RZT7-03ZRS-KP0, SICK, magnetic sensor, 1070847
RZT7-03ZRS-KP0 SICK – magnetic sensor, M8. Industrial product for automation, detection or measurement.
Cambio 24,43 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
SICK magnetic sensors for piston position sensing (RZT, MZT, MZC), continuous MPS position measurement and RE safety door switches. Choose by purpose, slot and connection.
RZT7-03ZRS-KP0 SICK – magnetic sensor, M8. Industrial product for automation, detection or measurement.
MZT7-03VPS-KW0 SICK – magnetic sensor, PNP, NO, cable 2m. Industrial product for automation, detection or measurement.
MZC1-2V2PS-KP0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.
RE13-SAC SICK – magnetic sensor, M8, Reed contacts. Industrial product for automation, detection or measurement.
RE27-SA68L SICK – magnetic sensor, M12, Reed contacts. Industrial product for automation, detection or measurement.
MZCG-1Z7PS-KR0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.
MPS-032TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-064TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-064TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
MPS-096TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-096TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
MPS-128TSTU0 SICK – magnetic sensor, T. Industrial product for automation, detection or measurement.
MPS-128TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.
I prezzi includono il contributo di riciclaggio.
The range combines three different tasks: switching the piston position, continuous measurement of its position and safety monitoring of protective doors. In addition to versions MPS-032, MPS-064, MPS-096 and MPS-128 it includes RZT7, MZT7, MZC1, MZCG as well as RE13-SAC and RE27-SA68L. Before comparing parameters, therefore, determine which task the ordered part is to perform.
For a service replacement, separate mechanical from electrical compatibility. A similar designation or the same number of wires is not enough. Store the cylinder type, slot profile, expected input function and the exact code of the original sensor in the work sheet.
The specific MPS-064TSTU0, 1045669 is designed for the T-slot and has a measuring range of 64 mm, while the housing measures 77 mm. The sheet specifies analogue 0–10 V or 4–20 mA; the corresponding connected output is activated.
Consider MPS where the control system needs a position value within a defined section. Before ordering, draw the required limits, the space for the housing and the connection route. Prepare a suitable control input and scaling for the specific variant; do not transfer the parameters of this example to all MPS lengths.
RE1/RE2 are magnetic safety switches for movable guards in combination with a suitable safety evaluation unit. Selection requires a risk assessment and professional commissioning according to the SICK manual RE1/RE2. It is not a substitute for a standard cylinder sensor.
RE13-SAC, 1059503 contains a sensor with actuator, two switching contacts and a four-pole M8. RE27-SA68L, 1059509 additionally has a signalling contact and a 0.2 m cable with an eight-pole M12. Both sheets leave fault detection to the downstream safety logic. The PL achieved by the whole assembly therefore cannot be determined from the switch designation.
The position alone does not prove the clamping force or correct gripping of the part. Evaluate these requirements separately according to the machine.
No. Compare the number and assignment of contacts with the specific sheet and the approved wiring. Buying a cable does not replace the assessment of the safety circuit.
Other brands can be compared among magnetic sensors. For connection, continue with Sensor Cables and Connectors; selection documents are covered by technical support.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.