-contact A-coded M8, connector. The body measures 25 × 5 × 6.5 mm. These are parameters of the specific model according to the datasheet MK5101.
When comparing versions, separate the slot shape, output function and connection. Do not solve a requirement for a C-slot, a different output type or a long fixed cable just by matching the IFM brand. First draw up a list of machine requirements and confirm for each whether this specific code meets it.
For MK5101 the manufacturer specifies a fixing eccentric with a combined tool slot and an internal hexagon of 1.5 mm. A rubber positioning element and a cable clip are included in the delivery. The mounting design and package contents are documented by the Czech datasheet MK5101.
Include access to the fixing and space for the mating connector in the installation preparation. Check that the cable does not remain taut or caught when surrounding parts move. Before removing the original unit, document its position and cable route; after replacement, record the actually verified setting.
When replacing a sensor on a T-slot cylinder, MK5101 may be a candidate for an input expecting PNP/NO. However, complete the approval of the replacement only after comparing the drawing and wiring. Add the monitored position, the cable used and the result of the function test to the acceptance record; this creates a basis for future service of the same machine.
No. Also compare the connection method and the number and assignment of contacts. When replacing, it is not enough to check that the connectors look similar.
The piston position signal alone does not prove the clamping force or correct gripping of the part. The evaluation conditions for the whole operation must match the design and requirements of the machine.
Other versions can be compared among magnetic sensors. For connection use Sensor Cables and Connectors; help with assessing the assembly is available from technical support.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.