Valves

3/2, 5/2 and 5/3 pneumatic directional valves with electrical, pneumatic or manual actuation. Choose by function, rest position, port and coil voltage.

Filtri
Trovati 174 prodotti

SY513-5YO-C8F-Q, SMC, solenoid valve

Cod. cat.: SY513-5YO-C8F-Q

SY513-5YO-C8F-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
73,31 €
IVA esclusa · 88,71 € IVA inclusa

SY5160-5LOU-C6-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY5160-5LOU-C6-Q

SY5160-5LOU-C6-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
73,51 €
IVA esclusa · 88,95 € IVA inclusa

SY7120-4YO-02F-X10-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY7120-4YO-02F-X10-Q

SY7120-4YO-02F-X10-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
73,72 €
IVA esclusa · 89,20 € IVA inclusa

SY5220-5DO-01F-Q, solenoid valve, SMC

Cod. cat.: SY5220-5DO-01F-Q

SY5220-5DO-01F-Q, solenoid pilot-operated valve, SMC

Su richiesta
74,13 €
IVA esclusa · 89,70 € IVA inclusa

SY5240-5LZ-Q, solenoid pilot-operated valve , SMC

Cod. cat.: SY5240-5LZ-Q

SY5240-5LZ-Q, solenoid pilot-operated valve , SMC

Su richiesta
75,77 €
IVA esclusa · 91,68 € IVA inclusa

VUVG-LK10-T32C-AT-M5-1R8L-S, solenoid valve, 8042542, Festo

Cod. cat.: VUVG-LK10-T32C-AT-M5-1R8L-S

solenoid valve; voltage: 24VDC; frequency: 2 Hz; 8042542; Festo

Su richiesta
76,79 €
IVA esclusa · 92,92 € IVA inclusa

VMPA1-M1H-M-PI, Festo, solenoid valve, 533342

Cod. cat.: VMPA1-M1H-M-PI

VMPA1-M1H-M-PI Festo – solenoid valve, 533342. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
76,99 €
IVA esclusa · 93,16 € IVA inclusa

SYJ712-5DZ-01F-F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SYJ712-5DZ-01F-F-Q

SYJ712-5DZ-01F-F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
79,04 €
IVA esclusa · 95,64 € IVA inclusa

SY3120-5WAOU-M5-Q, solenoid pilot-operated valve, SMC

Cod. cat.: SY3120-5WAOU-M5-Q

SY3120-5WAOU-M5-Q, solenoid pilot-operated valve, SMC

Su richiesta
79,45 €
IVA esclusa · 96,14 € IVA inclusa

SY3240-5MOZ-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY3240-5MOZ-Q

SY3240-5MOZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
79,94 €
IVA esclusa · 96,73 € IVA inclusa

VXZ242FZ3AA, SMC, solenoid pilot-operated 2/2 valve, for water

Cod. cat.: VXZ242FZ3AA

VXZ242FZ3AA SMC – solenoid pilot-operated 2/2 valve, for water. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
80,68 €
IVA esclusa · 97,62 € IVA inclusa

JSY1240T-5LOZ, SMC, solenoid valve

Cod. cat.: JSY1240T-5LOZ

JSY1240T-5LOZ, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
80,68 €
IVA esclusa · 97,62 € IVA inclusa

SY5220-5YO-01F-Q, solenoid pilot-operated valve, SMC

Cod. cat.: SY5220-5YO-01F-Q

SY5220-5YO-01F-Q, solenoid pilot-operated valve, SMC

Su richiesta
81,09 €
IVA esclusa · 98,12 € IVA inclusa

SY5120-4DZ-01F-Q, SMC, solenoid valve

Cod. cat.: SY5120-4DZ-01F-Q

SY5120-4DZ-01F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
81,09 €
IVA esclusa · 98,12 € IVA inclusa

VUVS-LT25-M52-MD-G14-F8, solenoid valve, 8035181, Festo

Cod. cat.: VUVS-LT25-M52-MD-G14-F8

VUVS-LT25-M52-MD-G14-F8, solenoid valve, 8035181, Festo

Su richiesta
81,38 €
IVA esclusa · 98,46 € IVA inclusa

VUVS-L20-M52-MD-G18-F7-1C1, solenoid valve, 575264, Festo

Cod. cat.: VUVS-L20-M52-MD-G18-F7-1C1

solenoid valve; 575264; voltage: 24 VDC; Festo

Su richiesta
81,50 €
IVA esclusa · 98,61 € IVA inclusa

VQC2101N-5B1, SMC, solenoid valve

Cod. cat.: VQC2101N-5B1

VQC2101N-5B1 SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
81,70 €
IVA esclusa · 98,86 € IVA inclusa

VUVS-LK25-B52-D-G14-1B2-S, Festo, solenoid valve. 8043214

Cod. cat.: VUVS-LK25-B52-D-G14-1B2-S

VUVS-LK25-B52-D-G14-1B2-S, Festo, solenoid valve. 8043214. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
82,32 €
IVA esclusa · 99,60 € IVA inclusa

SY5340-5DZ-02F-Q, SMC, solenoid 3 position, closed centre, 5 port, 24 V DC, plate mounting

Cod. cat.: SY5340-5DZ-02F-Q

SY5340-5DZ-02F-Q, SMC, solenoid 3 position, closed centre, 5 port, 24 V DC, plate mounting. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
85,59 €
IVA esclusa · 103,57 € IVA inclusa

