Cross Limit Switches

EMAS CSM cross limit switches for sensing several positions in one device. Choose by number of directions and switching sequence.

Filtri
Trovati 3 prodotti
−10 % IL NOSTRO CONSIGLIO DISPONIBILE

CSM02, EMAS, cross limit switch, 180°, 1 step forward + 1 step backward, 200 mm, IP65

Cod. cat.: CSM02

CSM02 EMAS – cross limit switch, IP65. Technical parameters, application and compatibility check.

Disponibile 5 pz e oltre
51,23 € 56,92 €
IVA esclusa · 61,99 € IVA inclusa
−10 % IL NOSTRO CONSIGLIO DISPONIBILE

CSM04, EMAS, cross limit switch, 360°, 2 steps forward + 2 steps backward, 200 mm, IP65

Cod. cat.: CSM04

CSM04 EMAS – cross limit switch, IP65. Technical parameters, application and compatibility check.

Disponibile 5 pz e oltre
53,38 € 59,31 €
IVA esclusa · 64,59 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

CSM10, EMAS, cross limit switch, 360°, continuous rotation, 200 mm, IP65

Cod. cat.: CSM10

CSM10 EMAS – cross limit switch, IP65. Technical parameters, application and compatibility check.

Disponibile 5 pz e oltre
67,00 €
IVA esclusa · 81,07 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Cross Limit Switches

A cross limit switch converts a mechanical action on the arm into a change in the position of a rotary mechanism. In the design, the point of first contact with the cam is not the only decisive factor. You need to know the entire pass, the subsequent position of the arms and the behaviour when travelling in the opposite direction. The result is determined by the switching diagram of the specific version, not by the cross-shaped appearance of the actuator.

CSM02, CSM04 a CSM10

The range includes EMAS CSM02, CSM04 and CSM10. The manufacturer's overview distinguishes for CSM02 the version 180°, for CSM04 the version 360° with two forward and two backward steps, and for CSM10 the continuously rotating version 360°. These variants are not functionally interchangeable; see the EMAS CSM series overview.

For CSM02 the manufacturer states a metal housing, an arm of 200 mm, protection IP65 and electrical category AC-21A with a rating of 20 A at 400 V AC. The parameters are documented by technical sheet CSM02. This current is not a general permission for direct motor switching and does not automatically apply to all utilisation categories or other models.

Approach direction and sequence of states

Before selecting, draw the position of the cam relative to the axis, the active arm and the direction of movement. Then determine in which positions the required electrical signal should occur and what should happen on return. With a reciprocating machine movement, the same sequence as when passing in one direction need not be repeated. Nor does it follow that four visible arms automatically mean four independent contact circuits.

The mechanism must complete the prescribed movement without unwanted skipping or repeated engagement of another arm. The cam, bearing play and switch position all affect the actual angle of rotation. The design therefore includes the tolerance of the smallest and largest engagement. No general designation 180° or 360° by itself says at what partial angle a specific contact switches.

Model example: travel of the arm tip

Consider a model contact point at a distance of 150 mm from the axis and a rotation of 20°. The arc travel of this point is s = r × φ = 150 × 20π / 180, i.e. approximately 52.4 mm. This value is not the longitudinal displacement of the cam: that depends on its path and the shape of the contact surface.

The radius and angle were chosen to explain the geometry and are not the prescribed operating travel of the CSM. The example shows why the setting cannot be derived only from the arm length given in the catalogue. In a real assembly, the switching diagram and the actual transmission of movement throughout the pass are checked. Also allow for the possibility of the arm rebounding and changing position on reverse contact.

Mounting and operational verification

The bracket must hold the axis in the specified position and the surroundings must leave room for the movement of all arms. The switch does not replace a fixed mechanical travel stop. Before commissioning, test the pass and return under limit operating conditions and verify that the control processes the correct contact sequence. For the cable entry and cover, observe the manufacturer's mounting conditions.

For a simple approach to a plunger or roller, compare Metal Limit Switches IP65. An overview of other designs is offered by the parent category Limit Switches.

Is 360° a switching angle specification?

No. It describes the angular design of the mechanism; specific contact changes must be read from the diagram of the relevant model.

Does a cross switch guarantee safe stopping of travel?

Not by itself. The entire required function must be assessed, including control response, run-down and mechanical arrangement.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.