Analogue inductive sensors measure the distance of a metal object and convert it into a 0–10 V or 4–20 mA output. They are suitable for measuring position, deflection, eccentricity or thickness. Choose by measuring range, output type and housing size.
LR18XCF05LIUM-E2 – LANBAO analogue inductive sensor. Sn 1–5 mm, Analogue 0-10V and 0-20mA. In stock at Technoline – datasheet, technical support, invoice.
LR18BF05LUM-E2 – LANBAO analogue inductive sensor. Sn 1–5 mm, PNP, NO, connector M12/4 pins, IP67. Delivery on request from Technoline – datasheet, technical support, invoice.
LR30BN15LUM-E2 – LANBAO analogue inductive sensor. Sn 3–15 mm, PNP, NO, connector M12/4 pins, IP67. Delivery on request from Technoline – datasheet, technical support, invoice.
LR30XCF10LIUM-E2 – LANBAO analogue inductive sensor. Sn 1–10 mm, Analogue 0-10V and 0-20mA. Delivery on request from Technoline – datasheet, technical support, invoice.
IB080006 from IPF is an analogue inductive distance-measuring sensor. M8, Sn 0–4 mm, 15–30 V DC, Analogue, PUR cable 2 m, 3 wires, IP67.
Na zapytanie
204,62 €
bez VAT · 247,59 € z VAT
Ceny zawierają opłatę recyklingową.
Analogue inductive sensors in special applications
An analogue inductive sensor converts a change in the distance of a metal target into a continuous electrical signal. It is suitable where you need to monitor position or the course of a movement rather than just information that a single limit position has been reached.
LANBAO LR12X-M-E2. Original product image. Source: manufacturer LANBAO. Check the output and measuring range according to the order code.
0–10 V or 4–20 mA output
The output type must match the analogue input of the control system. Check the supply, wiring, common reference and permissible load. Also set the signal range in the input card and the PLC program; an identical connector alone does not guarantee a correct connection.
Measuring range and accuracy
Determine the working area according to the measuring range of the specific model. The switching distance of a standard inductive sensor does not replace it. Take into account the material, size and orientation of the target, linearity, repeatability and temperature drift. Verify the conversion of the signal to millimetres on the actual part at several known positions.
Analogue output and environmental resistance
An analogue output says nothing about resistance to high pressure, chemicals or welding fields. If the application requires these properties, they must be confirmed for the selected model as well. Also assess the cable and connector and leave a margin against mechanical contact with the target.
What to prepare for selection
Specify the material and dimensions of the target, the minimum and maximum distance, the required accuracy, the rate of change, the PLC input type and the environmental conditions. A more detailed procedure can be found in the guide to analogue sensors. Other designs can be compared in the category Special sensors.
Pliki cookies na tej stronie
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Ustawienia cookies
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Techniczne pliki cookies
Zawsze aktywne
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Analityczne pliki cookies
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.