RS1P08H1, EMAS, 8-pin relay socket for DIN rail for relays and compatible counters
RS1P08H1 is an EMAS 8-pin socket for DIN rail mounting 35mm. It serves as a plug-in base for compatible relays and counters, for example the RZ1D1C. series
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Time on the display, starting, reset and memory
RS1P08H1 is an EMAS 8-pin socket for DIN rail mounting 35mm. It serves as a plug-in base for compatible relays and counters, for example the RZ1D1C. series
EMAS RZ1D1S-5 is a digital time relay with a changeover output 1CO. The variant is intended for a 220VAC power supply and timing from 0.1s to 99h59min.
EMAS RZ1D1S-2 is a digital time relay with a changeover output 1CO. The variant is intended for a 24VAC/DC power supply and timing from 0.1s to 99h59min.
EMAS RZ1D1R-2 is a digital time relay with a changeover output 1CO. The variant is intended for a 24VAC/DC power supply and timing from 0.1s to 99h59min.
EMAS RZ1D1R-5 is a digital time relay with a changeover output 1CO. The variant is intended for a 220VAC power supply and timing from 0.1s to 99h59min.
ENDA ETM2432-230VAC is a digital panel countdown timer with external start, reset and gate inputs. It has two relays and, for this variant, a 230VAC. power supply
ENDA ETM2432-SM is a digital panel countdown timer with external start, reset and gate inputs. It has two relays and, for this variant, a 10–30VDC/8–24VAC. power supply
Prices include the recycling fee.
A digital time relay makes it easier to work with a numerically entered preset. When choosing, however, also note which value the display is currently showing: the required time, the remaining time or the parameter being set. For the operator, clear information about the progress and completion of the step is important, not just the number of displayed digits.
The listing includes EMAS RZ1D1S-2, RZ1D1S-5, RZ1D1R-2, RZ1D1R-5 and ENDA ETM2432 in two catalogue versions. There is also the socket RS1P08H1. A separate accessory does not replace a timer; assess its suitability according to the specific assembly.
Write down the required interval in an unambiguous unit. A display with a colon does not necessarily represent a decimal number; the meaning of the individual fields is determined by the format setting. Before handing the machine over to the operator, check the unit and the available change step. The display resolution does not in itself express the timing accuracy or the delay of the connected actuator.
EMAS for digital timers RZ1 specifies a changeover contact. A numerical setting therefore does not guarantee contactless switching. For simple adjustment with a scale, compare Analog Time Relays; choose the output separately according to the controlled circuit.
ENDA ETM2432 manual describes counting down with hours–minutes and minutes–seconds formats and separate START, RESET and GATE inputs. With GATE, the countdown is paused and continues when released. RESET returns the preset according to the described mode. Check the specific behaviour of the outputs in the relevant timing diagram.
For the application, draw your own sequence of events: the first command, another command while running, reaching zero and starting the next step. Next to each event, state the expected state of the load. Then select the corresponding device mode. The button label or the input name alone are not enough to define the entire sequence.
Leave space for the terminals, connected cables and removal of the device during service. Determine in advance who may change the preset and who may change the whole mode. The operating procedure should include clear confirmation of the change and a return to the operating screen. After saving, check the actually displayed unit and value, not just the last key pressed.
Retaining the set time does not prove that the remaining time is retained. Therefore, include a separate test of a power interruption during a step in progress in the acceptance. After power returns, monitor the preset, the current value and the output separately. Write down the requirement for operator confirmation after a failure before choosing the device; do not rely on it without documented behaviour of the specific mode.
If the time does not run, first check the selected triggering method and the state of the inputs. For ETM2432, the manual specifies a minimum duration of the contact command of 50 ms. Do not transfer this value to EMAS or other series. Recording the actual command helps distinguish a setting error from a signal that is too short.
Consider an ideal countdown of 90 seconds, which we pause after 25 seconds for 12 seconds. 65 seconds remain and completion occurs 102 seconds after the start. We assume the elapsed time is retained and there is no further delay. This is an author's model of the required sequence, not a product parameter or a guarantee of memory during a power failure.
No. Verify an interruption by the control input and a loss of power as two different operating states. Their identical result cannot be assumed.
For a batch, the number of recorded events is decisive. The sensor connection and pulse checking are described in Digital Counters.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.