Phone +420 774 723 123 Cart · 0 · empty

Cylindrical ultrasonic sensors

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Filters
Found 453 products

UR30-CM3DT, LANBAO, ultrasonic distance sensor 180–3000mm, TTL232, Cable 2m

Cat. no.: UR30-CM3DT

UR30-CM3DT LANBAO – ultrasonic sensor, 180–3000mm, Cable 2m, TTL232. Industrial product for automation, measurement and control.

On request
146,41 €
excl. VAT · 177,16 € incl. VAT

UR30-CM4DU5, LANBAO, ultrasonic distance sensor 200–4000mm, 0-5V, Cable 2m

Cat. no.: UR30-CM4DU5

UR30-CM4DU5 LANBAO – ultrasonic sensor, 200–4000mm, Cable 2m. Industrial product for automation, measurement and control.

On request
146,41 €
excl. VAT · 177,16 € incl. VAT

UR30-CM4DU10, LANBAO, ultrasonic distance sensor 200–4000mm, 0-10V, Cable 2m

Cat. no.: UR30-CM4DU10

UR30-CM4DU10 LANBAO – ultrasonic sensor, 200–4000mm, Cable 2m. Industrial product for automation, measurement and control.

On request
146,41 €
excl. VAT · 177,16 € incl. VAT

UR30-CM4DU10-E2, LANBAO, ultrasonic sensor, Sn 200–4000 mm, connector M12/4 pins

Cat. no.: UR30-CM4DU10-E2

UR30-CM4DU10-E2 – LANBAO ultrasonic distance sensor. Sn 200–4000 mm, connector M12/4 pins, IP67. Delivery on request from Technoline – datasheet, technical support, invoice.

On request
148,05 €
excl. VAT · 179,14 € incl. VAT

BUS007E, BALLUFF, ultrasonic sensor M18M1, range 25–250 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007E

BUS007E Balluff: ultrasonic sensor M18M1, range 25–250 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

BUS007F, BALLUFF, ultrasonic sensor M18M1, range 30–350 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007F

BUS007F Balluff: ultrasonic sensor M18M1, range 30–350 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

BUS007H, BALLUFF, ultrasonic sensor M18M1, range 65–600 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007H

BUS007H Balluff: ultrasonic sensor M18M1, range 65–600 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

BUS007K, BALLUFF, ultrasonic sensor W18M1, range 25–250 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007K

BUS007K Balluff: ultrasonic sensor W18M1, range 25–250 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

BUS007L, BALLUFF, ultrasonic sensor W18M1, range 30–350 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007L

BUS007L Balluff: ultrasonic sensor W18M1, range 30–350 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

BUS007M, BALLUFF, ultrasonic sensor W18M1, range 65–600 mm, IO-Link 1.1 / PNP/NPN

Cat. no.: BUS007M

BUS007M Balluff: ultrasonic sensor W18M1, range 65–600 mm, IO-Link 1.1 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
154,07 €
excl. VAT · 186,42 € incl. VAT

UR30-CM4DT, LANBAO, ultrasonic distance sensor 200–4000mm, TTL232, Cable 2m

Cat. no.: UR30-CM4DT

UR30-CM4DT LANBAO – ultrasonic sensor, 200–4000mm, TTL232, cable 2 m PVC. Industrial product for automation, measurement and control.

On request
154,20 €
excl. VAT · 186,58 € incl. VAT

UR30-CM4DT-E2, LANBAO, ultrasonic sensor, TTL232, Sn 200–4000 mm, connector M12/4 pins

Cat. no.: UR30-CM4DT-E2

UR30-CM4DT-E2 – LANBAO ultrasonic distance sensor. Sn 200–4000 mm, connector M12/4 pins, TTL232, IP67. Delivery on request from Technoline – datasheet, technical support, invoice.

On request
155,84 €
excl. VAT · 188,56 € incl. VAT

BUS0020, BALLUFF, ultrasonic sensor M18M1, range 25–250 mm, IO-Link 1.0 / PNP/NPN

Cat. no.: BUS0020

BUS0020 Balluff: ultrasonic sensor M18M1, range 25–250 mm, IO-Link 1.0 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
164,06 €
excl. VAT · 198,51 € incl. VAT

BUS004Z, BALLUFF, ultrasonic sensor M18M1, range 65–600 mm, IO-Link 1.0 / PNP/NPN

Cat. no.: BUS004Z

BUS004Z Balluff: ultrasonic sensor M18M1, range 65–600 mm, IO-Link 1.0 / PNP/NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
164,06 €
excl. VAT · 198,51 € incl. VAT

BUS0022, BALLUFF, ultrasonic sensor M30M1, range 30–350 mm, PNP

Cat. no.: BUS0022

BUS0022 Balluff: ultrasonic sensor M30M1, range 30–350 mm, PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
165,02 €
excl. VAT · 199,68 € incl. VAT

BUS002J, BALLUFF, ultrasonic sensor M30M1, range 30–350 mm, NPN

Cat. no.: BUS002J

BUS002J Balluff: ultrasonic sensor M30M1, range 30–350 mm, NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
165,02 €
excl. VAT · 199,68 € incl. VAT

BUS0036, BALLUFF, ultrasonic sensor M30M1, range 200–2 000 mm, NPN

Cat. no.: BUS0036

BUS0036 Balluff: ultrasonic sensor M30M1, range 200–2 000 mm, NPN. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
165,02 €
excl. VAT · 199,68 € incl. VAT

BUS0039, BALLUFF, ultrasonic sensor M30M1, range 200–2 000 mm, PNP

Cat. no.: BUS0039

BUS0039 Balluff: ultrasonic sensor M30M1, range 200–2 000 mm, PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
165,02 €
excl. VAT · 199,68 € incl. VAT

Prices include the recycling fee.

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Illustrative cylindrical ultrasonic sensor in a metal threaded housing
Illustrative example of a design or application; verify the availability of the specific version on the product page.

How to choose an ultrasonic sensor M12, M18 or M30

First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.

Output and PLC connection

For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.

  • Compare the housing length, thread, space behind the connector and position of the face.
  • Verify the supply, number of contacts and wiring diagram of the exact variant.
  • Take into account the size and inclination of the target, the detection diagram and the required response.
  • When installing several sensors, check the spacing and synchronisation support.

Typical use and verification in the machine

Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.

View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.

All ultrasonic sensors and selection guide · Sensor Cables and Connectors

Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.

Selection questions

Does a larger thread M30 automatically mean a longer range than M18?

The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.

Is a switching output enough for continuous distance measurement?

A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.

Cookies on this website