Electrical Consumables

Electrical consumables – cable lugs and ferrules, cable glands, conduits and conduit glands, cable ties, cable chains, trunking and DIN rails, sockets and bells. Choose by conductor cross-section and mounting method.

Sottocategorie

Filtri
Trovati 101 prodotti
DISPONIBILE

ONKA 8007-1000, ONKA, 8007, crimp cable ferrule - pack of 1000ks

Cod. cat.: ONKA 8007-1000

ONKA 8007-1000 ONKA – 8007, crimp cable ferrule - pack of 1000ks. Key data: 0.5 × 8 mm, 1000 pcs. Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
9,05 €
IVA esclusa · 10,95 € IVA inclusa
DISPONIBILE

ONKA-8051-200, ONKA, crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 200ks

Cod. cat.: ONKA-8051-200

ONKA-8051-200 ONKA – crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 200ks. Key data: 1.5 mm². Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
9,38 €
IVA esclusa · 11,34 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

ONKA 8014-1000, ONKA, 8014, crimp cable ferrule - pack of 1000 pcs

Cod. cat.: ONKA 8014-1000

ONKA 8014-1000 ONKA – 8014, crimp cable ferrule - pack of 1000 pcs. Key data: 1.0 × 8 mm. Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
9,38 €
IVA esclusa · 11,35 € IVA inclusa
DISPONIBILE

ONKA-8087-200, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 200ks

Cod. cat.: ONKA-8087-200

ONKA-8087-200 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 200ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
10,28 €
IVA esclusa · 12,43 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

Holder, TECHNOLINE, screw-on cable holder for cable ties, pack of 100ks

Cod. cat.: Držák

Holder TECHNOLINE – screw-on cable holder for cable ties, pack of 100ks. Key data: electrical installation accessories. Exact technical data for selecting the cable tie / cable holder type.

Disponibile 5 pz e oltre
12,28 €
IVA esclusa · 14,86 € IVA inclusa
DISPONIBILE

ONKA-8052-200, ONKA, insulated crimp cable lug M6 for conductors 0.5–1.5 mm², pack of 200 pcs

Cod. cat.: ONKA-8052-200

ONKA-8052-200 ONKA – insulated crimp cable lug M6 for conductors 0.5–1.5 mm², pack of 200 pcs. Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
12,65 €
IVA esclusa · 15,31 € IVA inclusa
DISPONIBILE

ONKA-8089-200, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 200ks

Cod. cat.: ONKA-8089-200

ONKA-8089-200 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 200ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

Disponibile 5 pz e oltre
12,73 €
IVA esclusa · 15,41 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

HKP015015R1A, EMAS, flexible cable chain, inner width 20mm, inner height 15 mm

Cod. cat.: HKP015015R1A

HKP015015R1A EMAS – flexible cable chain, inner width 20mm, inner height 15 mm. Exact technical data for selecting the cable chain type.

Disponibile 5 pz e oltre
12,90 €
IVA esclusa · 15,60 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

HKP020025R3A, EMAS, flexible cable chain, inner width 25mm, inner height 20 mm

Cod. cat.: HKP020025R3A

HKP020025R3A EMAS – flexible cable chain, inner width 25mm, inner height 20 mm. Exact technical data for selecting the cable chain type.

Disponibile 5 pz e oltre
14,17 €
IVA esclusa · 17,14 € IVA inclusa

FSA1919B, Turkuaz, CABLE TIE MOUNT, adhesive, 19x19mm

Cod. cat.: FSA1919B

FSA1919B Turkuaz – CABLE TIE MOUNT, adhesive, 19x19mm. Key data: electrical installation accessories, 19 × 19 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
0,08 €
IVA esclusa · 0,10 € IVA inclusa

TVK-1, ONKA, CABLE TIE MOUNT, screw-on

Cod. cat.: TVK-1

TVK-1 ONKA – CABLE TIE MOUNT, screw-on. Key data: electrical installation accessories. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
0,12 €
IVA esclusa · 0,15 € IVA inclusa
IL NOSTRO CONSIGLIO

PG13.5, EGTECH, cable gland grey

Cod. cat.: PG13.5

PG13.5 EGTECH – cable gland grey. Exact technical data for selecting the cable protection / gland type.

Su richiesta
0,33 €
IVA esclusa · 0,40 € IVA inclusa
IL NOSTRO CONSIGLIO

M16, EGTECH, x1,5mm; cable gland grey, 16 × 1.5 mm

Cod. cat.: M16

M16 EGTECH – x1,5mm; cable gland grey, 16 × 1.5 mm. Exact technical data for selecting the cable protection / gland type.

Su richiesta
0,37 €
IVA esclusa · 0,45 € IVA inclusa
IL NOSTRO CONSIGLIO

M20, EGTECH, x1,5mm; cable gland grey, 20 × 1.5 mm

Cod. cat.: M20

M20 EGTECH – x1,5mm; cable gland grey, 20 × 1.5 mm. Exact technical data for selecting the cable protection / gland type.

