KCJ08-99, SMC, plug-in stem with check valve, stem Ø8mm
KCJ08-99, SMC, plug-in stem with check valve, stem Ø8mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Push-in fittings for quick, tight connection of pneumatic tubes without tools – straight, elbow, branch and barb. Choose by tube outside diameter and shape.
KCJ08-99, SMC, plug-in stem with check valve, stem Ø8mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.
KQ2LE08-00A, SMC, elbow bulkhead fitting, tube Ø8mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.
KQ2TW06-00A, SMC, cross fitting, 4× tube Ø6mm. Cross connection of four pneumatic branches at a single point.
KQ2D10-00A, SMC, three-way delta manifold, 3× tube Ø10mm. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.
KQ2U10-12A, SMC, Y-connector, reducer Ø10mm↔Ø12mm. Angled Y-branching for routing three branches with suitable tube geometry.
KCH08-00, SMC, self-sealing straight fitting, tube Ø8mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.
KQ2E10-00A, SMC, bulkhead fitting, tube Ø10mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.
KQ2VD06-02AS, SMC, elbow double manifold with thread, tube Ø6mm, male R1/4. Air branching from threaded port R1/4 into several tube outlets. With pre-applied thread seal.
KQ2L16-04AS, SMC, elbow fitting 90°, tube Ø16mm, male R1/2. Elbow connection of the tube to threaded port R1/2; changes the line direction at the component. With pre-applied thread seal.
KQ2E12-00A, SMC, bulkhead fitting, tube Ø12mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.
KQ2E12-03A, SMC, bulkhead fitting, tube Ø12mm, female Rc3/8. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.
KQ2U12-16A, SMC, Y-connector, reducer Ø12mm↔Ø16mm. Angled Y-branching for routing three branches with suitable tube geometry.
KQ2VD08-04AS, SMC, elbow double manifold with thread, tube Ø8mm, male R1/2. Air branching from threaded port R1/2 into several tube outlets. With pre-applied thread seal.
KCE06-00, SMC, self-sealing bulkhead fitting, tube Ø6mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.
KQ2VT06-02A, SMC, elbow triple manifold with thread, tube Ø6mm, male R1/4. Air branching from threaded port R1/4 into several tube outlets.
KQ2ZD06-03AS, SMC, four-way threaded manifold, tube Ø6mm, male R3/8. Air branching from threaded port R3/8 into several tube outlets. With pre-applied thread seal.
KQ2VT06-02AS, SMC, elbow triple manifold with thread, tube Ø6mm, male R1/4. Air branching from threaded port R1/4 into several tube outlets. With pre-applied thread seal.
KQ2UD04-06A, SMC, pneumatic push-in fitting plastic U-type, pack of 10 pcs. A pneumatic fitting connects a tube to another element of the distribution or connects two tubes. The tube diameter…
pneumatic push-in fitting plastic U-type; SMC
KM11-04-08-10, SMC, distribution block, 10× outlet Ø4mm / inlet Ø8mm. A multi-way compressed air distributor for clear connection of consumer branches.
KQG2L08-03S, SMC, stainless steel elbow fitting 316, tube Ø8mm, thread R3/8. Elbow connection of the tube to threaded port R3/8 male; changes the line direction at the component.
Ceny zawierają opłatę recyklingową.
Select push-in fittings according to what they actually connect: two tubes, a tube with a threaded port, or a tube with the plug-in stem of another part. The range includes Pneuflex and SMC versions in various shapes and sizes. For ordering, therefore, first draw both opposite interfaces. The category name alone does not determine the design of each item.
Section of fitting KQ2 from SMC separates the gripping of the tube by a toothed element from its sealing. The release button engages the gripping. The sealing function and mechanical securing therefore have their own design elements.
The selection record should include the tube outer diameter, the full designation of the counterpart and the required line direction. Record the inner diameter separately for assessing the passage. For the thread, require its system and size; a value in inches without the system is not enough to decide on a replacement. Record separately whether you are selecting a thread for connecting the medium or a thread for fixing into the panel. The similar appearance of these points can hide a different purpose when ordering.
To continue in one axis, open Straight fittings, for changing direction Elbow fittings and for splitting the line Branch fittings. Our own practical rule is to select the functional diagram first and only then the smallest body. For a confined assembly, you also need to draw the access of fingers, tools and the path for pulling out the tube during replacement.
For a replacement part, prepare a simple diagram of the original and intended assembly. Both must show all ends that change during the intervention. If the replacement adds an adapter, also add the new detachable point and its accessibility. This gives you a basis for choosing between a direct replacement and a route change, without deciding solely by the size of the available component.
Before intervention, ensure the safe state of the equipment and verify that no pressure remains in the section being changed. For your own mounting check, compare the actual parts with the drawing, mark the individual branches and check access to all detachable points. Also record the fixing of the line around the fitting. The purpose of the check is to reveal whether future replacement of one tube will require dismantling other components.
Pneuflex for the straight PU family describes inserting the tube and releasing it by pressing the collet. Always relate the exact mounting procedure to the selected version.
Let us consider an explicitly model closed passage with a diameter of 5 mm and an overpressure of 0.7 MPa. A force F = p × A acts on the flat closure. The area A = π × 5² / 4 is approximately 19.6 mm²; since 0.7 MPa corresponds to 0.7 N/mm², the force is about 13.7 N. This is our own illustration of the effect of pressure, not the load capacity of the fitting, the tube pull-out force or the recommended working pressure of the product. The model explains why the state of a connection cannot be assessed by hand alone.
In the service record, separate a problem at the tube inlet, at the threaded counterpart and in the body of the assembly. Record whether the symptom appeared after replacement, during line movement or only during simultaneous consumption. Your own comparison procedure always changes a single circumstance: line layout, verified counterpart or specific connecting part. This way, a selection error can be distinguished from a mounting problem without randomly changing the whole branch.
Check which interface the value belongs to. Record the tube diameter, the plug-in stem diameter and the mounting hole size as different quantities.
Yes, take the specific service operation into account in the design. Assess the free space for inserting, releasing and pulling out the line, not just for the body dimension.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.