SY5220-5YO-C6F-Q, SMC, solenoid 5/2 valve, bistable, 24V DC

Cod. cat.: SY5220-5YO-C6F-Q

SY5220-5YO-C6F-Q, SMC, solenoid 5/2 valve, bistable, 24V DC. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
85,59 €
IVA esclusa · 103,57 € IVA inclusa

SY7220-5DO-02F-Q, SMC, solenoid valve, 24 V DC

Cod. cat.: SY7220-5DO-02F-Q

SY7220-5DO-02F-Q, SMC, solenoid valve, 24 V DC. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
85,59 €
IVA esclusa · 103,57 € IVA inclusa

SY7220-5YO-02F-Q, solenoid valve, SMC

Cod. cat.: SY7220-5YO-02F-Q

SY7220-5YO-02F-Q, solenoid 5/2 valve, bistable, 24VDC, SMC

Su richiesta
85,59 €
IVA esclusa · 103,57 € IVA inclusa

SY5220-5YO-C8F-Q, solenoid valve, SMC

Cod. cat.: SY5220-5YO-C8F-Q

SY5220-5YO-C8F-Q, solenoid 5/2 valve, bistable, 24V DC, SMC

Su richiesta
85,59 €
IVA esclusa · 103,57 € IVA inclusa

SY9120-5YO-02F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY9120-5YO-02F-Q

SY9120-5YO-02F-Q SMC – solenoid pilot-operated valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
85,96 €
IVA esclusa · 104,01 € IVA inclusa

SY5320-5DO-01F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY5320-5DO-01F-Q

SY5320-5DO-01F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
86,00 €
IVA esclusa · 104,06 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Pneumatic directional valves

A directional valve controls the connection of the supply, working paths and exhaust according to its functional symbol. For selection, you need the required state of the actuator and the behaviour when the command and energy change. The number of ways alone does not describe the rest or centre position.

Selection data Valves

Step What to document
Identification symbol, number of ways and positions
Operating requirements pilot pressure and electrical actuation
Acceptance circuit switching and exhaust

The range here includes TE3V/TE4V, SMC SY, VQ, VX and VDW series as well as Festo valves. For a service replacement, start with the function of the original circuit and the full part code. Similar-looking bodies may represent different circuits.

Number of positions and rest state

At TECHNOLINE, they represent TE3V310-10-NC-DC24V-LD a TE3V310-10-NO-DC24V-LD two rest variants 3/2. NC means the supply path to the working output is closed in the home state, NO means it is open. When selecting, therefore, draw the required media path with the electrical command disconnected.

TE4V310-10-NC-DC24V-LD is 5/2, while TE4V330C-10-NC-DC24V-LD is a 5/3 with a closed centre position. NC or NO alone is not a complete description of all channels of a 5-way valve. For example, Festo VUVS-L25-P53E-MD-G14-F8-1C1 uses an exhaust centre. Read the specific arrangement from the symbol; do not create a replacement simply by counting the coils.

Pilot pressure and medium are separate criteria

Festo datasheet 8042543 explicitly states pilot operation and internal pilot air supply. For your own selection sheet, therefore, record the pressure of the working branch and the requirements of the pilot stage separately. For an external pilot, verify its separate supply according to the diagram. Electrical voltage alone does not confirm that the pneumatic conditions for switching are met.

For 2-way valves, the medium and the pressure differential are further distinguished. SMC manual VQ20/30 requires a minimum differential of 0.01 MPa for opening. Catalogue VX21/22/23 separates the highest system pressure from the highest working pressure differential. Record both input values in the comparison; a high pressure upstream of the valve alone is not enough.

Model calculation: pressure upstream of the valve is insufficient

For our own example, let us assume pressures measured against the same reference: 0.43 MPa upstream of the valve and 0.425 MPa downstream. The difference is Δp = 0.43 − 0.425 = 0.005 MPa, i.e. 5 kPa. With our own design requirement of at least 20 kPa, this model situation does not comply, even though there is significant overpressure at the inlet.

If, in the second model situation, the outlet pressure drops to 0.40 MPa, the difference increases to 30 kPa. This only meets the considered pressure differential condition. The example does not determine the flow rate, opening time or suitability of a specific valve. The actual values must be determined during the working sequence, not taken from the compressor setting.

Mounting and targeted diagnostics

Before disconnecting, ensure a de-energised and depressurised state. The VQ20/30 manual requires a functional test and leak check after mounting. For this series, it also points out that a locked manual override can change the response to switching off the electrical command. Therefore, include the manual override position in the check before start-up.

As our own diagnostic procedure, record the command, voltage and pressure conditions at the same time. Compare a standalone cycle with simultaneous operation of other consumers. If the problem occurs only in the assembly, add to the check Plates for terminals and the connected line. Look up the electrical variant via Accessories, always according to the full code.

FAQ

Is the 5/2 valve a replacement for 5/3?

This cannot be assumed without changing the required function. Also include the behaviour of the third position in the comparison and verify whether the working sequence actually needs it.

Can the permitted medium be determined from the series designation?

Only in combination with the exact variant and its documentation. For orientation in the whole range, use Pneumatic valves; inclusion of a product alone does not confirm its suitability for water, oil or vacuum.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.