Su richiesta
0,43 €
IVA esclusa · 0,52 € IVA inclusa

AG10025, ONKA, WHITE NYLON CABLE TIE 2, 5x100mm, 100ks

Cod. cat.: AG10025

AG10025 ONKA – WHITE NYLON CABLE TIE 2, 5x100mm, 100ks. Key data: electrical installation accessories, 5 × 100 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
0,86 €
IVA esclusa · 1,04 € IVA inclusa

AG15025, ONKA, WHITE NYLON CABLE TIE, cable tie 2, 5x150mm, 100ks

Cod. cat.: AG15025

AG15025 ONKA – WHITE NYLON CABLE TIE, cable tie 2, 5x150mm, 100ks. Key data: electrical installation accessories, 5 × 150 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
0,86 €
IVA esclusa · 1,04 € IVA inclusa

AG25016, ONKA, WHITE NYLON CABLE TIE, cable tie 1, 6 x 250 mm, 100ks

Cod. cat.: AG25016

AG25016 ONKA – WHITE NYLON CABLE TIE, cable tie 1, 6 x 250 mm, 100ks. Key data: electrical installation accessories, 6 × 250 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
0,98 €
IVA esclusa · 1,19 € IVA inclusa
IL NOSTRO CONSIGLIO

M32, EGTECH, x1,5mm; cable gland grey, 32 × 1.5 mm

Cod. cat.: M32

M32 EGTECH – x1,5mm; cable gland grey, 32 × 1.5 mm. Exact technical data for selecting the cable protection / gland type.

Su richiesta
0,98 €
IVA esclusa · 1,19 € IVA inclusa
IL NOSTRO CONSIGLIO

HKP020025ZDA, EMAS, cable chain end bracket 25mm, OUTER connection

Cod. cat.: HKP020025ZDA

HKP020025ZDA EMAS – cable chain end bracket 25mm, OUTER connection. Exact technical data for selecting the cable chain type.

Su richiesta
0,98 €
IVA esclusa · 1,19 € IVA inclusa

AG16025, ONKA, WHITE NYLON CABLE TIE, cable tie 2, 5x100mm, 100ks

Cod. cat.: AG16025

AG16025 ONKA – WHITE NYLON CABLE TIE, cable tie 2, 5x100mm, 100ks. Key data: electrical installation accessories, 5 × 100 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
1,02 €
IVA esclusa · 1,24 € IVA inclusa

AG25020, Turkuaz, WHITE NYLON CABLE TIE 2, 0 x 250 mm, 100ks

Cod. cat.: AG25020

AG25020 Turkuaz – WHITE NYLON CABLE TIE 2, 0 x 250 mm, 100ks. Key data: electrical installation accessories, 0 × 250 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
1,11 €
IVA esclusa · 1,34 € IVA inclusa

AG20025, ONKA, WHITE NYLON CABLE TIE 2, 5x200mm, 100ks

Cod. cat.: AG20025

AG20025 ONKA – WHITE NYLON CABLE TIE 2, 5x200mm, 100ks. Key data: electrical installation accessories, 5 × 200 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
1,39 €
IVA esclusa · 1,68 € IVA inclusa

AG14036, ONKA, WHITE NYLON CABLE TIE 3.6X140MM, 100ks

Cod. cat.: AG14036

AG14036 ONKA – WHITE NYLON CABLE TIE 3.6X140MM, 100ks. Key data: electrical installation accessories, 3.6 × 140 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
1,43 €
IVA esclusa · 1,73 € IVA inclusa
IL NOSTRO CONSIGLIO

T1-E 25x40 G01163, IBOCO, plastic wiring duct

Cod. cat.: T1-E 25x40 G01163

T1-E 25x40 G01163 IBOCO – plastic wiring duct. Key data: 25x40. Exact technical data for selecting the DIN rail / wiring duct type.

Su richiesta · in multipli di 2 pz
2,58 €
IVA esclusa · 3,12 € IVA inclusa

AG30048, ONKA, WHITE NYLON CABLE TIE 4.8X300MM, 100ks, Turkuaz

Cod. cat.: AG30048

AG30048 ONKA – WHITE NYLON CABLE TIE 4.8X300MM, 100ks, Turkuaz. Key data: electrical installation accessories, 4.8 × 300 mm. Exact technical data for selecting the cable tie / cable holder type.

Su richiesta
3,15 €
IVA esclusa · 3,81 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Electrical consumables

Electrical consumables link the design of electrical equipment with its actual mechanical execution. A well-chosen terminal is no help if the conductor termination does not fit into it; a quality cable in turn needs a suitable wall entry and a well-thought-out route. This category brings together material for terminating, organising, protecting and fixing cabling as well as selected connection and doorbell devices. When selecting, it pays to proceed interface by interface, not just by brand or the nearest size.

