VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539
VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539. A solenoid valve electrically controls the direction of compressed air flow.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
3/2, 5/2 and 5/3 pneumatic directional valves with electrical, pneumatic or manual actuation. Choose by function, rest position, port and coil voltage.
VUVS-L25-P53E-MD-G14-F8-1C1, Festo, solenoid valve, 575539. A solenoid valve electrically controls the direction of compressed air flow.
SY5420-5YO-C8F-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.
solenoid valve, 576516, Festo
SY9320-5YO-C10F-Q, solenoid pilot-operated valve, SMC
VNB403B-F25A, SMC, air-operated valve. A solenoid valve electrically controls the direction of compressed air flow.
MHE2-MS1H-5/2-QS-4, Festo, solenoid valve, 525117. A solenoid valve electrically controls the direction of compressed air flow.
SY3220-5GU-M5-X10-Q, SMC, solenoid 5/2 valve, bistable, 24V DC. A solenoid valve electrically controls the direction of compressed air flow.
VH411-F04-L SMC – manually operated valve. When selecting, verify the connection, size and other parameters of the specific variant.
SY5220-5DZ-C6-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.
CPE14-M1CH-5J-1/8, Festo, 550239, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.
R-3-1/4-B, Festo, roller lever valve, 8985. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.
EAV2000-F02-5YO-Q, SMC, two-stage soft-start valve, for Europe. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.
MFH-3-1/8, Festo, solenoid valve, 7802. A solenoid valve electrically controls the direction of compressed air flow.
CPE14-M1BH-5J-1/8 Festo – 196939, solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.
EAV3000-F03-5YO-Q, two-stage soft-start valve, for Europe, SMC
EAV3000-F03-5YZ-Q, SMC, two-stage soft-start valve, for Europe. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.
EAV4000-F04-5YO-Q, two-stage soft-start valve, for Europe, SMC
VFS2300-5FZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.
solenoid valve; voltage? 24VDC; 170265; Festo
solenoid valve; voltage: 24VDC; 170267; Festo
AV3000-F03S-5KOZ-A, SMC, two-stage soft-start valve. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
VNB703B-F50A, SMC, air-operated 2/2 valve, for compressed air, water, oil and vacuum. A solenoid valve electrically controls the direction of compressed air flow.
JMFH-5-1/2-S Festo – solenoid valve, 35548. When selecting, verify the connection, size and other parameters of the specific variant.
VNC711A-50A-5DZ-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.
Ceny zawierają opłatę recyklingową.
A directional valve controls the connection of the supply, working paths and exhaust according to its functional symbol. For selection, you need the required state of the actuator and the behaviour when the command and energy change. The number of ways alone does not describe the rest or centre position.
| Step | What to document |
|---|---|
| Identification | symbol, number of ways and positions |
| Operating requirements | pilot pressure and electrical actuation |
| Acceptance | circuit switching and exhaust |
The range here includes TE3V/TE4V, SMC SY, VQ, VX and VDW series as well as Festo valves. For a service replacement, start with the function of the original circuit and the full part code. Similar-looking bodies may represent different circuits.
At TECHNOLINE, they represent TE3V310-10-NC-DC24V-LD a TE3V310-10-NO-DC24V-LD two rest variants 3/2. NC means the supply path to the working output is closed in the home state, NO means it is open. When selecting, therefore, draw the required media path with the electrical command disconnected.
TE4V310-10-NC-DC24V-LD is 5/2, while TE4V330C-10-NC-DC24V-LD is a 5/3 with a closed centre position. NC or NO alone is not a complete description of all channels of a 5-way valve. For example, Festo VUVS-L25-P53E-MD-G14-F8-1C1 uses an exhaust centre. Read the specific arrangement from the symbol; do not create a replacement simply by counting the coils.
Festo datasheet 8042543 explicitly states pilot operation and internal pilot air supply. For your own selection sheet, therefore, record the pressure of the working branch and the requirements of the pilot stage separately. For an external pilot, verify its separate supply according to the diagram. Electrical voltage alone does not confirm that the pneumatic conditions for switching are met.
For 2-way valves, the medium and the pressure differential are further distinguished. SMC manual VQ20/30 requires a minimum differential of 0.01 MPa for opening. Catalogue VX21/22/23 separates the highest system pressure from the highest working pressure differential. Record both input values in the comparison; a high pressure upstream of the valve alone is not enough.
For our own example, let us assume pressures measured against the same reference: 0.43 MPa upstream of the valve and 0.425 MPa downstream. The difference is Δp = 0.43 − 0.425 = 0.005 MPa, i.e. 5 kPa. With our own design requirement of at least 20 kPa, this model situation does not comply, even though there is significant overpressure at the inlet.
If, in the second model situation, the outlet pressure drops to 0.40 MPa, the difference increases to 30 kPa. This only meets the considered pressure differential condition. The example does not determine the flow rate, opening time or suitability of a specific valve. The actual values must be determined during the working sequence, not taken from the compressor setting.
Before disconnecting, ensure a de-energised and depressurised state. The VQ20/30 manual requires a functional test and leak check after mounting. For this series, it also points out that a locked manual override can change the response to switching off the electrical command. Therefore, include the manual override position in the check before start-up.
As our own diagnostic procedure, record the command, voltage and pressure conditions at the same time. Compare a standalone cycle with simultaneous operation of other consumers. If the problem occurs only in the assembly, add to the check Plates for terminals and the connected line. Look up the electrical variant via Accessories, always according to the full code.
This cannot be assumed without changing the required function. Also include the behaviour of the third position in the comparison and verify whether the working sequence actually needs it.
Only in combination with the exact variant and its documentation. For orientation in the whole range, use Pneumatic valves; inclusion of a product alone does not confirm its suitability for water, oil or vacuum.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.