TPC10-G02, TECHNOLINE, straight push-in fitting, tube Ø10mm, male thread G1/4
TPC10-G02, TECHNOLINE: straight push-in fitting; tube Ø10mm, male thread G1/4. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
Cambio 24,47 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
SMC, Pneuflex and other pneumatic accessories – push-in fittings, threaded fittings, reducers, flow control valves, silencers, plugs, blow guns and suction cups. Choose by tube diameter and connection thread.
TPC10-G02, TECHNOLINE: straight push-in fitting; tube Ø10mm, male thread G1/4. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPC04-M5C, TECHNOLINE: straight push-in fitting; tube Ø4mm, male thread M5. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPK06, TECHNOLINE, multi-way manifold for Ø6mm tube. A multi-way compressed air distributor for clear connection of consumer branches.
TPU03C, TECHNOLINE, miniature straight fitting for Ø3mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread. Miniature version.
TBPU06, TECHNOLINE, straight all-metal fitting for Ø6mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread. Metal body.
TPC03-M3C, TECHNOLINE: straight push-in fitting; tube Ø3mm, male thread M3. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPM04, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø4mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TPGJ12-08, TECHNOLINE, plug-in reducer Ø12mm→Ø8mm. A plug-in adapter into a push-in counterpart with a separate tube connection.
TPU04C, TECHNOLINE, miniature straight fitting for Ø4mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread. Miniature version.
TPD06-G02, TECHNOLINE: push-in T-fitting, thread in the run branch; tube Ø6mm, male thread G1/4. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPD08-G01, TECHNOLINE: push-in T-fitting, thread in the run branch; tube Ø8mm, male thread G1/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPL03-M3C, TECHNOLINE: elbow push-in fitting 90°; tube Ø3mm, male thread M3. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPB06-G02, TECHNOLINE: push-in T-fitting, thread in the bottom branch; tube Ø6mm, male thread G1/4. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPB08-G01, TECHNOLINE: push-in T-fitting, thread in the bottom branch; tube Ø8mm, male thread G1/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPC03-M6C, TECHNOLINE: straight push-in fitting; tube Ø3mm, male thread M6. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPL04-M3C, TECHNOLINE: elbow push-in fitting 90°; tube Ø4mm, male thread M3. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPC04-M3C, TECHNOLINE: straight push-in fitting; tube Ø4mm, male thread M3. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TSPPM-G06, TECHNOLINE: threaded plug with external hexagon. male thread G3/4, closing a hole, TSPPM version. Use in pneumatic distribution and verified mounting criteria.
TPV03C, TECHNOLINE, miniature elbow fitting 90° for Ø3mm tube. Change of line direction by 90° without a sharp tube bend right at the joint. Miniature version.
TPU06C, TECHNOLINE, miniature straight fitting for Ø6mm tube. Straight connection of two tubes; suitable for extending a pneumatic route without a thread. Miniature version.
TPL04-M5C, TECHNOLINE: elbow push-in fitting 90°; tube Ø4mm, male thread M5. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPL03-M5C, TECHNOLINE: elbow push-in fitting 90°; tube Ø3mm, male thread M5. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TBPC04-G01, TECHNOLINE: straight push-in fitting; tube Ø4mm, male thread G1/8. Push-in connection for pneumatics.
TBPC06-G01, TECHNOLINE: straight push-in fitting; tube Ø6mm, male thread G1/8. Push-in connection for pneumatics.
TPL10-G01, TECHNOLINE: elbow push-in fitting 90°; tube Ø10mm, male thread G1/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
I prezzi includono il contributo di riciclaggio.
Pneumatic accessories connect individual parts of the air circuit and help adapt its arrangement to a specific machine. When selecting, you need to know not only the part designation, but also both connected counterparts, the required function and operating conditions. A similar appearance of fittings or the same brand do not by themselves confirm interchangeability. This category is a signpost for line design, air distribution, flow adjustment and vacuum gripping.
Mechanical interface: record the full connection designation on both sides. For the tube, distinguish the outer and inner diameter; for the thread, its type, size and sealing method. Also check the space for mounting and service; the correct part may not be suitable for an installation that is too tight.
Function: draw where the medium should flow from and to. Connecting, branching, blanking, throttling and gripping are different tasks. For more complex accessories, compare the diagram and the full order code, not just the first part of the name.
Operating conditions: verify the permissible medium, pressure, temperature and environment for the specific version in the manufacturer's documentation. Assess use in vacuum separately. Do not derive the permitted range of the whole assembly from a parameter of one of its elements.
Let us consider four workstations, each with two separate lines. If each line forms one uninterrupted section, eight sections have a total of sixteen ends to connect. Dividing all eight sections into two parts adds eight intermediate fittings and sixteen more tube ends. This is our own inventory example, not a calculation of pressure loss or probability of leakage. It helps reveal missing counterparts and distinguish a spare piece from a part actually needed in the assembly.
Before intervention, shut down the equipment according to its instructions and secure it against unexpected movement. Disconnect lines only after safely removing pressure; for vacuum gripping, first secure the transported object. Take the mounting procedure, tightening and insertion check from the instructions of the specific accessory. After assembly, verify tightness, actual function and maintenance access during controlled commissioning.
In case of a leak, first determine its location, then check the counterpart, line size, seal condition and mechanical stress on the joint. In case of slow movement, monitor the whole supply and exhaust. Random replacement of one part without verifying the cause can leave the original problem in another part of the circuit.
A photo helps determine the shape. For ordering, however, add dimensions, exact connection, function and operating limitations. For a replacement, record the original code and also compare the counterpart.
Attach a simple circuit diagram, a list of connections, tube sizes and operating conditions. Mark what you already have and what should be part of the delivery; this makes the list and the compatibility check more precise.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.