Overview of subcategories

Start with the function of the part, not its similar appearance

For stranded conductors connected to suitable terminals, use insulated crimp ferrules; crimp cable lugs are used for a screw connection with a ring. A ferrule and a lug are therefore not two interchangeable variants of the same termination. They differ in contact shape, the space required for connection and the tool used to make the joint. The cross-section figure alone does not determine whether the termination suits a specific terminal.

For organising conductors inside a control cabinet, choose trunking and suitable fixing elements. A DIN rail carries devices; it is not a substitute for cable trunking. A conduit protects the route, while its end fitting handles the transition to the equipment. A cable gland works with the cable sheath and the opening in the wall. For moving equipment, routing cables in an energy chain is added. Each of these parts answers a different design question.

Four values that must not be confused

The conductor cross-section in mm² describes the conductive part. The outer diameter of an insulated conductor or of the whole cable in millimetres is a different dimension, needed for example when assessing the entry and the space. The length of the metal sleeve of a ferrule is not the same as the overall length with the insulating collar. The nominal thread of a gland, in turn, does not say how wide a cable its seal will actually accept.

In the working list, therefore record electrical and mechanical data separately. For termination, it is the cross-section, conductor construction and receiving terminal. For the entry, add the outer cable diameter, the thread or mounting hole, the wall thickness and the environment. The need to assess the cable, thread and sealing interface together is explained in the LAPP technical guide to cable glands. The specific ranges, however, must come from the data sheet of the product being ordered.

A fixed route and repeated movement require a different brief

For a fixed installation, draw the route including entries into the control cabinet, slack at the doors and access to devices. For movement, also describe the stroke, the position of the fixed points, the smallest permissible cable radius and the duty cycle. Flexible cable chains choose as part of a moving system, not as a simple substitute for plastic trunking.

The chain length reflects the stroke arrangement and the allowance for the bend. The manufacturer igus distinguishes these relationships in its documentation for calculating energy chain length. The dimensional similarity of another series does not justify adopting its design tables. Already at the design stage, leave space for the end brackets and any chain guidance; the moving bend must not intrude into the operator area or adjacent mechanics.

Mounting interfaces determine the result

For a crimped joint, the conductor, termination and crimping tool belong to a single work procedure. The suitability of this combination and the quality of workmanship are emphasised by Weidmüller in its ferrule documentation. Therefore use the collar colour as an aid to organising work, not as the sole proof of the cross-section. With a twin ferrule, the termination must also be permitted by the receiving terminal.

For a conduit, check its size and profile, compatibility of the fitting and how the route is fixed. For a cable tie, the permissible bundle, material and fixing method are essential. An adhesive base needs a suitable substrate; the mere presence of an adhesive layer is no proof of long-term load capacity in all positions. Each interface has its own conditions and the resulting assembly must meet them all at once.

Worked example: bill of materials for a small assembly

Consider our own production plan for eight identical assemblies. Each has 24 separate stranded conductors and both ends are to be terminated with a single ferrule permitted by the terminals in question. The basic requirement is 8 × 24 × 2 = 384 pieces. Another twelve ferrules are needed for twelve test terminations. In total, the plan therefore counts on 396 pieces, not 192 based on the number of conductors.

If the selected order item contained one hundred pieces, four packs would cover exactly this model requirement. Such a calculation does not, however, merge different cross-sections or lengths into one item: with two types of termination, the quantities are itemised separately. Openings in the enclosure, glands, fixing bases and conduit ends are counted separately in the same way. The reserve is determined by your own production process; it is not a universal percentage.

Ordering and maintenance without unnecessary mix-ups

For small material, a short internal description containing the function, size, series and order unit helps. On receipt, distinguish between a piece, a bag and a whole pack. In the workshop, keep similar terminations separate and attach information on the tool used. When repairing, do not select a replacement only by colour or photo; also compare the size of the contact part and the documentation of the connected equipment.

Socket and doorbell devices belong in this overview as separate functional parts. For sockets and plugs 230V / 400V the complete connection system is assessed; for a transformer, the powered appliance and its consumption. The mains part of the equipment must be designed and carried out by a qualified person. The designation of one part does not transfer the protection rating, current capacity or other properties to an arbitrarily assembled whole.

FAQ

Is a larger accessory size always the safer choice?

No. An oversized termination may fit the conductor or terminal poorly, and an unsuitable sealing range of a gland may not match the cable. The size must suit both sides of the joint.

Can a spare part be identified just by the material designation?

Material is only one piece of information. Add the design series, dimensions, environment, mounting conditions and the function of the original part. For a repair, the complete order code is more useful than a general name.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.